Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1571) (remove)
Has Fulltext
- no (1571) (remove)
Language
- English (1571) (remove)
Document Type
- Article (1316)
- Conference Proceeding (135)
- Book (43)
- Part of a Book (43)
- Doctoral Thesis (18)
- Other (6)
- Patent (4)
- Preprint (3)
- Conference: Meeting Abstract (1)
- Habilitation (1)
Keywords
- LAPS (4)
- Natural language processing (4)
- CellDrum (3)
- Field-effect sensor (3)
- Light-addressable potentiometric sensor (3)
- Paired sample (3)
- hydrogen peroxide (3)
- impedance spectroscopy (3)
- Bacillus atrophaeus (2)
- Biocomposites (2)
- Boundary integral equations (2)
- Clustering (2)
- Conductive boundary condition (2)
- Empirical process (2)
- Force (2)
- Goodness-of-fit test (2)
- Incomplete data (2)
- Independence test (2)
- Information extraction (2)
- Iterative learning control (2)
- Limit analysis (2)
- Machine learning (2)
- Natural fibres (2)
- Parametric bootstrap (2)
- Polymer-matrix composites (2)
- Raman spectroscopy (2)
- Shakedown analysis (2)
- Simulation (2)
- Stiffness (2)
- Stress concentrations (2)
- Transmission eigenvalues (2)
- biopotential electrodes (2)
- constructive alignment (2)
- damage (2)
- examination (2)
- field-effect sensor (2)
- frequency mixing magnetic detection (2)
- humans (2)
- likelihood ratio test (2)
- locomotion (2)
- long-term retention (2)
- multimodal (2)
- muscle fascicle behavior (2)
- not identically distributed (2)
- practical learning (2)
- tobacco mosaic virus (TMV) (2)
- ultrasound (2)
- ultrasound imaging (2)
- (Bio)degradation (1)
- Acceleration (1)
- Achilles tendon (1)
- Active learning (1)
- Adaptive control (1)
- Afterload (1)
- Ageing (1)
- Agent-based modeling (1)
- Agent-based simulation (1)
- AlterG (1)
- Alzheimer's disease (1)
- Analytical models (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Architectural gear ratio (1)
- Assistive technology (1)
- Asymptotic efficiency (1)
- Asymptotic relative efficiency (1)
- Autolysis (1)
- Automatic control (1)
- Bacillus atrophaeus spores (1)
- Bacillus sp (1)
- Balance (1)
- Biomechanical simulation (1)
- Biomolecular logic gate (1)
- Biosolubilization (1)
- Bladder (1)
- Bone sawing (1)
- Booster Station (1)
- Bootstrap (1)
- Bootstrapping (1)
- Boundary integral equations, (1)
- Brownian Pillow (1)
- CNOT (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Categorial variable (1)
- Cell permeability (1)
- Cellular force (1)
- Cementoblast (1)
- Censored data (1)
- Chance constrained programming (1)
- Chemical images (1)
- Chemical imaging (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Circular Dichroism (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Co-managed care (1)
- Coal (1)
- Coat protein (1)
- Coefficient of ocular rigidity (1)
- Collective risk model (1)
- Comparative simulation (1)
- Competitiveness (1)
- Complex System (1)
- Complex-valued eigenvalues (1)
- Compliance (1)
- Compression (1)
- Computational biomechanics (1)
- Concomitant (1)
- Conductive Boundary Condition (1)
- Conservation laws (1)
- Constitutive model (1)
- Contractile tension (1)
- Contractility (1)
- Corneo-scleral shell (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- Cramér-von-Mises test (1)
- Cross border adjustment mechanism (1)
- Crámer–von-Mises distance (1)
- C–V method (1)
- DNA (1)
- DNA biosensor (1)
- DNA hybridization (1)
- DPA (dipicolinic acid) (1)
- Damage mechanics theory (1)
- Database (1)
- Decomposition (1)
- Deep learning (1)
- Dehydrogenase (1)
- Diaphorase (1)
- Differential tonometry (1)
- Dimensional splitting (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Discrete Optimization (1)
- Drug simulation (1)
- Dry surfaces (1)
- E-Mobility (1)
- EEG (1)
- EIS capacitive sensor (1)
- ES-FEM (1)
- Eigenvalue trajectories (1)
- Elderly (1)
- Electrolyte–insulator–semiconductor (1)
- Electromagnetism (1)
- Electromechanical modeling (1)
- Elemental (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Energy dispatch (1)
- Energy market (1)
- Energy market design (1)
- Energy-intensive industry (1)
- Entropy solution (1)
- Enzymatic biosensor (1)
- Enzyme biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme nanocarrier (1)
- Equivalence test (1)
- Esophageal Doppler monitor (1)
- Evolution of damage (1)
