Refine
Year of publication
- 2006 (330) (remove)
Document Type
- Article (180)
- Conference Proceeding (94)
- Book (29)
- Patent (6)
- Part of a Book (5)
- Diploma Thesis (3)
- Lecture (3)
- Other (3)
- Course Material (2)
- Report (2)
- Master's Thesis (1)
- Part of Periodical (1)
- Working Paper (1)
Language
- German (166)
- English (160)
- Russian (2)
- Portuguese (1)
- Spanish (1)
Keywords
- Biosensor (23)
- CAD (3)
- Technische Mechanik (3)
- Bauingenieurwesen (2)
- Bauplanung (2)
- Führung (2)
- Leadership (2)
- Motivation (2)
- Rapid Prototyping (2)
- Rapid prototyping (2)
- Self-Leadership (2)
- biosensor (2)
- civil engineering (2)
- 3-nitrofluoranthene (1)
- 3D (1)
- ACCESS 2003 (1)
- ACCESS <Programm> (1)
- Aachen / Fachhochschule Aachen (1)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (1)
- Aachen University of Applied Sciences (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (75)
- Fachbereich Bauingenieurwesen (51)
- Fachbereich Wirtschaftswissenschaften (45)
- Fachbereich Luft- und Raumfahrttechnik (32)
- Fachbereich Energietechnik (29)
- Fachbereich Maschinenbau und Mechatronik (29)
- Fachbereich Elektrotechnik und Informationstechnik (27)
- IfB - Institut für Bioengineering (24)
- INB - Institut für Nano- und Biotechnologien (22)
- Fachbereich Chemie und Biotechnologie (17)
- Fachbereich Architektur (6)
- Solar-Institut Jülich (6)
- Fachbereich Gestaltung (4)
- Freshman Institute (3)
- Nowum-Energy (3)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (3)
- ECSM European Center for Sustainable Mobility (2)
- FH Aachen (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
- Sonstiges (1)
In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demonstrated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several additional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings.
Praktische Untersuchungen zum zeitlichen Übertragungs- und Bündelfehlerverhalten der IEEE 802.15.4
(2006)
In: Alfha.net / Sektion Bauingenieurwesen: 1. [Erster] Erfahrungsaustausch : Absolventen des Fachbereichs Bauingenieurwesens berichten. 13. Oktober 2006. S. 16-17 Der Umbau des Aachener Buschtunnels im Rahmen des europäischen Hochgeschwindigkeitsschienennetzes wird im sogenannten "Neuen Österreichischen Tunnelbauverfahren (NOeT)", also ein Ausbau in Kalotte, Strosse und Sohle durchgeführt.
In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD+, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results obtained by the spectrophotometric method were compared with the results obtained by the colourimetry, using pH indicators. The above-mentioned two methods will be used as references for potentiometric measurements of phenylalanine concentration.
Para Reiss, a avaliação de cada um dos 16 motivos vitais é a chave para não só entender o comportamento humano, como também para poder prevê-lo. Tal previsão é também a meta de cada ciência. Quando se quer saber a reação das pessoas, precisa-se primeiro descobrir, o que as pessoas realmente querem – e, então prever, que elas satisfarão esses desejos e necessidades em suas ações. As chances, que o Perfil Reiss oferece, resultam entre outras também, que aqui é possível pela primeira vez uma individualização total. Cerca de 6 bilhões de perfis individuais podem ser apresentados com o Perfil Reiss. Na combinação correta da formação e utilização da tipologia de um lado e da individualidade da conclusão de outro lado, está a força positiva desse instrumento.
Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations
(2006)
A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors.