Refine
Year of publication
- 2015 (301) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (70)
- Fachbereich Wirtschaftswissenschaften (42)
- IfB - Institut für Bioengineering (40)
- Fachbereich Elektrotechnik und Informationstechnik (36)
- INB - Institut für Nano- und Biotechnologien (36)
- Fachbereich Luft- und Raumfahrttechnik (32)
- Fachbereich Chemie und Biotechnologie (30)
- Fachbereich Bauingenieurwesen (27)
- Fachbereich Maschinenbau und Mechatronik (26)
- Fachbereich Energietechnik (23)
Document Type
- Article (126)
- Conference Proceeding (92)
- Part of a Book (39)
- Book (22)
- Other (7)
- Report (7)
- Doctoral Thesis (5)
- Patent (2)
- Part of a Periodical (1)
Keywords
- Attitude dynamics (1)
- Booster Station (1)
- Carsharing (1)
- Charging stations (1)
- Discrete Optimisation (1)
- Discrete Optimization (1)
- E-carsharing (1)
- E-mobility (1)
- Efficiency (1)
- Electrical vehicle (1)
A sensor system for investigating (bio)degradationprocesses of polymers is presented. The system utilizes semiconductor field-effect sensors and is capable of monitoring the degradation process in-situ and in real-time. The degradation of the polymer poly(d,l-lactic acid) is exemplarily monitored in solutions with different pH value, pH-buffer solution containing the model enzyme lipase from Rhizomucormiehei and cell-culture medium containing supernatants from stimulated and non-stimulated THP-1-derived macrophages mimicking activation of the immune system.
An amperometric enzyme biosensor has been applied for the detection of adrenaline. The adrenaline biosensor has been prepared by modification of an oxygen electrode with the enzyme laccase that operates at a broad pH range between pH 3.5 to pH 8. The enzyme molecules were immobilized via cross-linking with glutaraldehyde. The sensitivity of the developed adrenaline biosensor in different pH buffer solutions has been studied.
LAPS are field-effect-based potentiometric sensors which are able to monitor analyte concentrations in a spatially resolved manner. Hence, a LAPS sensor system is a powerful device to record chemical imaging of the concentration of chemical species in an aqueous solution, chemical reactions, or the growth of cell colonies on the sensor surface, to record chemical images. In this work, multi-chamber 3D-printed structures made out of polymer (PP-ABS) were combined with LAPS chips to analyse differentially and simultaneously the metabolic activity of Escherichia coli K12 and Chinese hamster ovary (CHO) cells, and the responds of those cells to the addition of glucose solution.
A multi-functional device applying for the safe maintenance at high-altitude on wind turbines
(2015)
Allgemeines Steuerrecht
(2015)
Rugged terrain robot designs are important for field robotics missions. A number of commercial platforms are available, however, at an impressive price. In this paper, we describe the hardware and software component of a low-cost wheeled rugged-terrain robot. The robot is based on an electric children quad bike and is modified to be driven by wire. In terms of climbing properties, operation time and payload it can compete with some of the commercially available platforms, but at a far lower price.
Influence of refrigerated storage on tensile mechanical properties of porcine liver and spleen
(2015)
Detection of triacetone triperoxide using temperature cycled metal-oxide semiconductor gas sensors
(2015)
A concept for a new generation of an integrated multi-functional biosensor/actuator system is developed, which is based on biomolecular logic principles. Such a system is expected to be able to detect multiple biochemical input signals simultaneously and in real-time and convert them into electrical output signals with logical operations such as OR, AND, etc. The system can be designed as a closed-loop drug release device triggered by an enzyme logic gate, while the release of the drug induced by the actuator at the required dosage and timing will be controlled by an additional drug sensor. Thus, the system could help to make an accurate and specific diagnosis. The presented concept is exemplarily demonstrated by using an enzyme logic gate based on a glucose/glucose oxidase system, a temperature-responsive hydrogel mimicking the actuator function and an insulin (drug) sensor. In this work, the results of functional testing of individual amperometric glucose and insulin sensors as well as an impedimetric sensor for the detection of the hydrogel swelling/shrinking are presented.
A new microfluidic assembly method for semiconductor-based biosensors using 3D-printing technologies was proposed for a rapid and cost-efficient design of new sensor systems. The microfluidic unit is designed and printed by a 3D-printer in just a few hours and assembled on a light-addressable potentiometric sensor (LAPS) chip using a photo resin. The cell growth curves obtained from culturing cells within microfluidics-based LAPS systems were compared with cell growth curves in cell culture flasks to examine biocompatibility of the 3D-printed chips. Furthermore, an optimal cell culturing within microfluidics-based LAPS chips was achieved by adjusting the fetal calf serum concentrations of the cell culture medium, an important factor for the cell proliferation.