- Exponential Euler scheme, (1)
- Exponential time differencing (1)
- Extension fracture (1)
- Extension strain criterion (1)
- External knee adduction moments (1)
- Eyeball (1)
- FGF23 (1)
- FS-FEM (1)
- Fall prevention (1)
- Field effect (1)
- Field-effect biosensor (1)
- Field-effect device (1)
- Finite difference methods (1)
- Finite element analysis (1)
- Finite element analysis (FEA) (1)
- Finite element modelling (1)
- Floor prices (1)
- Focusing (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Frequency mixing magnetic detection (1)
- Functional Delta Method (1)
- Gamma distribution (1)
- Glaucoma (1)
- Glucose biosensor (1)
- Glucose oxidase (1)
- Gold nanoparticle (1)
- Goodness-of-fit tests for uniformity (1)
- Grid Computing (1)
- Ground-level falls (1)
- Growth modelling (1)
- H2 (1)
- Hadamard differentiability (1)
- Haemodialysis (1)
- Handbike (1)
- Heart tissue culture (1)
- Helmholtz equation (1)
- Heterostructure (1)
- Higher-order codes (1)
- Hodgkin–Huxley models (1)
- Hoeffding-Blum-Kiefer-Rosenblatt independence test (1)
- Homogenization (1)
- Hotelling’s T² test (1)
- Human-Computer interaction (1)
- Hydrogen peroxide (1)
- Hydrogenotrophic methanogens (1)
- Image Reconstruction (1)
- Impedance Spectroscopy (1)
- Impedance spectroscopy (1)
- Implicit methods (1)
- Induced pluripotent stem cells (1)
- Information Extraction (1)
- Inotropic compounds (1)
- Instruments (1)
- Integrated empirical distribution (survival) function (1)
- Interior Neumann eigenvalues (1)
- Interior transmission eigenvalues (1)
- Interior transmission problem (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse Scattering (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Inverse scattering (1)
- Inverse spectral problem (1)
- Ion channels (1)
- Kinetic energy (1)
- Klotho (1)
- Knee (1)
- LPS (1)
- Lab-on-Chip (1)
- Label-free detection (1)
- Langevin theory (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- Light-addressable Potentiometric Sensor (1)
- Lipopolysaccharide (1)
- Liver (1)
- Load modeling (1)
- Long COVID (1)
- MOS (1)
- Magnetic nanoparticles (1)
- Manipulated variables (1)
- Marginal homogeneity (1)
- Marginal homogeneity test (1)
- Market modeling (1)
- Matrix exponential (1)
- Measurement (1)
- Mechanical simulation (1)
- Mechanotransduction (1)
- Metascintillator (1)
- Methane (1)
- Methanogenesis (1)
- Microbial adhesion (1)
- Microcirculation (1)
- Micromagnetic simulation (1)
- Mild cognitive impairment (1)
- Mobility (1)
- Mobility tests (1)
- Mobility transition (1)
- Mohr–Coulomb criterion (1)
- Monotone methods (1)
- Multi-criteria decision analysis (1)
- Multi-dimensional partial differential equations (1)
- Multi-sample problem (1)
- Multianalyte detection (1)
- Multimode failure (1)
- Multiple TOF kernels (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Muscle fibers (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NONOate (1)
- Natural Language Processing (1)
- Natural language understanding (1)
- Negative impedance convertor (1)
- Neural Network (1)
- Niacin (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Non-linear optimization (1)
- Non-parallel fissures (1)
- Nonequilibrium dynamics (1)
- Nonlinear Dynamics (1)
- Nonlinear PDEs (1)
- Nonlinear eigenvalue problems (1)
- Nucleus Pulposus (1)
- Numerical inversion of Laplace transforms (1)
- Numerical linear algebra (1)
- Numerics (1)
- O2 plasma (1)
- Ocular blood flow (1)
- Open Data (1)
- Open source (1)
- Organic light-emitting diode display (1)
- PTH (1)
- Parabolic SPDEs (1)
- Paralympic sport (1)
- Passive stretching (1)
- Pelvic floor dysfunction (1)
- Pelvic muscle (1)
- Penicillin (1)
- Pharmacology (1)
- Phosphate (1)
- Physiology (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Post-COVID-19 syndrome (1)
- Potential theory (1)
- Potentiometry (1)
- Preference assessment (1)
- Pressure-volume relationship (1)
- Process model (1)
- Product-integration (1)
- Profile Extraction (1)
- Profile extraction (1)
- Proximal humerus fracture (1)
- Pulsations (1)
- Pump System (1)
- Query learning (1)
- RVA (1)
- Reaction-diffusion systems (1)
- Real distinct pole (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Reconstruction (1)
- Refining (1)
- Regionalization (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Relation classification (1)
