Refine
Year of publication
- 2009 (369) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (85)
- Fachbereich Wirtschaftswissenschaften (45)
- IfB - Institut für Bioengineering (40)
- Fachbereich Bauingenieurwesen (38)
- Fachbereich Elektrotechnik und Informationstechnik (38)
- Fachbereich Energietechnik (35)
- INB - Institut für Nano- und Biotechnologien (32)
- Fachbereich Chemie und Biotechnologie (30)
- Fachbereich Maschinenbau und Mechatronik (25)
- Fachbereich Luft- und Raumfahrttechnik (24)
Document Type
- Article (199)
- Conference Proceeding (86)
- Book (32)
- Part of a Book (24)
- Conference: Meeting Abstract (7)
- Doctoral Thesis (5)
- Patent (5)
- Report (5)
- Part of a Periodical (2)
- Working Paper (2)
Keywords
- Blitzschutz (4)
- Fließgewässer (3)
- Geodatenbank (3)
- Geodatenhaltung (3)
- Geoinformationen (3)
- Geoinformationssystem (3)
- Papierkunst (3)
- Aachen / Fachhochschule Aachen (2)
- Aachen University of Applied Sciences (2)
- FH Aachen (2)
An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 µg·l−1 (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels.
In order for traditional masonry to stay a competitive building material in seismically active regions there is an urgent demand for modern, deformation-based verification procedures which exploit the nonlinear load bearing reserves. The Capacity Spectrum Method (CSM) is a widely accepted design approach in the field of reinforced concrete and steel construction. It compares the seismic action with the load-bearing capacity of the building considering nonlinear material behavior with its post-peak capacity. The bearing capacity of the building is calculated iteratively using single wall capacity curves. This paper presents a new approach for the bilinear approximation of single wall capacity curves in the style of EC6/EC8 respectively FEMA 306/FEMA 356 based on recent shear wall test results of the European Collective-Research Project “ESECMaSE”. The application of the CSM to masonry structures by using bilinear approximations of capacity curves as input is demonstrated on the example of a typical German residential home.
A new solar desalination system with heat recovery for decentralised drinking water production
(2009)
A melting probe equipped with autofluorescence-based detection system combined with a light scattering unit, and, optionally, with a microarray chip would be ideally suited to probe icy environments like Europa’s ice layer as well as the polar ice layers of Earth and Mars for recent and extinct live.
The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics.
3D-Imaging
(2009)