Article
Refine
Year of publication
Institute
- Fachbereich Elektrotechnik und Informationstechnik (413) (remove)
Language
- English (413) (remove)
Document Type
- Article (413) (remove)
Keywords
- Hot S-parameter (2)
- MINLP (2)
- 197m/gHg (1)
- 3-D printing (1)
- Automated driving (1)
- Automotive application (1)
- Benchmark (1)
- Bloom’s Taxonomy (1)
- Booster Stations (1)
- Buffering Capacity (1)
- CAV (1)
- Cardiovascular Magnetic Resonance (1)
- Chance Constraint (1)
- Circuit simulation (1)
- Competence Developing Games (1)
- EGG (1)
- Engineering Application (1)
- Experimental validation (1)
- Furnace (1)
- Fusion (1)
- Game-based learning (1)
- Gold nanoparticle (AuNP) (1)
- High field MRI (1)
- IP-based networks (1)
- IT security education (1)
- Image Quality Assessment (1)
- Image Quality Score (1)
- Interval Time Series (1)
- Keyword analysis (1)
- Larynx position (1)
- Lidar (1)
- MILP (1)
- MR safety (1)
- MRI (1)
- Magneto alert sensor (1)
- Meitner-Auger-electron (MAE) (1)
- Mode converter (1)
- Modeling (1)
- NGN (1)
- Plasma (1)
- Plasma diagnostics (1)
- Powertrain (1)
- Process virtualization (1)
- Product bundling (1)
- Pump System (1)
- Pumping systems (1)
- Radar (1)
- Rotary encoder (1)
- Self-driving (1)
- Services (1)
- Sound Pressure Level (1)
- Stochastic Programming (1)
- Targeted radionuclide therapy (TRT) (1)
- Technical Operations Research (1)
- Telecommunication (1)
- Tomography (1)
- Transfer impedance (1)
- Transformation (1)
- Uktrahigh field MRI (1)
- Uncertainty (1)
- VOP compression (1)
- Voice assessment (1)
- Water Distribution (1)
- Water Supply Networks (1)
- Wiegand sensor (1)
- automated vehicles (1)
- availability (1)
- batteries and fuel cells (1)
- body imaging at 7 T MRI (1)
- body imaging at UHF MRI (1)
- connected automated vehicles (1)
- design of technical systems (1)
- electrospinning (1)
- energy efficiency (1)
- energy transfer (1)
- experimental evaluation (1)
- fibers (1)
- genetic algorithm (1)
- global optimization (1)
- harmonic radar (1)
- harmonic radar tags (1)
- heating system (1)
- ignition (1)
- integrated transmit coil arrays (1)
- irradiation (1)
- legal obligations (1)
- mathematical optimization (1)
- microplasma (1)
- microwave (MW) plasma (1)
- microwave measurements (1)
- mixed-integer linear programming (1)
- next generation network (1)
- nonlinear VNA measurements (1)
- optimization (1)
- plasma jet (1)
- porous materials (1)
- product bundling (1)
- product liability (1)
- programming (1)
- remote sensing (1)
- resilience (1)
- slum classification (1)
- stochastic optimization (1)
- sustainability (1)
- system optimization (1)
- system synthesis (1)
- technical operations research (1)
- telecommunication (1)
- thermal dose (1)
- tissue temperature (1)
- transmit antenna arrays (1)
- water supply design (1)
An Analysis of Retransmission Strategies for Reliable Multicast Protocols / Schuba, M. ; Reichl, P.
(1998)
Performance Investigations of the IP Multicast Architecture / Hermanns, Oliver ; Schuba, Marko
(1995)
A novel method to determine the extruded length of a metallic wire for a directed energy deposition (DED) process using a microwave (MW) plasma jet with a straight-through wire feed is presented. The method is based on the relative comparison of the measured frequency response obtained by the large-signal scattering parameter (Hot-S) technique. In the practical working range, repeatability of less than 6% for a nonactive plasma and 9% for the active plasma state is found. Measurements are conducted with a focus on a simple solution to decrease the processing time and reduce the integration time of the process into the existing hardware. It is shown that monitoring a single frequency for magnitude and phase changes is sufficient to achieve good accuracy. A combination of different measurement values to determine the length is possible. The applicability to different diameter of the same material is shown as well as a contact detection of the wire and metallic substrate.