- Reliability analysis (1)
- Reliability of structures (1)
- Renewable energy sources (1)
- Reproducible research (1)
- Resampling test (1)
- Resolvent Operator (1)
- Resonance-mode measurement (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Riboflavin (1)
- Robotic rehabilitation (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- Sampling methods (1)
- ScaLAPACK (1)
- Semi-parametric random censorship model (1)
- Septic cardiomyopathy (1)
- Simultaneous determination (1)
- Sleep EEG (1)
- Sn₃O₄ (1)
- Source term (1)
- Spleen (1)
- Steel industry (1)
- Sterilisation process (1)
- Stochastic programming (1)
- Surface microorganisms (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Survival analysis (1)
- Swabbing (1)
- TMV adsorption (1)
- TOF PET (1)
- Ta₂O₅ gate (1)
- Technical Operations Research (TOR) (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tension (1)
- Text Mining (1)
- Text mining (1)
- Thiamine (1)
- Time-series (1)
- Tinetti test (1)
- Tobacco mosaic virus (1)
- Tobacco mosaic virus (TMV) (1)
- Training (1)
- Transmission Eigenvalues (1)
- Trustworthy artificial intelligence (1)
- Uniaxial compression test (1)
- Ureter (1)
- Vapnik–Čhervonenkis class (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Velocity (1)
- Visual field asymmetry (1)
- Vitamin A (1)
- Vitamin B (1)
- Vitamin D (1)
- Volterra integral equation (1)
- Volume of confidence regions (1)
- Volume status (1)
- Volumes of confidence regions (1)
- Workflow (1)
- Workflow Orchestration (1)
- XML (1)
- XOR (1)
- access control (1)
- acetoin (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- allocation (1)
- anaesthetic complications (1)
- anisotropy (1)
- annealing (1)
- aortic perfusion (1)
- aquaculture (1)
- artificial olfactory image (1)
- asymptotic relative efficiency (1)
- authorization (1)
- barium strontium titanate (1)
- biaxial tensile experiment (1)
- biomechanics (1)
- biosensor (1)
- biosensors (1)
- bootstrap (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive field-effect biosensor (1)
- capacitive field-effect sensor (1)
- carbonized rice husk (1)
- cardiomyocyte biomechanics (1)
- catalytic metal (1)
- cell aerosolization (1)
- cell atomization (1)
- central symmetry test (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- chemical sensor (1)
- chip-based sensor setup (1)
- cognitive impairment (1)
- community dwelling (1)
- complete block symmetry (1)
- computational fluid dynamics analysis (1)
- concrete (1)
- conditional excess distribution (1)
- conditional expectation principle (1)
- confidence interval (1)
- connective tissue (1)
- constitutive modeling (1)
- contactless conductivity sensor (1)
- containers (1)
- correlation (1)
- coupled Néel–Brownian relaxation dynamics (1)
- covariance principle (1)
- dental trauma (1)
- dialysis (1)
- difficult airway (1)
- distorted element (1)
- distribution strategy (1)
- double-lumen tube intubation (1)
- drop jump (1)
- eigensolvers (1)
- elastic scattering (1)
- electrical conductivity of liquids (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electromyography (1)
- electronic nose (1)
- endoluminal (1)
- endospores (1)
- energy absorption (1)
- energy dissipation (1)
- engines (1)
- enzymatic (bio)degradation (1)
- enzyme cascade (1)
- enzyme immobilization (1)
- exchangeability test (1)
- extracorporeal membrane oxygenation (1)
- fatty acid (1)
- field-effect structure (1)
- force generation (1)
- forecast (1)
- forehead EEG (1)
- framework (1)
- frequency mixing (1)
- functional data (1)
- gait (1)
- gas sensor (1)
- glucose oxidase (GOx) (1)
- goodness-of-fit test (1)
- grid computing (1)
- healthy aging (1)
- heavy metals (1)
- hiPS cardiomyocytes (1)
- high-intensity exercise (1)
- high-k material (1)
- history (1)
- horseradish peroxidase (HRP) (1)
- huge dimensional data (1)
- humic acid (1)
- hydroxylation (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- immobilization (1)
- in-ear EEG (1)
- in-situ monitoring (1)
- independence test (1)
- intraclass correlation coefficient (1)
- key performance indicators (1)
- lable-free detection (1)
- libraries (1)
- light-addressable potentiometric sensor (1)
- light-addressing technologies (1)
- lignite (1)
- limit analysis (1)
