Refine
Year of publication
- 2006 (330) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (75)
- Fachbereich Bauingenieurwesen (51)
- Fachbereich Wirtschaftswissenschaften (45)
- Fachbereich Luft- und Raumfahrttechnik (32)
- Fachbereich Energietechnik (29)
- Fachbereich Maschinenbau und Mechatronik (29)
- Fachbereich Elektrotechnik und Informationstechnik (27)
- IfB - Institut für Bioengineering (24)
- INB - Institut für Nano- und Biotechnologien (22)
- Fachbereich Chemie und Biotechnologie (17)
Language
- German (166)
- English (160)
- Russian (2)
- Portuguese (1)
- Spanish (1)
Document Type
- Article (180)
- Conference Proceeding (94)
- Book (29)
- Patent (6)
- Part of a Book (5)
- Diploma Thesis (3)
- Lecture (3)
- Other (3)
- Course Material (2)
- Report (2)
Keywords
- Biosensor (23)
- CAD (3)
- Technische Mechanik (3)
- Bauingenieurwesen (2)
- Bauplanung (2)
- Führung (2)
- Leadership (2)
- Motivation (2)
- Rapid Prototyping (2)
- Rapid prototyping (2)
- Self-Leadership (2)
- biosensor (2)
- civil engineering (2)
- 3-nitrofluoranthene (1)
- 3D (1)
- ACCESS 2003 (1)
- ACCESS <Programm> (1)
- Aachen / Fachhochschule Aachen (1)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (1)
- Aachen University of Applied Sciences (1)
- Absolvententreffen (1)
- Abwasser (1)
- Access (1)
- Actor (1)
- Alfha.net (1)
- Alumni (1)
- Anlagenwirtschaft (1)
- Asteroid Deflection (1)
- AutoCAD (1)
- AutoCAD 2005 (1)
- BTEX compounds (1)
- Bauführung (1)
- Bauherrenvertretung (1)
- Bauleitung (1)
- Baurevision (1)
- Berufsperspektiven (1)
- Biosensorik (1)
- Bruchmechanik (1)
- CO (1)
- Charakter (1)
- Conducing polymer (1)
- Deutsche Bahn Netz AG (1)
- Drahtgittermodell (1)
- ECT (1)
- EPN (1)
- Elastostatics (1)
- Erik (1)
- Evaluation (1)
- Fachhochschule Aachen (1)
- Finite-Elemente-Methode (1)
- Fluorescence (1)
- Fontlab (1)
- Forum Typografie (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Gefühl (1)
- Generative Fertigungstechnik (1)
- Gesichtsausdruck (1)
- Gesichtsmodellierung (1)
- Gesichtsmuskel (1)
- Gewässerausbau (1)
- Gunn diode (1)
- Hand-on-training (1)
- Harlekin (1)
- Hauptbahnhof Aachen (1)
- Hausanschluss (1)
- Heavy metal detection (1)
- High throughput experimentation (1)
- Hochdruckleitung (1)
- Hochschuldidaktik (1)
- Hochwasserschutz (1)
- Hotplate (1)
- Hydrogen sensor (1)
- I3S 2005 (1)
- ISFET (1)
- Ingenieurbau (1)
- International Symposium on Sensor Science (1)
- Kanalbetrieb (1)
- Kanalnetz (1)
- Karosseriebau (1)
- Kinematics (1)
- Kinetics (1)
- Konstruktiver Ingenieurbau (1)
- LED chip (1)
- Leitungsbau (1)
- Leitungsbauunternehmen (1)
- Level sensor (1)
- Lightweight car body construction (1)
- MEMS ; education and training foundry (1)
- Main sensitivity (1)
- Mechanics (1)
- Mentorenprogramm (1)
- Microreactors (1)
- Mimik (1)
- Modellierung (1)
- N-A-Modelle (1)
- Nanoparticles (1)
- Nanostructuring (1)
- Niederschlag-Abfluss-Modelle (1)
- Open Type (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- PFM (1)
- PIMS (1)
- Phenylalanine determination (1)
- Pipeline Integrity Management System (1)
- Planetary Protection (1)
- Potentiometry (1)
- Pseudomonas putida (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Rapid Manufacturing (1)