This paper describes the development of a capacitively coupled high-pressure lamp with input power between 20 and 43 W at 2.45 GHz, using a coaxial line network. Compared with other electrodeless lamp systems, no cavity has to be used and a reduction in the input power is achieved. Therefore, this lamp is an alternative to the halogen incandescent lamp for domestic lighting. To serve the demands of domestic lighting, the filling of the lamp is optimized over all other resulting requirements, such as high efficacy at low induced powers and fast startups. A workflow to develop RF-driven plasma applications is presented, which makes use of the hot S-parameter technique. Descriptions of the fitting process inside a circuit and FEM simulator are given. Results of the combined ignition and operation network from simulations and measurements are compared. An initial prototype is built and measurements of the lamp's lighting properties are presented along with an investigation of the efficacy optimizations using large signal amplitude modulation. With this lamp, an efficacy of 135 lmW -1 is achieved.
Thermal and Optical Study on the Frequency Dependence of an Atmospheric Microwave Argon Plasma Jet
(2019)
Quantitative Farbmessung in laryngoskopischen Bildern. Palm, C; Scholl, I; Lehmann, TM; Spitzer, K.
(1998)
Compared to peripheral pain, trigeminal pain elicits higher levels of fear, which is assumed to enhance the interruptive effects of pain on concomitant cognitive processes. In this fMRI study we examined the behavioral and neural effects of trigeminal (forehead) and peripheral (hand) pain on visual processing and memory encoding. Cerebral activity was measured in 23 healthy subjects performing a visual categorization task that was immediately followed by a surprise recognition task. During the categorization task subjects received concomitant noxious electrical stimulation on the forehead or hand. Our data show that fear ratings were significantly higher for trigeminal pain. Categorization and recognition performance did not differ between pictures that were presented with trigeminal and peripheral pain. However, object categorization in the presence of trigeminal pain was associated with stronger activity in task-relevant visual areas (lateral occipital complex, LOC), memory encoding areas (hippocampus and parahippocampus) and areas implicated in emotional processing (amygdala) compared to peripheral pain. Further, individual differences in neural activation between the trigeminal and the peripheral condition were positively related to differences in fear ratings between both conditions. Functional connectivity between amygdala and LOC was increased during trigeminal compared to peripheral painful stimulation. Fear-driven compensatory resource activation seems to be enhanced for trigeminal stimuli, presumably due to their exceptional biological relevance.
Short term effects of magnetic resonance imaging on excitability of the motor cortex at 1.5T and 7T
(2010)
Rationale and Objectives
The increasing spread of high-field and ultra-high-field magnetic resonance imaging (MRI) scanners has encouraged new discussion of the safety aspects of MRI. Few studies have been published on possible cognitive effects of MRI examinations. The aim of this study was to examine whether changes are measurable after MRI examinations at 1.5 and 7 T by means of transcranial magnetic stimulation (TMS).
Materials and Methods
TMS was performed in 12 healthy, right-handed male volunteers. First the individual motor threshold was specified, and then the cortical silent period (SP) was measured. Subsequently, the volunteers were exposed to the 1.5-T MRI scanner for 63 minutes using standard sequences. The MRI examination was immediately followed by another TMS session. Fifteen minutes later, TMS was repeated. Four weeks later, the complete setting was repeated using a 7-T scanner. Control conditions included lying in the 1.5-T scanner for 63 minutes without scanning and lying in a separate room for 63 minutes. TMS was performed in the same way in each case. For statistical analysis, Wilcoxon's rank test was performed.
Results
Immediately after MRI exposure, the SP was highly significantly prolonged in all 12 subjects at 1.5 and 7 T. The motor threshold was significantly increased. Fifteen minutes after the examination, the measured value tended toward normal again. Control conditions revealed no significant differences.
Conclusion
MRI examinations lead to a transient and highly significant alteration in cortical excitability. This effect does not seem to depend on the strength of the static magnetic field.