Article
Refine
Year of publication
- 2010 (177) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (60)
- IfB - Institut für Bioengineering (31)
- Fachbereich Wirtschaftswissenschaften (23)
- Fachbereich Elektrotechnik und Informationstechnik (22)
- INB - Institut für Nano- und Biotechnologien (22)
- Fachbereich Energietechnik (17)
- Fachbereich Chemie und Biotechnologie (15)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Bauingenieurwesen (9)
- Fachbereich Maschinenbau und Mechatronik (8)
Has Fulltext
- no (177) (remove)
Document Type
- Article (177) (remove)
Keywords
Comparison of Intravenous Immunoglobulins for Naturally Occurring Autoantibodies against Amyloid-β
(2010)
Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry
(2010)
Normative Regulations
(2010)
During the development process of a complex technical product, one widely used and important technique is accelerated testing where the applied stress on a component is chosen to exceed the reference stress, i.e. the stress encountered in field operation, in order to reduce the time to failure. For that, the reference stress has to be known. Since a complex technical product may fail regarding numerous failure modes, stress in general is highly dimensional rather than scalar. In addition, customers use their products individually, i.e. field operation should be described by a distribution rather than by one scalar stress value. In this paper, a way to span the customer usage space is shown. It allows the identification of worst case reference stress profiles in significantly reduced dimensions with minimal loss of information. The application example shows that even for a complex product like a combustion engine, stress information can be compressed significantly. With low measurement effort it turned out that only three reference stress cycles were sufficient to cover a broad range of customer stress variety.
Two- and three-dimensional avalanche dynamics models are being increasingly used in hazard-mitigation studies. These models can provide improved and more accurate results for hazard mapping than the simple one-dimensional models presently used in practice. However, two- and three-dimensional models generate an extensive amount of output data, making the interpretation of simulation results more difficult. To perform a simulation in three-dimensional terrain, numerical models require a digital elevation model, specification of avalanche release areas (spatial extent and volume), selection of solution methods, finding an adequate calculation resolution and, finally, the choice of friction parameters. In this paper, the importance and difficulty of correctly setting up and analysing the results of a numerical avalanche dynamics simulation is discussed. We apply the two-dimensional simulation program RAMMS to the 1968 extreme avalanche event In den Arelen. We show the effect of model input variations on simulation results and the dangers and complexities in their interpretation.
Numerical avalanche dynamics models have become an essential part of snow engineering. Coupled with field observations and historical records, they are especially helpful in understanding avalanche flow in complex terrain. However, their application poses several new challenges to avalanche engineers. A detailed understanding of the avalanche phenomena is required to construct hazard scenarios which involve the careful specification of initial conditions (release zone location and dimensions) and definition of appropriate friction parameters. The interpretation of simulation results requires an understanding of the numerical solution schemes and easy to use visualization tools. We discuss these problems by presenting the computer model RAMMS, which was specially designed by the SLF as a practical tool for avalanche engineers. RAMMS solves the depth-averaged equations governing avalanche flow with accurate second-order numerical solution schemes. The model allows the specification of multiple release zones in three-dimensional terrain. Snow cover entrainment is considered. Furthermore, two different flow rheologies can be applied: the standard Voellmy–Salm (VS) approach or a random kinetic energy (RKE) model, which accounts for the random motion and inelastic interaction between snow granules. We present the governing differential equations, highlight some of the input and output features of RAMMS and then apply the models with entrainment to simulate two well-documented avalanche events recorded at the Vallée de la Sionne test site.
Numerical solution of the heat equation with non-linear, time derivative-dependent source term
(2010)
The mathematical modeling of heat conduction with adsorption effects in coated metal structures yields the heat equation with piecewise smooth coefficients and a new kind of source term. This term is special, because it is non-linear and furthermore depends on a time derivative. In our approach we reformulated this as a new problem for the usual heat equation, without source term but with a new non-linear coefficient. We gave an existence and uniqueness proof for the weak solution of the reformulated problem. To obtain a numerical solution, we developed a semi-implicit and a fully implicit finite volume method. We compared these two methods theoretically as well as numerically. Finally, as practical application, we simulated the heat conduction in coated aluminum fibers with adsorption in the zeolite coating. Copyright © 2010 John Wiley & Sons, Ltd.
Lightning safety guidelines
(2010)
Purpose: Image analysis by the retinal vessel analyzer (RVA) observes retinal vessels in their dynamic state online noninvasively along a chosen vessel segment. It has been found that high-frequency diameter changes in the retinal artery blood column along the vessel increase significantly in anamnestically healthy volunteers with increasing age and in patients with glaucoma during vascular dilation. This study was undertaken to investigate whether longitudinal sections of the retinal artery blood column are altered in systemic hypertension.
Methods: Retinal arteries of 15 untreated patients with essential arterial hypertension (age, 50.9 ± 11.9 years) and of 15 age-matched anamnestically healthy volunteers were examined by RVA. After baseline assessment, a monochromatic luminance flicker (530–600 nm; 12.5 Hz; 20 s) was applied to evoke retinal vasodilation. Differences in amplitude and frequency of spatial artery blood column diameter change along segments (longitudinal arterial profiles) of 1 mm in length were measured and analyzed using Fourier transformation.
Results: In the control group, average reduced power spectra (ARPS) of longitudinal arterial profiles did not differ when arteries changed from constriction to dilation. In the systemic hypertension group, ARPS during constriction, baseline, and restoration were identical and differed from ARPS during dilation (P < 0.05). Longitudinal arterial profiles in both groups showed significant dissimilitude at baseline and restoration (P < 0.05).
Conclusions: The retinal artery blood column demonstrates microstructural alterations in systemic hypertension and is less irregular along the vessel axis during vessel dilation. These microstructural changes may be an indication of alterations in vessel wall rigidity, vascular endothelial function, and smooth muscle cells in this disease, leading to impaired perfusion and regulation.
Bilaterale stromale Hornhauttrübungen sind für den Augenarzt eine differenzialdiagnostische Herausforderung. Im folgenden Beitrag werden 2 Patieninnen (30 und 36 Jahre) mit unterschiedlich stark ausgeprägter stromaler diffuser Hornhauttrübung vorgestellt. Patientin 1 war kleinwüchsig (114 cm) und Patientin 2 normal groß (172 cm). Beide Patientinnen wiesen veränderte Gelenkstrukturen an Hand und Fußgelenken sowie diffuse stromale Hornhauttrübungen auf. Des Weiteren lagen eine Mitral- und Aorteninsuffizienz (Patientin 1) bzw. eine Aorteninsuffizienz (Patientin 2) vor. Die stromalen diffusen Hornhauttrübungen ließen im Zusammenhang mit den Gelenkveränderungen ein Scheie-Syndrom vermuten. Therapeutisch ist bei Patienten mit Visusminderung eine (lamelläre) Keratoplastik sinnvoll.