Refine
Year of publication
- 2001 (221) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (54)
- INB - Institut für Nano- und Biotechnologien (39)
- Fachbereich Elektrotechnik und Informationstechnik (33)
- Fachbereich Wirtschaftswissenschaften (28)
- Fachbereich Energietechnik (27)
- Fachbereich Luft- und Raumfahrttechnik (23)
- Fachbereich Chemie und Biotechnologie (18)
- Fachbereich Maschinenbau und Mechatronik (18)
- Fachbereich Bauingenieurwesen (9)
- Fachbereich Architektur (5)
Language
- German (114)
- English (106)
- Multiple languages (1)
Document Type
- Article (157)
- Book (31)
- Conference Proceeding (23)
- Part of a Book (4)
- Contribution to a Periodical (2)
- Report (2)
- Doctoral Thesis (1)
- Patent (1)
Keywords
- Blitzschutz (3)
- Einspielen <Werkstoff> (3)
- Content Management (2)
- Lightning protection (2)
- Strömungsmaschine (2)
- Turbine (2)
- CMS (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
Lightning protection design of a renewable energy hybrid-system without power mains connection
(2001)
Rapid Prototyping and PIV
(2001)
Laserwelding with fillerwire
(2001)
Im Rahmen eines modernen Blitzschutzsystems für Stahlbeton-Bauten bietet es sich an, die Betonbewehrung zu benutzen: - Sie kann die Funktionen der Ableitungseinrichtungen und des Blitzschutz- Potentialausgleichs bei einem klassischen Gebäude-Blitzschutz übernehmen [1]; - Sie kann, ggf. bei entsprechender Ergänzung, als ein geschlossener Käfig ausgebildet werden und damit eine deutliche Reduzierung der Belastung elektrischer / elektronischer Systeme durch blitzinduzierte elektromagnetische Felder erbringen (LEMP-Schutz [2]). Die Nutzung der Bewehrung ist dabei grundsätzlich gleichermaßen bei Neubauten wie auch bei Ertüchtigungen möglich und sinnvoll. So stellt die Nutzung der Bewehrung beispielsweise im Bereich von Großkraftwerken eine wesentliche Ertüchtigungsmaßnahme für den Blitzschutz elektrischer und elektronischer Einrichtungen dar: - Einerseits wird der Blitzschutz-Potentialausgleich durch den Anschluss metallener Einrichtungen wie Elektronik-Schränke, Kabeltrag-Konstruktionen, Rohrleitungen, etc. an die Bewehrung deutlich verbessert. - Andererseits kann bei größeren Gebäuden die elektromagnetische Schirmwirkung durch die elektrische Überbrückung von vorhandenen Dehnfugen bei Stahlbetonbauten optimiert werden. Diese Dehnfugen sind teilweise nur unzureichend überbrückt, so dass bei Blitzeinschlag in das betreffende oder ein benachbartes Gebäude an Kabelstrecken, die über die Dehnfuge hinwegführen, rel. hohe Spannungen induziert werden können [2, 3]. Die sich um das gesamte Gebäude herumziehende oder zwischen zwei Gebäuden befindliche Dehnfuge muss deshalb im Abstand von maximal einigen Metern überbrückt werden. Im Falle von Blitzschutz-Ertüchtigungen in vorhandenen Gebäuden wird bisher an jeder geplanten Anschlussstelle die Bewehrung großflächig (∅ wenige 10 cm) freigelegt, dort ein elektrischer Anschluss zu dem Bewehrungsstab hergestellt, z.B. mittels eines Erdungsfestpunkts, und dann die Betonoberfläche wieder geschlossen. Je nach prognostizierter Strombelastung wird teilweise versucht, den über den Anschluss fließenden Strom bereits auf mehrere Bewehrungsstäbe zu verteilen. Dazu sind entweder die kreuzenden Stäbe zu verschweißen oder es sind direkt Anschlüsse an zwei Bewehrungsstäbe herzustellen. All dieses bedeutet einen hohen Aufwand bei der Freilegung der Bewehrung und auch wieder bei der Schließung der entstandenen Betonlöcher. Es soll deshalb hier untersucht werden, ob es beispielsweise zum Zwecke des Blitzschutz-Potentialausgleichs und auch zur Überbrückung von Dehnfugen ausreichend ist, den Anschluss an die Bewehrung nach einfachen Verfahren nur jeweils an einen Bewehrungsstab herzustellen. Damit würde der finanzielle und administrative Aufwand an Betonarbeiten deutlich reduziert. Die hier dargestellten Verfahren sind dabei insbesondere für den Einsatz bei Blitzschutz-Ertüchtigungen in bestehenden Gebäuden vorgesehen. Abschließend sollen deshalb die Möglichkeiten zur Prüfung korrekter Anschlüsse, die Grenzen der Verfahren sowie auch die Grenzen der Anwendbarkeit bei Neuanlagen diskutiert werden.
Blitzschutzkonzept für eine netz-autarke Hybridanlage am Beispiel der Anlage VATALI auf Kreta
(2001)
Netz-autarke Anlagen bestehen üblicherweise aus einer oder mehreren Photovoltaik- (PV-) Anlagen, ggf. auch Solarthermie- (ST-) Anlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet) und werden vor allem in Gegenden mit sehr schlechter öffentlicher Energieversorgung eingesetzt, d.h. insbesondere in rel. dünn bewohnten Gebieten und in Entwicklungsländern. Der Blitzschutz von netz-autarken Hybridanlagen ist ein bislang noch vergleichsweise unzureichend bearbeitetes Fachgebiet. Für große Windenergie-Anlagen (WEA) wurde in den letzten Jahren eine Zahl von FuE-Projekten durchgeführt, zum Großteil finanziert durch die öffentliche Hand, zum kleineren Teil auch durch die Industrie, d.h. die WEAHersteller. Dabei wurden bestehende Defizite im Design der WEA festgestellt und Maßnahmen vorgeschlagen, die vor den mechanischen Zerstörungen insbesondere des Rotors und vor den Störungen und Zerstörungen an den elektrischen / elektronischen Systemen der WEA weitgehend Schutz bieten [1, 2, 3]. Der Stand-der- Normung ist im Entwurf DIN VDE 0127 Teil 24 „Blitzschutz für Windenergieanlagen“ (dt. Übersetzung des internationalen Drafts IEC 61400-24 „Wind turbine generator systems; Part 24: Lightning Protection“) dokumentiert [4]. Die Maßnahmen sind allerdings insbesondere für größere WEA vorgesehen; im Falle kleinerer WEA lassen sie sich nur bedingt umsetzen. Trotzdem sind auch kleinere WEA rel. stark blitzeinschlaggefährdet, wenn sie auf einer Bergkuppe o.ä. platziert werden. Für solche kleinere WEA, wie sie bei Hybridanlagen üblicherweise Verwendung finden, müssen die Blitzschutzmaßnahmen aus der DIN VDE 0127 Teil 24 angepasst werden. Für PV- und ST-Anlagen ist eine entsprechende Blitzschutz-Norm noch nicht in Sicht. Hier ist vor allem der Schutz gegen direkte Blitzeinschläge in die Anlage bzw. die Gebäude noch nicht ausreichend beachtet. Blitzfangeinrichtungen sind oft nicht vorgesehen. In aller Regel hat man dabei bisher eine Ausführungsform des Blitzschutzes realisiert, die primär einen Ferneinschlag berücksichtigt und die dabei entstehenden induzierten, rel. energieschwachen Überspannungen durch schwächere Schutzelemente wie Rückstromdioden, Bypassdioden und zum Teil thermisch überwachte Varistoren begrenzt [5, 6, 7]. Diese Schutzelemente können allerdings bei Naheinschlägen bzw. Direkteinschlägen überlastet und damit zerstört werden. Darüber hinaus können Nahoder Direkteinschläge auch zur Schwächung der elektrischen Festigkeit der PVModulisolierung führen. Die Folge davon sind lokale extreme Wärmeentwicklungen, die sogar ein Schmelzen von Glas (sekundärer Langzeiteffekt) hervorrufen könnten. Bei einem Blitzeinschlag in die netz-autarke Hybridanlage VATALI auf Kreta im Jahre 2000 wurden sowohl einige mechanische wie auch elektrische Komponenten der Anlage zerstört bzw. zum Teil schwer beschädigt. Die Anlage VATALI besaß zum Zeitpunkt des Blitzeinschlags keinen wirksamen Blitzschutz. Der Gesamtschaden der Hardware belief sich auf ca. 60.000,- EURO. Die exponierte Stellung der Anlage auf einer Bergspitze stellte und stellt nach wie vor ein enormes Blitzeinschlag-Risiko dar, so dass auch zukünftig mit Blitzeinwirkungen gerechnet werden muss. Die Anlage wurde inspiziert, blitzschutz-technische Erfordernisse definiert und daraus Ertüchtigungsmaßnahmen abgeleitet, die mit überschaubarem Aufwand realisierbar sind.
Lightning protection design of a renewable energy hybrid-system without power mains connection
(2001)
In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.
Der CMS-Guide
(2001)
Lohr, J. ; Deppe, A: Der CMS-Guide. Content Management-Systeme: Erfolgsfaktoren, Geschäftsmodelle, Produktübersicht. Stand: 3.9.2001 [Manuskript]. Braunschweig: Vieweg 2001. XVII, 253 S. ISBN 3-528-05768-8 [Aufl. vergriffen] Nach einer Einführung in die Grundlagen des Content Managements, in der die Begriffe Daten, Content Prozess und Content Life Cycle erläutert werden, erfolgt eine Klassifizierung von Content-Management-Systemen in die Bereiche Cross Media Publishing, Infobroker (Syndica-tor), Dokumentenmanagement, Informationspool, Unternehmensinformation, Wissensmanagement, Training, Portale, Customer Interaction & Care, Customer Relationship Management, Kommerzielle Community, Application Service Provider, E-Commerce und Marktplätze. Anhand einer technischen und inhaltlichen Zusammenfassung der Einsatzbereiche ergeben sich die Leistungsmerkmale: Visualizing, Retrieval, Organizing, Collaboration, Modularisierung, Skalierbarkeit und Authoring. Produkte werden den Einsatzbereichen zugeordnet und ausführlich beschrieben. Dabei fällt auf, dass bei den "Top-20-Produkten" die Bereiche Cross Media Publishing, Unternehmensinformation und Informationspool dominieren. Geringe Unterstützung erfahren zurzeit die Bereiche Wissensmanagement, Customer Interaction & Care sowie Training. Ein kritischer Erfolgsfaktor für die Einführung und den Betrieb eines Content-Management-Systems ist die Unterstützung des gewählten Geschäftsmodells. Die Einführung kann durch technische und organisatorische Auswahlverfahren unterstützt werden. Ein Schichtenmodell zeigt die Einbindung oder Optimierung eines Content-Management-Systems in ein Unternehmen. Einerseits können organisatorische, innerbetriebliche und marktorientierte Anforderungsprofile abgeleitet werden, andererseits ergeben sich aus der innerbetrieblichen IT-Struktur Determinanten für die Leistungs-merkmale und den Funktionsumfang des auszuwählenden Content-Management-Systems. Als ein wesentlicher kritischer Erfolgsfaktor stellte sich heraus, dass das Content-Management-System in der Lage sein sollte, dynamische Geschäftsmodelle abzubilden. Dieses Kriterium wird zusätzlich durch die diversen Checklisten, deren Aufbau auf dem Schichtenmodell basiert, herausgearbeitet.
In: Unterrichtsblätter / Deutsche Telekom AG. 54. 2001. 7. S. 410-420 (11 S. ) Angesichts der zunehmenden Globalisierung von Informationen und Informationsdiensten können Inhalte (Contents) für mehrere unterschiedliche Dienste genutzt und auf verschiedenen Endgeräten ausgegeben werden. Hier setzt ein Content-Management-System (CMS) an, welches sowohl für die Kunden als auch für die Anbieter der unterschiedlich distribuierten Dienste Synergien und somit Einsparpotenziale bietet. Darüber hinaus werden für die Anbieter dieser Dienste durch die allgemeine Definition von Leistungstools und die Definition von Wertschöpfungsketten künftige Produktentwicklungen vereinheitlicht und optimiert werden. Mit der Entwicklung und Vertriebsfreigabe immer weiterer Informationsdienste, die von verschiedenen Dienste-Providern betrieben werden, ist der Bedarf an einer Koordinierung der Entwicklungen und Investitionen im Bereich der Content-Akquisition und des Content-Management (CM) bedeutend angestiegen. Neben Akquisition, lizenzrechtlichen Fragen und Verwaltung des im Rahmen von Diensten angebotenen Content rücken vor allem auch Fragen der Gestaltung von Content-Management-Plattformen (CMP) immer stärker in den Blickpunkt. Der Beitrag stellt die globalen Ergebnisse dar, die in einem Forschungs- und Entwicklungsauftrag des Zentralbereichs Innovationsmanagement der Deutschen Telekom zu diesem Thema ermittelt wurden. Es werden die Kernmodule für eine Content- Management-Plattform beschrieben, die die Anforderungen an die Bereitstellung vielfältiger Content-Angebote erfüllt. Die folgenden Themen werden behandelt: + Begriffsbestimmung, + Content- und Dienste-Portfolio, + Standard Content-Prozess, + synergetische Content-Plattform (sCP), + Modelle der sCP, + Aspekte beim Betrieb und + Nutzen eines Content-Management.
Das Verbraucherkreditgesetz
(2001)
Virtual Reality und Simulation als integrierte Werkzeuge für die Entwicklung mechatronischer Systeme
(2001)
Knowledge Management
(2001)
Organisationslehre
(2001)
Thin film chemical sensors based on chalcogenide glasses for „electronic tongue“ applications
(2001)
Characterising an insect antenna as a receptor for a biosensor by means of impedance spectroscopy
(2001)
The motion aftereffect is a perceptual phenomenon which has been extensively investigated both psychologically and physiologically. Neuroimaging techniques have recently demonstrated that area V5/MT is activated during the perception of this illusion. The aim of this study was to test the hypothesis if a more broadly distributed network of brain regions subserves the motion aftereffect. To identify the neuronal structures involved in the perception of the motion aftereffect, regional cerebral blood flow (rCBF) measurements with positron emission tomography were performed in six normal volunteers. Data were analysed using SPM96. The motion-sensitive visual areas including area V5/MT were activated in both hemispheres. Additionally, the lateral parietal cortex bilaterally, the right dorsolateral prefrontal cortex, the anterior cingulate cortex and the left cerebellum showed significant increases in rCBF values during the experience of the waterfall illusion. In a further reference condition with identical attentional demand but no perception of a motion aftereffect elevated rCBF were found in these regions as well. In conclusion, our findings support the notion that the perceptual illusion of motion arises exclusively in the motion-sensitive visual area V5/MT. In addition, a more widespread network of brain regions including the prefrontal and parietal cortex is activated during the waterfall illusion which represents a non-motion aftereffect-specific subset of brain areas but is involved in more basic attentional processing and cognition.
Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free-running ADCs at a sampling rate of 40 MHz. A four-channel acquisition board has been developed which is equipped with four 12-bit ADCs connected to one field programmable gate array (FPGA). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware trigger can be omitted. The method of free-running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. This information is crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows very high count rates to be dealt with. Since this method is to be employed in positron emission tomography (PET), the position of an event is also important. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO scintillators coupled to the PS-PMT are presented here