Article
Refine
Year of publication
- 2024 (2)
- 2023 (3)
- 2022 (5)
- 2021 (6)
- 2020 (6)
- 2019 (7)
- 2018 (10)
- 2017 (5)
- 2016 (12)
- 2015 (7)
- 2014 (10)
- 2013 (10)
- 2012 (11)
- 2011 (22)
- 2010 (19)
- 2009 (18)
- 2008 (20)
- 2007 (21)
- 2006 (16)
- 2005 (13)
- 2004 (17)
- 2003 (6)
- 2002 (12)
- 2001 (10)
- 2000 (14)
- 1999 (17)
- 1998 (11)
- 1997 (11)
- 1996 (9)
- 1995 (11)
- 1994 (14)
- 1993 (9)
- 1992 (7)
- 1991 (3)
- 1990 (5)
- 1989 (5)
- 1988 (5)
- 1987 (2)
- 1986 (1)
- 1985 (6)
- 1984 (1)
- 1982 (1)
- 1981 (1)
- 1980 (4)
- 1979 (2)
- 1978 (3)
- 1976 (1)
- 1975 (1)
- 1974 (1)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (413) (remove)
Language
- English (413) (remove)
Document Type
- Article (413) (remove)
Keywords
- Hot S-parameter (2)
- MINLP (2)
- 197m/gHg (1)
- 3-D printing (1)
- Automated driving (1)
- Automotive application (1)
- Benchmark (1)
- Bloom’s Taxonomy (1)
- Booster Stations (1)
- Buffering Capacity (1)
Calibration of a Network Analyzer Without a Thru Connection for Nonlinear and Multiport Measurements
(2008)
Calibration procedures with series impedances and unknown lines simplify on-wafer measurements
(1999)
This study demonstrates the feasibility of applying free-breathing, cardiac-gated, susceptibility-weighted fast spin-echo imaging together with black blood preparation and navigator-gated respiratory motion compensation for anatomically accurate T₂ mapping of the heart. First, T₂ maps are presented for oil phantoms without and with respiratory motion emulation (T₂ = (22.1 ± 1.7) ms at 1.5 T and T₂ = (22.65 ± 0.89) ms at 3.0 T). T₂ relaxometry of a ferrofluid revealed relaxivities of R2 = (477.9 ± 17) mM⁻¹s⁻¹ and R2 = (449.6 ± 13) mM⁻¹s⁻¹ for UFLARE and multiecho gradient-echo imaging at 1.5 T. For inferoseptal myocardial regions mean T₂ values of 29.9 ± 6.6 ms (1.5 T) and 22.3 ± 4.8 ms (3.0 T) were estimated. For posterior myocardial areas close to the vena cava T₂-values of 24.0 ± 6.4 ms (1.5 T) and 15.4 ± 1.8 ms (3.0 T) were observed. The merits and limitations of the proposed approach are discussed and its implications for cardiac and vascular T₂-mapping are considered.
This paper introduces a new maritime search and rescue system based on S-band illumination harmonic radar (HR). Passive and active tags have been developed and tested while attached to life jackets and a small boat. In this demonstration test carried out on the Baltic Sea, the system was able to detect and range the active tags up to a distance of 5800 m using an illumination signal transmit-power of 100 W. Special attention is given to the development, performance, and conceptual differences between passive and active tags used in the system. Guidelines for achieving a high HR dynamic range, including a system components description, are given and a comparison with other HR systems is performed. System integration with a commercial maritime X-band navigation radar is shown to demonstrate a solution for rapid search and rescue response and quick localization.