Refine
Year of publication
- 2012 (332) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (72)
- Fachbereich Wirtschaftswissenschaften (42)
- Fachbereich Chemie und Biotechnologie (40)
- Fachbereich Elektrotechnik und Informationstechnik (40)
- INB - Institut für Nano- und Biotechnologien (32)
- IfB - Institut für Bioengineering (31)
- Fachbereich Bauingenieurwesen (30)
- Fachbereich Maschinenbau und Mechatronik (29)
- Fachbereich Energietechnik (20)
- Solar-Institut Jülich (15)
Document Type
- Article (130)
- Conference Proceeding (89)
- Part of a Book (36)
- Book (26)
- Conference: Meeting Abstract (17)
- Patent (12)
- Part of a Periodical (9)
- Doctoral Thesis (6)
- Report (4)
- Habilitation (1)
Keywords
- Elektromobilität (7)
- Elektrofahrzeug (5)
- Energieversorgungsnetz (5)
- Kraftfahrzeugelektronik (5)
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (2)
- Elektromobilität; Elektrofahrzeug; Energieversorungsnetz; Kraftfahrzeugtechnik (2)
- (Bio)degradation (1)
- 3. EU Legislativpaket (1)
- 802.15.4 (1)
Real-time and reliable monitoring of the biogas process is crucial for a stable and efficient operation of biogas production in order to avoid digester breakdowns. The concentration of dissolved hydrogen (H₂) represents one of the key parameters for biogas process control. In this work, a one-chip integrated combined amperometric/field-effect sensor for monitoring the dissolved H₂ concentration has been developed for biogas applications. The combination of two different transducer principles might allow a more accurate and reliable measurement of dissolved H₂ as an early warning indicator of digester failures. The feasibility of the approach has been demonstrated by simultaneous amperometric/field-effect measurements of dissolved H₂ concentrations in electrolyte solutions. Both, the amperometric and the field-effect transducer show a linear response behaviour in the H₂ concentration range from 0.1 to 3% (v/v) with a slope of 198.4 ± 13.7 nA/% (v/v) and 14.9 ± 0.5 mV/% (v/v), respectively.
In der Molkeverarbeitung dominieren Membranfiltrationsverfahren die Prozessführung. Hierbei werden üblicherweise Aufkonzentrierungen der Proteine und deren Trennung von dem Milchzucker Lactose durchgeführt. Der Prozess der adsorptiven Aufreinigung soll als kostengünstige Alternative zu den bisher gebräuchlichen Verfahren dienen. Weiterhin eröffnet sich durch das Verfahren die Möglichkeit, einzelne Proteinfraktionen während der Verarbeitung anzureichern. Als Proteinquellen wurden für die Untersuchungen Modellproteine, Lösungen aus Molkenproteinisolat, Dünnmolke und Molkekonzentrat verwendet. Die Eignung zur Proteinbindung wurden an Tonmaterialien, Silicaten und y-Aluminiumoxiden in Pulverform, in Form von Granulaten sowie Extrudaten als auch sphärischen Partikeln überprüft. Adsorbentien aus Bentonit/Silica und c-Aluminiumoxid können sowohl a-Lactalbumin (aLA) als auch b-Lactoglobulin (bLG) binden, wohingegen Materialien aus Siliciumoxid lediglich ein starkes Adsorptionsverhalten gegenüber bLG zeigen. Mischmaterialien aus Siliciumoxid und a-Aluminiumoxid zeigen dasselbe Verhalten wie Materialien aus Siliciumoxid, weisen jedoch eine geringere Kapazität auf. Die Materialen wurden hinsichtlich ihres Einsatzes in chromatographischen Verfahren und Batch-Prozessen untersucht und ein Prozessentwurf für einen zweistufigen Batch-Prozess im Rührkessel erarbeitet.
Visual Virology
(2012)
Security Awareness ist derzeit ein viel diskutiertes Thema. Es reicht nicht, einfach nur ein paar technische Systeme (z.B. Firewalls) zu installieren, um ein angemessenes Schutzniveau zu erzielen. Neben einer guten Organisation von IT Security ist es auch notwendig, den Mitarbeiter einzubinden. Der vielzitierte "Faktor Mensch" ist derjenige, der die Technik korrekt anwenden muss und der durch falsches Verhalten technische und organisatorische Schutzmaßnahmen aushebeln kann. Deshalb reicht es nicht aus, wenn sich der Mitarbeiter der Gefahren bewusst ("aware") ist, er muss auch dementsprechend "sicher" handeln.