Manuelle Herstellung ist sozial fair, ökologisch nachhaltig und schafft qualitätsvolle Erzeugnisse! Vorbote für eine großformatige Rückkehr zum Handwerk und zur eigenhändigen Fertigung ist die Maker-Bewegung! – Solche Thesen begegnen uns gegenwärtig oft. Journalistische Texte, Filmdokumentationen, Werbung oder die Ästhetik von Produkten sind ihre Vehikel. Doch wie ist es um die Wiederbelebung des Handwerks tatsächlich bestellt? Und in welchem Verhältnis steht das Design – ein durch und durch industriebasiertes Berufsfeld – zu vorindustriellen Produktionsweisen? Diesen Fragen geht das vorliegende Buch ebenso auf den Grund wie der seit Beginn der Industrialisierung auftretenden Handwerksromantik. Es untersucht zudem, wie aktuelles Design die Sehnsucht nach dem Ursprünglichen mit formalen Kodes beantwortet und wie die visuellen Erscheinungsformen des Handgemachten ihre Wirkung freisetzen.
Thermal management in E-carsharing vehicles - preconditioning concepts of passenger compartments
(2015)
The issue of thermal management in electric vehicles includes the topics of drivetrain cooling and heating, interior temperature, vehicle body conditioning and safety. In addition to the need to ensure optimal thermal operating conditions of the drivetrain components (drive motor, battery and electrical components), thermal comfort must be provided for the passengers. Thermal comfort is defined as the feeling which expresses the satisfaction of the passengers with the ambient conditions in the compartment. The influencing factors on thermal comfort are the temperature and humidity as well as the speed of the indoor air and the clothing and the activity of the passengers, in addition to the thermal radiation and the temperatures of the interior surfaces. The generation and the maintenance of free visibility (ice- and moisture-free windows) count just as important as on-demand heating and cooling of the entire vehicle. A Carsharing climate concept of the innovative ec2go vehicle stipulates and allows for only seating areas used by passengers to be thermally conditioned in a close-to-body manner. To enable this, a particular feature has been added to the preconditioning of the Carsharing electric vehicle during the electric charging phase at the parking station.
Information and communication technology for integrated mobility concepts such as E-carsharing
(2015)
During the past decade attitude towards sharing things has changed extremely. Not just personal data is shared (e.g. in social networks) but also mobility. Together with the increased ecological awareness of the recent years, new mobility concepts have evolved. E-carsharing has become a symbol for these changes of attitude. The management of a shared car fleet, the energy management of electric mobility and the management of various carsharing users with individual likes and dislikes are just some of the major challenges of e-carsharing. Weaving it into integrated mobility concepts, this raises complexity even further. These challenges can only be overcome by an appropriate amount of well-shaped information available at the right place and time. In order to gather, process and share the required information, fleet cars have to be equipped with modern information and communication technology (ICT) and become so-called fully connected cars. Ensuring the usability of these ICT systems is another challenge that is often neglected, even though it is usability that makes carsharing comfortable, attractive and supports users’ new attitudes. By means of an integrated and consistent concept for human-machine interaction (HMI), the usability of such systems can be raised tremendously.
For a wide acceptance of E-Mobility, a well-developed charging infrastructure is needed. Conductive charging stations, which are today’s state of the art, are of limited suitability for urbanised areas, since they cause a significant diversification in townscape. Furthermore, they might be destroyed by vandalism. Besides for those urbanistic reasons, inductive charging stations are a much more comfortable alternative, especially in urbanised areas. The usage of conductive charging stations requires more or less bulky charging cables. The handling of those standardised charging cables, especially during poor weather conditions, might cause inconvenience, such as dirty clothing etc. Wireless charging does not require visible and vandalism vulnerable charge sticks. No wired connection between charging station and vehicle is needed, which enable the placement below the surface of parking spaces or other points of interest. Inductive charging seems to be the optimal alternative for E-Mobility, as a high power transfer can be realised with a manageable technical and financial effort. For a well-accepted and working public charging infrastructure in urbanised areas it is essential that the infrastructure fits the vehicles’ needs. Hence, a well-adjusted standardisation of the charging infrastructure is essential. This is carried out by several IEC (International Electrotechnical Commission) and national standardisation committees. To ensure an optimised technical solution for future’s inductive charging infrastructures, several field tests had been carried out and are planned in near future.
