Article
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1361)
- INB - Institut für Nano- und Biotechnologien (503)
- Fachbereich Chemie und Biotechnologie (473)
- Fachbereich Elektrotechnik und Informationstechnik (414)
- IfB - Institut für Bioengineering (412)
- Fachbereich Energietechnik (361)
- Fachbereich Luft- und Raumfahrttechnik (254)
- Fachbereich Maschinenbau und Mechatronik (152)
- Fachbereich Wirtschaftswissenschaften (116)
- Fachbereich Bauingenieurwesen (69)
- Solar-Institut Jülich (43)
- ECSM European Center for Sustainable Mobility (32)
- Institut fuer Angewandte Polymerchemie (21)
- Sonstiges (21)
- Nowum-Energy (18)
- Freshman Institute (17)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (15)
- Fachbereich Architektur (12)
- Fachbereich Gestaltung (12)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (5)
- IMP - Institut für Mikrowellen- und Plasmatechnik (3)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (2)
- Kommission für Forschung und Entwicklung (2)
- FH Aachen (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
- Kommission für Planung und Finanzen (1)
- Senat (1)
Language
- English (3288) (remove)
Document Type
- Article (3288) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- additive manufacturing (4)
- biosensors (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
Fatigue analyses are conducted with the aim of verifying that thermal ratcheting is limited. To this end it is important to make a clear distintion between the shakedown range and the ratcheting range (continuing deformation). As part of an EU-supported research project, experiments were carried out using a 4-bar model. The experiment comprised a water-cooled internal tube, and three insulated heatable outer test bars. The system was subjected to alternating axial forces, superimposed with alternating temperatures at the outer bars. The test parameters were partly selected on the basis of previous shakedown analyses. During the test, temperatures and strains were measured as a function of time. The loads and the resulting stresses were confirmed on an ongoing basis during performance of the test, and after it. Different material models were applied for this incremental elasto-plastic analysis using the ANSYS program. The results of the simulation are used to verify the FEM-based shakedown analysis.
The load-carrying capacity or the safety against plastic limit states are the central questions in the design of structures and passive components in the apparatus engineering. A precise answer is most simply given by limit and shakedown analysis. These methods can be based on static and kinematic theorems for lower and upper bound analysis. Both may be formulated as optimization problems for finite element discretizations of structures. The problems of large-scale analysis and the extension towards realistic material modelling will be solved in a European research project. Limit and shakedown analyses are briefly demonstrated with illustrative examples.
An ISFET-based penicillin sensor with high sensitivity, low detection limit and long lifetime
(2001)
Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS?
(2001)
Novel concepts for flow-rate and flow-direction determination by means of pH-sensitive ISFETs
(2001)
Outlier Robust Estimation of an Euler Equation Investment Model with German Firm Level Panel Data
(2002)
Macroporous silicon has been etched from n-type Si, using a vertical etching cell where no rear side contact on the silicon wafer is necessary. The resulting macropores have been characterised by means of Scanning Electron Microscopy (SEM). After etching, SiO₂ was thermally grown on the top of the porous silicon as an insulating layer and Si₃N₄ was deposited by means of Low Pressure Chemical Vapour Deposition (LPCVD) as transducer material to fabricate a capacitive pH sensor. In order to prepare porous biosensors, the enzyme penicillinase has been additionally immobilised inside the porous structure. Electrochemical measurements of the pH sensor and the biosensor with an Electrolyte/Insulator/Semiconductor (EIS) structure have been performed in the Capacitance/Voltage (C/V) and Constant capacitance (ConCap) mode.