Cardiac MR (CMR) is of proven clinical value but also an area of vigorous ongoing research since image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Recent developments of CMR at 7.0 T have been driven by pioneering explorations into novel multichannel transmit and receive coil array technology to tackle the challenges B1+-field inhomogeneities, to offset specific-absorption rate (SAR) constraints and to reduce banding artifacts in SSFP imaging. For this study, recognition of the benefits and performance of local surface Tx/Rx-array structures recently established at 7.0 T inspired migration to 3.0 T, where RF inhomogeneities and SAR limitations encountered in routine clinical CMR, though somewhat reduced versus the 7.0 T situation, remain significant. For all these reasons, this study was designed to build and examine the feasibility of a local four channel Tx/Rx cardiac coil array for anatomical and functional cardiac imaging at 3.0 T. For comparison, a homebuilt 4 channel Rx cardiac coil array exhibiting the same geometry as the Tx/Rx coil and a Rx surface coil array were used.
A magnetic resonance tomography (MRT) apparatus (1) for the examination of a body (14) comprises parameter acquisition devices (13) for the acquisition of cardiovascular parameters of the body (14) and a control device (15) in communication with the parameter acquisition devices (13) for synchronizing the imaging, wherein the control device (15) is adapted to analyse the data of at least two parameter acquisition devices (13) and to output a control signal based on the analysis.
Upper and lower bound theorems of limit analyses have been presented in part I of the paper. Part II starts with the finite element discretization of these theorems and demonstrates how both can be combined in a primal–dual optimization problem. This recently proposed numerical method is used to guide the development of a new class of closed-form limit loads for circumferential defects, which show that only large defects contribute to plastic collapse with a rapid loss of strength with increasing crack sizes. The formulae are compared with primal–dual FEM limit analyses and with burst tests. Even closer predictions are obtained with iterative limit load solutions for the von Mises yield function and for the Tresca yield function. Pressure loading of the faces of interior cracks in thick pipes reduces the collapse load of circumferential defects more than for axial flaws. Axial defects have been treated in part I of the paper.
Stahlbau
(2012)
Die Hochgradientenmagnetseparation (HGMS) ist eine Methode zur Aufreinigung von biopharmazeutischen Produkten. Mit dieser Methode lässt sich in nur einem Schritt eine Fest/Fest/Flüssig-Trennung erzielen, was zu einer erheblichen Zeit- und Kostenersparnis im Downstreaming führt. Dennoch steht ihr industrieller Einsatz noch aus, was u. a. am Mangel an Analysenmethoden liegt, um die HGMS quantifizierbar zu machen. Gerade in der Pharmaproduktion werden Prozesse gebraucht, die gemäß den einschlägigen Vorschriften (cGMP) validiert und deren verfahrenstechnische Anlagenteile qualifiziert werden können. Die Schwierigkeit ist die Messung der magnetischen Mikrosorbentien in der Suspension, in der auch Zellen oder Zelltrümmer vorliegen. Im Rahmen eines Forschungsprojektes im „Zentralen Innovationsprogramm Mittelstand“ des BMWi wurden verschiedene Analysenmethoden untersucht. Die Durchflusszytometrie ermöglicht eine Charakterisierung von Partikeln und eine simultane quantitative Messung. Durch die multiparametrige Messung kann zwischen Zellen, Zelltrümmern und Magnetpartikeln unterschieden werden. Die At-line-Einbindung des Durchflusszytometers ist durch den Einsatz einer externen Pumpe möglich. Über eine automatisierte Messwertanalyse kann der HGMS-Prozess mittels der Durchflusszytometrie gesteuert werden.
Auch mit der jüngsten Finanzkrise hat die Konsumkultur nichts von ihrer Bedeutung als massenkulturelles Phänomen eingebüßt. Im Gegenteil: Das aktuelle Krisenbewusstsein sucht Halt im Konsum, der seinen Verfechtern noch immer als Modell demokratischer Teilhabe an gesellschaftlicher Produktion gilt. Zugleich ist die Konsumkritik der 1960er Jahre in Richtung eines intelligenten und nachhaltigen Konsums weitergeführt worden, und selbstbewusste Konsumenten treten nun als emanzipierte »Prosumer« und Mitakteure des Marktes auf. Das Buch entwickelt aus Sicht von Design, Kunst, Soziologie, Marketing und Medien neue Perspektiven auf das Phänomen Konsum.