- Rapid Technologie (1)
- Reaction-diffusion (1)
- Relationale Datenbank (1)
- Schrift (1)
- Schriftentwurf (1)
- Schriftkunst (1)
- Solar Sail (1)
- Solid amalgam electrodes (1)
- Spiekermann (1)
- Stahlblech-Leichtmetall Verbundguss (1)
- Stahlblech-Leichtmetall-Hybride (1)
- Statics (1)
- Statiker (1)
- Stereolithographie (1)
- Technologietransfer (1)
- Telekommunikationsmarkt (1)
- Tin oxide (1)
- Trajectory Optimization (1)
- Tunnelbau (1)
- Typographie (1)
- Umbauplanung (1)
- Verbundguss (1)
- Verkehrsbau (1)
- Virtual Technology Lab (1)
- Virtuelles Labor (1)
- Virtuelles Laboratorium (1)
- Wafer (1)
- actor (1)
- ammonia gas sensors (1)
- amperometric sensor (1)
- antimony doped tin oxide (1)
- capillary micro-droplet cell (1)
- carcinogens (1)
- catalytic decomposition (1)
- character (1)
- chemical reduction method (1)
- cross sensitivity (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- enzymatic methods (1)
- enzyme immobilisation (1)
- facial expression (1)
- facial modeling (1)
- fenitrothion (1)
- fluidic (1)
- font (1)
- fontlab (1)
- gas sensor (1)
- gas sensor array (1)
- heater metallisation (1)
- high-temperature stability (1)
- humidity (1)
- hydrogen peroxide (1)
- image sensor (1)
- imaging (1)
- impedance spectroscopy (1)
- ion-selective electrodes (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- layer expansion (1)
- lenslet array (1)
- magnetic particles (1)
- matrix method (1)
- metal oxide (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-interface measurement (1)
- nitrogen oxides (1)
- open type (1)
- organic PVC membranes (1)
- pH-based biosensing (1)
- pattern-size reduction (1)
- polymer composites (1)
- porous Pt electrode (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- quantum charging (1)
- rapid manufacturing (1)
- screen-printing (1)
- self-aligned patterning (1)
- sensing properties (1)
- sterilisation (1)
- surface modification (1)
- swift heavy ions (1)
- technology diffusion (1)
- technology transfer (1)
- thick-film technology (1)
- thin-film microsensors (1)
- typedesign (1)
- voltammetry (1)
- wafer-level testing (1)
- wire frame model (1)
- Öffentlich bestellter Sachverständiger (1)
Ziel und Inhalt dieser Arbeit ist das Design eines Harlekin-Charakters und die Darstellung seiner Ausdrucksskala. Der Schwerpunkt liegt dabei auf dem Studium der Gesichtsmuskeln, ihrer Formensprache und ihrer Relation zu den 6 Grundemotionen Traurigkeit, Ärger, Angst, Freude, Ekel und Überraschung (nach dem Modell von Paul Ekman). Alle 6 Emotionen sind in verschiedenen Intensitätsgraden und Variationen behandelt, wobei die Emotion der Freude aufgrund ihrer engen Bindung zum Harlekin-Charakter vergleichsweise umfassender bearbeitet wurde. Das Endergebnis stellt eine Bildreihe von ca. 50 Ausdrücken und eine Abhandlung über Gesichtsmuskulatur und -ausdruck, dessen Relation zu den Emotionen und den Hintergrund des Harlekincharakters dar. Die Illustrationen wurden unter Verwendung der 3D-Technologie von Maya 7.0 und ZBrush 2.0 ausgeführt.
Study of swift heavy ion modified conduction polymer composites for application as gas sensor
(2006)
A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.