Geotechnik
(2015)
Abfallwirtschaft
(2015)
Siedlungswasserwirtschaft
(2015)
Nachfolgende Ausführungen und Berechnungsbeispiele beziehen sich auf Kapitel 19 Siedlungswasserwirtschaft im „Wendehorst: Bautechnische Zahlentafeln 35. Auflage 2015“ (abgekürzt: BZ). Für den Bau von Anlagen der Siedlungswasserwirtschaft sind ebenso die Grundlagen der Hydraulik zu berücksichtigen. Aus diesem Grunde sind auch die entsprechenden Ausführungen zur Hydraulik zu beachten.
Stahlbau
(2015)
Stahlbetonbau
(2015)
Das Kapitel Stahlbetonbau besteht aus einer Formelsammlung (Teil A) sowie einem Praxisbeispiel (Teil B). In dem Praxisbeispiel werden exemplarisch die erforderlichen Rechenschritte und Nachweise zur Bemessung im GZT und GZG nach Eurocode 2 [1] vorgestellt. Die Hinweise im Text beziehen sich, soweit nicht explizit erwähnt, auf Wendehorst, Bautechnische Zahlentafeln, 35. Auflage, „Stahlbeton- und Spannbetonbau nach Eurocode 2“ [2]. Die zum Praxisbeispiel zugehörigen Konstruktions- und Bewehrungszeichnungen stehen im Onlineportal zu diesem Buch zum kostenlosen Download bereit (siehe unter www.springer.com).
Wendehorst Beispiele aus der Baupraxis / Ulrich Vismann (Hrsg.). - 5., durchges. und aktualis. Aufl.
(2015)
Abfallwirtschaft
(2015)
Siedlungswasserwirtschaft
(2015)
Geotechnik
(2015)
In der nationalen und der europäischen Normung werden die geotechnischen Aufgaben zwecks Mindestanforderungen an Baugrunduntersuchung, rechnerische Nachweise und Überwachung der Ausführung in drei Klassen (Kategorien) eingeteilt. Sie richten sich nach der zu erwartenden Reaktion des Baugrundes, nach dem geotechnischen Schwierigkeitsgrad des Tragwerks und seiner Einflüsse auf die Umgebung.
In DIN 4020 wurde die Einteilung bezüglich Art und Umfang der geotechnischen Untersuchungen bereits verbindlich eingeführt.
Stahlbau
(2015)
Es ist zwischen Stählen bis S460 und solchen mit höherer Streckgrenze zu unterscheiden. Stähle bis S460 sind auch für die plastische Tragwerksberechnung nach dem Fließgelenkverfahren zugelassen. Bei Stählen oberhalb S460 bis S700 ist neben der elastischen eine nichtlineare plastische Tragwerksberechnung unter Berücksichtigung von Teilplastizierungen von Bauteilen in Fließzonen möglich.
Beton
(2015)
Wendehorst bautechnische Zahlentafeln / hrsg. von Ulrich Vismann. Ernst Biener ... - 35. Aufl.
(2015)
Konstruktion und Raumform im Kirchenbau der Moderne : Die Längsbinderkirchen von Hans Herkommer
(2015)
Wettbewerbsregeln (§§ 24-27)
(2015)
Poly(N-isopropylacrylamide) (PNIPAAm) hydrogel films with incorporated graphene oxide (GO) were developed and tested as light-stimulated actuators. GO dispersions were synthesized via Hummers method and characterized toward their optical properties and photothermal energy conversion. The hydrogels were prepared by means of photopolymerization. In addition, the influence of GO within the hydrogel network on the lower critical solution temperature (LCST) was investigated by differential scanning calorimetry (DSC). The optical absorbance and the response to illumination were determined as a function of GO concentration for thin hydrogel films. A proof of principle for the stimulation with light was performed.
An enzyme-based multi-parameter biosensor is developed for monitoring the concentration of formate, d-lactate, and l-lactate in biological samples. The sensor is based on the specific dehydrogenation by an oxidized β-nicotinamide adenine dinucleotide (NAD+)-dependent dehydrogenase (formate dehydrogenase, d-lactic dehydrogenase, and l-lactic dehydrogenase, respectively) in combination with a diaphorase from Clostridium kluyveri (EC 1.8.1.4). The enzymes are immobilized on a platinum working electrode by cross-linking with glutaraldehyde (GA). The principle of the determination scheme in case of l-lactate is as follows: l-lactic dehydrogenase (l-LDH) converts l-lactate into pyruvate by reaction with NAD+. In the presence of hexacyanoferrate(III), the resulting reduced β-nicotinamide adenine dinucleotide (NADH) is then regenerated enzymatically by diaphorase. The electrochemical detection is based on the current generated by oxidation of hexacyanoferrate(II) at an applied potential of +0.3 V vs. an Ag/AgCl reference electrode. The biosensor will be electrochemically characterized in terms of linear working range and sensitivity. Additionally, the successful practical application of the sensor is demonstrated in an extract from maize silage.