Refine
Year of publication
- 2001 (106) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (48)
- INB - Institut für Nano- und Biotechnologien (39)
- Fachbereich Elektrotechnik und Informationstechnik (20)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Energietechnik (11)
- Fachbereich Luft- und Raumfahrttechnik (6)
- Fachbereich Wirtschaftswissenschaften (5)
- Fachbereich Maschinenbau und Mechatronik (2)
- ECSM European Center for Sustainable Mobility (1)
- Fachbereich Gestaltung (1)
Language
- English (106) (remove)
Document Type
- Article (88)
- Conference Proceeding (12)
- Book (6)
Keywords
- Einspielen <Werkstoff> (2)
- Blitzschutz (1)
- Einspielanalyse (1)
- Erneuerbare Energien (1)
- FEM (1)
- Finite-Elemente-Methode (1)
- Hybridsystem (1)
- Lightning protection (1)
- Materialermüdung (1)
- Renewable energy (1)
Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS?
(2001)
Novel concepts for flow-rate and flow-direction determination by means of pH-sensitive ISFETs
(2001)
The load-carrying capacity or the safety against plastic limit states are the central questions in the design of structures and passive components in the apparatus engineering. A precise answer is most simply given by limit and shakedown analysis. These methods can be based on static and kinematic theorems for lower and upper bound analysis. Both may be formulated as optimization problems for finite element discretizations of structures. The problems of large-scale analysis and the extension towards realistic material modelling will be solved in a European research project. Limit and shakedown analyses are briefly demonstrated with illustrative examples.
Lightning protection design of a renewable energy hybrid-system without power mains connection
(2001)
Lightning protection design of a renewable energy hybrid-system without power mains connection
(2001)
In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.
Laserwelding with fillerwire
(2001)
Knowledge Management
(2001)