A multi-sensor system is a chemical sensor system which quantitatively and qualitatively records gases with a combination of cross-sensitive gas sensor arrays and pattern recognition software. This paper addresses the issue of data analysis for identification of gases in a gas sensor array. We introduce a software tool for gas sensor array configuration and simulation. It concerns thereby about a modular software package for the acquisition of data of different sensors. A signal evaluation algorithm referred to as matrix method was used specifically for the software tool. This matrix method computes the gas concentrations from the signals of a sensor array. The software tool was used for the simulation of an array of five sensors to determine gas concentration of CH4, NH3, H2, CO and C2H5OH. The results of the present simulated sensor array indicate that the software tool is capable of the following: (a) identify a gas independently of its concentration; (b) estimate the concentration of the gas, even if the system was not previously exposed to this concentration; (c) tell when a gas concentration exceeds a certain value. A gas sensor data base was build for the configuration of the software. With the data base one can create, generate and manage scenarios and source files for the simulation. With the gas sensor data base and the simulation software an on-line Web-based version was developed, with which the user can configure and simulate sensor arrays on-line.
A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polymer membrane was impregnated with tetra-ammine platinum chloride hydrate and the metal ions were subsequently reduced by using either sodium tetrahydroborate or potassium tetrahydroborate. The hydrogen sensing characteristics with air as reference gas is reported. The sensors were capable of detecting hydrogen concentrations from 10 ppm to 10% in nitrogen. The response time was in the range of 10-30 s and a stable linear current output was observed. The thin Pt films were characterized by XRD, Infrared Spectroscopy, Optical Microscopy, Atomic Force Microscopy, Scanning Electron Microscopy and EDAX.
The workflow of a high throughput screening setup for the rapid identification of new and improved sensor materials is presented. The polyol method was applied to prepare nanoparticular metal oxides as base materials, which were functionalised by surface doping. Using multi-electrode substrates and high throughput impedance spectroscopy (HT-IS) a wide range of materials could be screened in a short time. Applying HT-IS in search of new selective gas sensing materials a NO2-tolerant NO sensing material with reduced sensitivities towards other test gases was identified based on iridium doped zinc oxide. Analogous behaviour was observed for iridium doped indium oxide.
Micromachined thermal heater platforms offer low electrical power consumption and high modulation speed, i.e. properties which are advantageous for realizing nondispersive infrared (NDIR) gas- and liquid monitoring systems. In this paper, we report on investigations on silicon-on-insulator (SOI) based infrared (IR) emitter devices heated by employing different kinds of metallic and semiconductor heater materials. Our results clearly reveal the superior high-temperature performance of semiconductor over metallic heater materials. Long-term stable emitter operation in the vicinity of 1300 K could be attained using heavily antimony-doped tin dioxide (SnO2:Sb) heater elements.
Hydrophobic magnetic nanoparticles (NPs) consisting of undecanoate-capped magnetite (Fe3O4, average diameter ca. 5 nm) are used to control quantized electron transfer to surface-confined redox units and metal NPs. A two-phase system consisting of an aqueous electrolyte solution and a toluene phase that includes the suspended undecanoatecapped magnetic NPs is used to control the interfacial properties of the electrode surface. The attracted magnetic NPs form a hydrophobic layer on the electrode surface resulting in the change of the mechanisms of the surface-confined electrochemical processes. A quinone-monolayer modified Au electrode demonstrates an aqueous-type of the electrochemical process (2e-+2H+ redox mechanism) for the quinone units in the absence of the hydrophobic magnetic NPs, while the attraction of the magnetic NPs to the surface results in the stepwise single-electron transfer mechanism characteristic of a dry nonaqueous medium. Also, the attraction of the hydrophobic magnetic NPs to the Au electrode surface modified with Au NPs (ca. 1.4 nm) yields a microenvironment with a low dielectric constant that results in the single-electron quantum charging of the Au NPs.
In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD+, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results obtained by the spectrophotometric method were compared with the results obtained by the colourimetry, using pH indicators. The above-mentioned two methods will be used as references for potentiometric measurements of phenylalanine concentration.
Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations
(2006)
A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors.