Article
Refine
Year of publication
- 2024 (2)
- 2023 (2)
- 2022 (5)
- 2021 (5)
- 2020 (6)
- 2019 (7)
- 2018 (10)
- 2017 (5)
- 2016 (12)
- 2015 (7)
- 2014 (10)
- 2013 (9)
- 2012 (9)
- 2011 (20)
- 2010 (17)
- 2009 (16)
- 2008 (19)
- 2007 (21)
- 2006 (16)
- 2005 (13)
- 2004 (17)
- 2003 (6)
- 2002 (12)
- 2001 (10)
- 2000 (14)
- 1999 (17)
- 1998 (11)
- 1997 (11)
- 1996 (9)
- 1995 (11)
- 1994 (14)
- 1993 (9)
- 1992 (7)
- 1991 (3)
- 1990 (5)
- 1989 (5)
- 1988 (5)
- 1987 (2)
- 1986 (1)
- 1985 (6)
- 1984 (1)
- 1982 (1)
- 1981 (1)
- 1980 (4)
- 1979 (2)
- 1978 (3)
- 1976 (1)
- 1975 (1)
- 1974 (1)
Document Type
- Article (401) (remove)
Language
- English (401) (remove)
Keywords
- Hot S-parameter (2)
- MINLP (2)
- 3-D printing (1)
- Automated driving (1)
- Automotive application (1)
- Benchmark (1)
- Bloom’s Taxonomy (1)
- Booster Stations (1)
- Buffering Capacity (1)
- CAV (1)
- Chance Constraint (1)
- Circuit simulation (1)
- Competence Developing Games (1)
- Engineering Application (1)
- Experimental validation (1)
- Furnace (1)
- Fusion (1)
- Game-based learning (1)
- IP-based networks (1)
- IT security education (1)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (401) (remove)
This paper introduces an inexpensive Wiegand-sensor-based rotary encoder that avoids rotating magnets and is suitable for electrical-drive applications. So far, Wiegand-sensor-based encoders usually include a magnetic pole wheel with rotating permanent magnets. These encoders combine the disadvantages of an increased magnet demand and a limited maximal speed due to the centripetal force acting on the rotating magnets. The proposed approach reduces the total demand of permanent magnets drastically. Moreover, the rotating part is manufacturable from a single piece of steel, which makes it very robust and cheap. This work presents the theoretical operating principle of the proposed approach and validates its benefits on a hardware prototype. The presented proof-of-concept prototype achieves a mechanical resolution of 4.5 ° by using only 4 permanent magnets, 2Wiegand sensors and a rotating steel gear wheel with 20 teeth.
31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and Burn:x-wiley:07403194:media:MRM24175:tex2gif-stack-1 measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer.
Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome.
ε-Fe3N has been investigated by time-of-flight neutron diffraction (temperature range 4.2–618 K) and SQUID magnetometry (2–700 K, B≤5 T). A ferromagnetic spin structure is observed with magnetic moments oriented perpendicular to the c-axis of the hexagonal nuclear structure. The magnetic saturation moment of iron is 2.2 μB at 4.2 K from neutron diffraction and 2.0 μB from magnetic measurements and decreases in a Brillouin-like manner on heating to TC=575 K. Above 450 K an increasing but reversible disorder of the nitrogen partial structure is observed.