- lipopolysaccharide (1)
- magnetic actuation (1)
- magnetic beads (1)
- magnetic biosensing (1)
- magnetic nanoparticles (1)
- magnetic relaxation (1)
- magnetic sandwich immunoassay (1)
- magnetic sensing (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- mechanical buffer (1)
- metal-oxide-semiconductor structure (1)
- metathesis (1)
- method of fundamental solutions (1)
- microfluidics (1)
- micromagnetic simulation (1)
- multi-functional material (1)
- multinomial distribution (1)
- multiparametric immunoassays (1)
- multivariate normal distribution (1)
- muscle mechanics (1)
- nanobelts (1)
- non-simplex S-FEM elements (1)
- novel photoexcitation method (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organosilanes (1)
- overload (1)
- parabolic flight (1)
- performance analysis (1)
- performance testing (1)
- physiology (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- poly(d, l-lactic acid) (1)
- polyamide (1)
- polyester (1)
- portfolio risk (1)
- prevention (1)
- provenance (1)
- psychosocial (1)
- random effects (1)
- random effects meta-regression model (1)
- rehabilitation (1)
- reliability of structures (1)
- renewable resources (1)
- resource management (1)
- retinal microvasculature (1)
- retinal vessels (1)
- running (1)
- sEMG (1)
- sarcomere operating length (1)
- scanned light pulse technique (1)
- scheduling (1)
- security (1)
- sensors (1)
- separable Hilbert space (1)
- series elastic element behavior (1)
- shakedown analysis (1)
- shoulder (1)
- silanization (1)
- simulation (1)
- smooth muscle contraction (1)
- spatial resolution (1)
- sprint start (1)
- standard error of measurement (1)
- sterilisation (1)
- sterilization (1)
- sterilization conditions (1)
- stiffness (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- superparamagnetic bead (1)
- superparamagnetic nanoparticles (1)
- surface functionalization (1)
- surface modification (1)
- survival (1)
- synchronization (1)
- temperature (1)
- tendon rupture (1)
- test-retest reliability (1)
- thermometry (1)
- tilted constant illumination (1)
- training simulator (1)
- tri-lineage differentiation (1)
- turnip vein clearing virus (TVCV) (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- uniformly most powerful invariant test (1)
- unloading (1)
- videolaryngoscopy (1)
- virgin passive (1)
- virtual reality (1)
- viscoelasticity (1)
- visualization (1)
- walking (1)
- walking gait (1)
- workflow (1)
- workflow management software (1)
Bonding of polymer-based microfluidics to polymer substrates still poses a challenge for Lab-On-a-Chip applications. Especially, when sensing elements are incorporated, patterned deposition of adhesives with curing at ambient conditions is required. Here, we demonstrate a fabrication method for fully printed microfluidic systems with sensing elements using inkjet and stereolithographic 3D-printing.
In this study, we describe the manufacturing and characterization of silk fibroin membranes derived from the silkworm Bombyx mori. To date, the dissolution process used in this study has only been researched to a limited extent, although it entails various potential advantages, such as reduced expenses and the absence of toxic chemicals in comparison to other conventional techniques. Therefore, the aim of this study was to determine the influence of different fibroin concentrations on the process output and resulting membrane properties. Casted membranes were thus characterized with regard to their mechanical, structural and optical assets via tensile testing, SEM, light microscopy and spectrophotometry. Cytotoxicity was evaluated using BrdU, XTT, and LDH assays, followed by live–dead staining. The formic acid (FA) dissolution method was proven to be suitable for the manufacturing of transparent and mechanically stable membranes. The fibroin concentration affects both thickness and transparency of the membranes. The membranes did not exhibit any signs of cytotoxicity. When compared to other current scientific and technical benchmarks, the manufactured membranes displayed promising potential for various biomedical applications. Further research is nevertheless necessary to improve reproducible manufacturing, including a more uniform thickness, less impurity and physiological pH within the membranes.
