Refine
Year of publication
- 2000 (245) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- Fachbereich Wirtschaftswissenschaften (37)
- Fachbereich Energietechnik (35)
- INB - Institut für Nano- und Biotechnologien (35)
- Fachbereich Elektrotechnik und Informationstechnik (34)
- Fachbereich Luft- und Raumfahrttechnik (18)
- Fachbereich Bauingenieurwesen (17)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Maschinenbau und Mechatronik (12)
- Solar-Institut Jülich (6)
Document Type
- Article (173)
- Book (42)
- Conference Proceeding (19)
- Part of a Book (4)
- Doctoral Thesis (3)
- Patent (2)
- Report (1)
- Review (1)
Keywords
- Einspielen <Werkstoff> (3)
- Finite-Elemente-Methode (3)
- FEM (2)
- Multimediamarkt (2)
- limit load (2)
- Abluft (1)
- Aluminium (1)
- Ansaugsystem (1)
- Basis Reduktion (1)
- Basis reduction (1)
Books Reviewed - European Democratization since 1800 edited by J. Garrard, V. Tolz and R. White
(2000)
Beryllium doped low-temperature-grown MBE GaAs: material for photomixing in the THz frequency range
(2000)
Limit and shakedown analysis are effective methods for assessing the load carrying capacity of a given structure. The elasto–plastic behavior of the structure subjected to loads varying in a given load domain is characterized by the shakedown load factor, defined as the maximum factor which satisfies the sufficient conditions stated in the corresponding static shakedown theorem. The finite element dicretization of the problem may lead to very large convex optimization. For the effective solution a basis reduction method has been developed that makes use of the special problem structure for perfectly plastic material. The paper proposes a modified basis reduction method for direct application to the two-surface plasticity model of bounded kinematic hardening material. The considered numerical examples show an enlargement of the load carrying capacity due to bounded hardening.
Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I&C-cables.
Abfallwirtschaft
(2000)