Refine
Year of publication
- 2021 (43) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (43) (remove)
Has Fulltext
- no (43) (remove)
Language
- English (43) (remove)
Document Type
- Article (29)
- Conference Proceeding (7)
- Part of a Book (2)
- Doctoral Thesis (2)
- Book (1)
- Other (1)
- Preprint (1)
Keywords
- constructive alignment (2)
- examination (2)
- long-term retention (2)
- multimodal (2)
- practical learning (2)
- AlterG (1)
- Bacillus sp (1)
- Biosolubilization (1)
- Bootstrap (1)
- Boundary integral equations (1)
- CellDrum (1)
- Coefficient of ocular rigidity (1)
- Corneo-scleral shell (1)
- Differential tonometry (1)
- EEG (1)
- Empirical process (1)
- Eyeball (1)
- Frequency mixing magnetic detection (1)
- Functional Delta Method (1)
- Glaucoma (1)
- Hadamard differentiability (1)
- Helmholtz equation (1)
- Impedance Spectroscopy (1)
- Interior Neumann eigenvalues (1)
- LPS (1)
- Langevin theory (1)
- Machine learning (1)
- Magnetic nanoparticles (1)
- Micromagnetic simulation (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Natural language processing (1)
- Nonequilibrium dynamics (1)
- Numerics (1)
- Ocular blood flow (1)
- Paired sample (1)
- Potential theory (1)
- Pressure-volume relationship (1)
- Process model (1)
- RVA (1)
- Septic cardiomyopathy (1)
- Simulation (1)
- Sleep EEG (1)
- Stiffness (1)
- TMV adsorption (1)
- Ta₂O₅ gate (1)
- Tendon Rupture (1)
- Vascular response (1)
- Visual field asymmetry (1)
- actin cytoskeleton (1)
- biopotential electrodes (1)
- capacitive field-effect sensor (1)
- cardiomyocyte biomechanics (1)
- drop jump (1)
- gait (1)
- humic acid (1)
- hyper-gravity (1)
- hypo-gravity (1)
- intraclass correlation coefficient (1)
- lignite (1)
- locomotion (1)
- muscle fascicle behavior (1)
- muscle mechanics (1)
- parabolic flight (1)
- plant virus detection (1)
- rehabilitation (1)
- running (1)
- sarcomere operating length (1)
- sensors (1)
- series elastic element behavior (1)
- shoulder (1)
- sprint start (1)
- standard error of measurement (1)
- stretch reflex (1)
- test-retest reliability (1)
- tobacco mosaic virus (TMV) (1)
- ultrasonography (1)
- ultrasound imaging (1)
- unloading (1)
- walking (1)
Rehabilitative body weight supported gait training aims at restoring walking function as a key element in activities of daily living. Studies demonstrated reductions in muscle and joint forces, while kinematic gait patterns appear to be preserved with up to 30% weight support. However, the influence of body weight support on muscle architecture, with respect to fascicle and series elastic element behavior is unknown, despite this having potential clinical implications for gait retraining. Eight males (31.9 ± 4.7 years) walked at 75% of the speed at which they typically transition to running, with 0% and 30% body weight support on a lower-body positive pressure treadmill. Gastrocnemius medialis fascicle lengths and pennation angles were measured via ultrasonography. Additionally, joint kinematics were analyzed to determine gastrocnemius medialis muscle–tendon unit lengths, consisting of the muscle's contractile and series elastic elements. Series elastic element length was assessed using a muscle–tendon unit model. Depending on whether data were normally distributed, a paired t-test or Wilcoxon signed rank test was performed to determine if body weight supported walking had any effects on joint kinematics and fascicle–series elastic element behavior. Walking with 30% body weight support had no statistically significant effect on joint kinematics and peak series elastic element length. Furthermore, at the time when peak series elastic element length was achieved, and on average across the entire stance phase, muscle–tendon unit length, fascicle length, pennation angle, and fascicle velocity were unchanged with respect to body weight support. In accordance with unchanged gait kinematics, preservation of fascicle–series elastic element behavior was observed during walking with 30% body weight support, which suggests transferability of gait patterns to subsequent unsupported walking.
The hot spots conjecture is only known to be true for special geometries. This paper shows numerically that the hot spots conjecture can fail to be true for easy to construct bounded domains with one hole. The underlying eigenvalue problem for the Laplace equation with Neumann boundary condition is solved with boundary integral equations yielding a non-linear eigenvalue problem. Its discretization via the boundary element collocation method in combination with the algorithm by Beyn yields highly accurate results both for the first non-zero eigenvalue and its corresponding eigenfunction which is due to superconvergence. Additionally, it can be shown numerically that the ratio between the maximal/minimal value inside the domain and its maximal/minimal value on the boundary can be larger than 1 + 10− 3. Finally, numerical examples for easy to construct domains with up to five holes are provided which fail the hot spots conjecture as well.