To gain insight on chemical sterilization processes, the influence of temperature (up to 70 °C), intense green light, and hydrogen peroxide (H₂O₂) concentration (up to 30% in aqueous solution) on microbial spore inactivation is evaluated by in-situ Raman spectroscopy with an optical trap. Bacillus atrophaeus is utilized as a model organism. Individual spores are isolated and their chemical makeup is monitored under dynamically changing conditions (temperature, light, and H₂O₂ concentration) to mimic industrially relevant process parameters for sterilization in the field of aseptic food processing. While isolated spores in water are highly stable, even at elevated temperatures of 70 °C, exposure to H₂O₂ leads to a loss of spore integrity characterized by the release of the key spore biomarker dipicolinic acid (DPA) in a concentration-dependent manner, which indicates damage to the inner membrane of the spore. Intensive light or heat, both of which accelerate the decomposition of H₂O₂ into reactive oxygen species (ROS), drastically shorten the spore lifetime, suggesting the formation of ROS as a rate-limiting step during sterilization. It is concluded that Raman spectroscopy can deliver mechanistic insight into the mode of action of H₂O₂-based sterilization and reveal the individual contributions of different sterilization methods acting in tandem.
Introduction
In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration.
Materials and methods
Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer’s classification was used to analyse the fractures.
Results
In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities.
Conclusion
A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education.
Influence of refrigerated storage on tensile mechanical properties of porcine liver and spleen
(2015)
Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs
(2012)
The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines.
BACKGROUND: Muscle stretch reflexes are widely used to examine neural muscle function. The knowledge of reflex response in muscles crossing the shoulder is limited. OBJECTIVE: To quantify reflex modulation according to various subject postures and different procedures of muscle pre-activation steering. METHODS: Thirteen healthy male participants performed two sets of external shoulder rotation stretches in various positions and with different procedures of muscle pre-activation steering on an isokinetic dynamometer over a range of two different pre-activation levels. All stretches were applied with a dynamometer acceleration of 104∘/s2 and a velocity of 150∘/s. Electromyographical response was measured via sEMG. RESULTS: Consistent reflexive response was observed in all tested muscles in all experimental conditions. The reflex elicitation rate revealed a significant muscle main effect (F (5,288) = 2.358, ρ= 0.040; η2= 0.039; f= 0.637) and a significant test condition main effect (F (1,288) = 5.884, ρ= 0.016; η2= 0.020; f= 0.143). Reflex latency revealed a significant muscle pre-activation level main effect (F (1,274) = 5.008, ρ= 0.026; η2= 0.018; f= 0.469). CONCLUSION: Muscular reflexive response was more consistent in the primary internal rotators of the shoulder. Supine posture in combination with visual feedback of muscle pre-activation level enhanced the reflex elicitation rate.
Background: One of the most prominent neurobiological models of alexithymia assumes an altered function of the anterior cingulate cortex (ACC) as the crucial neural correlate of alexithymia. So far functional imaging studies have yielded inconclusive results. Therefore, we tested this hypothesis in healthy alexithymics and nonalexithymics in an event-related fMRI study.
Methods: Thirty high- and 30 low-alexithymic right-handed male subjects (selected by the 20-item Toronto Alexithymia Scale, TAS-20) were investigated with event-related fMRI using a picture viewing paradigm. The stimuli consisted of happy, fearful and neutral facial expressions (Ekman-Friesen) as well as positive, negative and neutral pictures from the International Affective Picture System.
Results: Contrasting the high-alexithymic with the low-alexithymic group we observed increased activation of the supragenual ACC for different emotional valences as well as for different emotional stimuli. Moreover, there was a positive correlation of the ACC with the individual TAS-20 scores but no correlations with the individual Beck Depression Inventory scores. Additionally, there was no difference in activity of the amygdala.
Conclusions: We demonstrated that the supragenual ACC is constantly activated more strongly in alexithymic subjects and that this activation is related to the symptoms of alexithymia and not to associated symptoms such as depression. Therefore, our findings support the hypothesis of an altered function of the ACC in alexithymia.
The ideal combination among biomolecules and nanomaterials is the key for reaching biosensing units with high sensitivity. The challenge, however, is to find out a stable and sensitive film architecture that can be incorporated on the sensor’s surface. In this paper, we report on the benefits of incorporating a layer-by-layer (LbL) nanofilm of polyamidoamine (PAMAM) dendrimer and carbon nanotubes (CNTs) on capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors for detecting urea. Three sensor arrangements were studied in order to investigate the adequate film architecture, involving the LbL film with the enzyme urease: (i) urease immobilized directly onto a bare EIS [EIS-urease] sensor; (ii) urease atop the LbL film over the EIS [EIS-(PAMAM/CNT)-urease] sensor; and (iii) urease sandwiched between the LbL film and another CNT layer [EIS-(PAMAM/CNT)-urease-CNT]. The surface morphology of all three urea-based EIS biosensors was investigated by atomic force microscopy (AFM), while the biosensing abilities were studied by means of capacitance–voltage (C/V) and dynamic constant-capacitance (ConCap) measureaments at urea concentrations ranging from 0.1 mM to 100 mM. The EIS-urease and EIS-(PAMAM/CNT)-urease sensors showed similar sensitivity (∼18 mV/decade) and a nonregular signal behavior as the urea concentration increased. On the other hand, the EIS-(PAMAM/CNT)-urease-CNT sensor exhibited a superior output signal performance and higher sensitivity of about 33 mV/decade. The presence of the additional CNT layer was decisive to achieve a urea based EIS sensor with enhanced properties. Such sensitive architecture demonstrates that the incorporation of an adequate hybrid enzyme-nanofilm as sensing unit opens new prospects for biosensing applications using the field-effect sensor platform.
Learning- and memory-related processes are thought to result from dynamic interactions in large-scale brain networks that include lateral and mesial structures of the temporal lobes. We investigate the impact of incidental and intentional learning of verbal episodic material on functional brain networks that we derive from scalp-EEG recorded continuously from 33 subjects during a neuropsychological test schedule. Analyzing the networks' global statistical properties we observe that intentional but not incidental learning leads to a significantly increased clustering coefficient, and the average shortest path length remains unaffected. Moreover, network modifications correlate with subsequent recall performance: the more pronounced the modifications of the clustering coefficient, the higher the recall performance. Our findings provide novel insights into the relationship between topological aspects of functional brain networks and higher cognitive functions.
In-beam study of ¹⁴⁵ Gd
(1979)
In-beam study of ¹⁴⁴ Gd
(1978)
In-beam study of ¹⁴⁴ Gd
(1978)
In-beam study of ¹⁴⁴ Gd
(1977)
In-beam study of ¹⁴³ Eu
(1988)
Tumour cell death can be evaluated in the living mouse by externally measuring the rate of loss of tumour-bound DNA tracer. By sequentially labelling the tumour-bearing animals with ¹²⁵IUdR and ¹³¹IUdR 50 h apart, the average tumour cells at the time of the second injection are labelled by ¹²⁵IUdR and the euoxic tumour cells are specifically labelled with ¹³¹IUdR. Tumour treatment at this stage of labelling permits the observation of the reaction of euoxic cells and average tumour cells and finally yields data on hypoxic cells and thus on the oxygen enhancement ratio. This information adds to results from tumour control and growth delay.
With this technique effects were analysed of 60-Co γ-rays, cyclotron neutrons (E = 6 MeV), misonidazole (500 mg/kg body wt) and hyperthermia (42°C water-bath), or combinations of these.
Misonidazole (15 min before irradiation) altered the oxygen enhancement ratio by a factor of 1·5 for γ-rays and of 1·1 for neutrons; when evaluated from tumour-growth delay and TCD-50 misonidazole gave a dose modifying factor of 1·47 for γ-rays and of 1·2-1·3 for neutrons.
Based on percentage tumour regression 100 days after treatment, the enhancement ratio from hyperthermia (after irradiation) was 2·75 for γ-rays (at 10 Gray) and 2·2 for neutrons (at 3·2 Gray). For neutrons combined with misonidazole and hyperthermia the ratio was 2·4.
These results demonstrate that effects of neutron irradiation may be modified by electron-affinic substances and/or hyperthermia.
Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential.