Refine
Year of publication
- 2012 (310) (remove)
Document Type
- Article (128)
- Conference Proceeding (89)
- Part of a Book (35)
- Book (26)
- Patent (11)
- Part of Periodical (9)
- Doctoral Thesis (6)
- Report (4)
- Habilitation (1)
- Other (1)
Keywords
- Elektromobilität (7)
- Elektrofahrzeug (5)
- Energieversorgungsnetz (5)
- Kraftfahrzeugelektronik (5)
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (2)
- Elektromobilität; Elektrofahrzeug; Energieversorungsnetz; Kraftfahrzeugtechnik (2)
- (Bio)degradation (1)
- 3. EU Legislativpaket (1)
- 802.15.4 (1)
- Acceleration (1)
- Afterload (1)
- Alginate beads (1)
- Anastomotic leakage (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Avalanche (1)
- Bank-issued Warrants (1)
- Bio-Sensors (1)
- Biosensor (1)
- Bluetooth (1)
- Borehole heat exchanger (1)
- Calorimetric gas sensor (1)
- Cell permeability (1)
- CellDrum (1)
- Cellular force (1)
- Central receiver system (1)
- Chemical imaging sensor (1)
- Circular Dichroism (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Compliance (1)
- Concentrated solar collector (1)
- Consensus (1)
- Contractile tension (1)
- Contractility (1)
- C–V method (1)
- Decomposition (1)
- Detergent protease (1)
- Discourse ethics (1)
- Disposition Effect (1)
- Distributed Control Systems, (1)
- Eisschicht (1)
- Elemental (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Energiewirtschaft (1)
- Esophageal Doppler monitor (1)
- Extracellular enzymes (1)
- FH Aachen (1)
- Fachhochschule Aachen (1)
- Field-effect sensor (1)
- Finite differences (1)
- Finite element modelling (1)
- Force (1)
- Forschungsbericht (1)
- Freeze–thaw process (1)
- Fresnel collector (1)
- Fußball (1)
- Gleichspannungswandler (1)
- Graduiertentagung (1)
- Grid Computing (1)
- Guerrillawerbung (1)
- Heat transport (1)
- Hydrogen peroxide (1)
- Hypersecretion (1)
- IP-based networks (1)
- Impedance spectroscopy (1)
- Individual Investors (1)
- IndraMotion (1)
- Industrial Automation Technology, (1)
- Kinetic energy (1)
- Konsumgesellschaft (1)
- Künstlerisches Handeln (1)
- LAPS (1)
- Light-addressable potentiometric sensor (1)
- Lipopolysaccharide (1)
- Liver (1)
- Low-field NMR (1)
- MATLAB , MLPI , Motion control , Open Core , industrial drives , rapid control prototypin , sercos automation bus (1)
- Marker-free mutagenesis (1)
- Medienforschung (1)
- Motion-Logic System (1)
- NGN (1)
- NMR exchange relaxometry (1)
- NONOate (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanotechnologie (1)
- Negative Feedback Trading (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Numerical linear algebra (1)
- Optical and thermal analysis (1)
- Organic light-emitting diode display (1)
- Ownership Unbundling (1)
- PIV (1)
- PROFINET (1)
- Parasitäre Strategie (1)
- Politische Kunst (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Requirements prioritization (1)
- Requirements relations (1)
- Research Report (1)
- Robotik (1)
- SLM (1)
- SPS (1)
- ScaLAPACK (1)
- Schienbeinschoner (1)
- Selektives Laser Schmelzen (1)
- Silber (1)
- Snow (1)
- Solar concentration (1)
- Sonde (1)
- Speicherprogrammierte Steuerung (1)
- Spleen (1)
- Stenotrophomonas maltophilia (1)
- Sterilisation process (1)
- Stromnetz (1)
- Surgical staplers (1)
- Tool support (1)
- Trading Behavior (1)
- Uracil-phosphoribosyltransferase (1)
- VOF (1)
- Variable height stapler design (1)
- Velocity (1)
- Volume status (1)
- Wireless Networks (1)
- Workflow (1)
- Workflow Orchestration (1)
- Wärmeübertragung (1)
- brachytherapy (1)
- dam-break (1)
- drag force (1)
- eigensolvers (1)
- incontinence (1)
- mobile robots (1)
- next generation network (1)
- numerical model (1)
- performance analysis (1)
- physical model (1)
- product bundling (1)
- prostate cancer (1)
- prostatectomy (1)
- quality of life (1)
- subglacial aquatic ecosystems (1)
- subsurface ice (1)
- telecommunication (1)
- Übertragungsnetz (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (72)
- Fachbereich Wirtschaftswissenschaften (42)
- Fachbereich Elektrotechnik und Informationstechnik (32)
- INB - Institut für Nano- und Biotechnologien (32)
- IfB - Institut für Bioengineering (31)
- Fachbereich Bauingenieurwesen (30)
- Fachbereich Maschinenbau und Mechatronik (29)
- Fachbereich Chemie und Biotechnologie (27)
- Fachbereich Energietechnik (20)
- Solar-Institut Jülich (15)
- Fachbereich Luft- und Raumfahrttechnik (13)
- FH Aachen (12)
- Fachbereich Gestaltung (9)
- Fachbereich Architektur (6)
- Sonstiges (3)
- Freshman Institute (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
- Nowum-Energy (1)
Light-addressable potentiometric sensors (LAPS) are field-effect-based sensors. A modulated light source is used to define the particular measurement spot to perform spatially resolved measurements of chemical species and to generate chemical images. In this work, an organic-LED (OLED) display has been chosen as a light source. This allows high measurement resolution and miniaturisation of the system. A new developed driving method for the OLED display optimised for LAPS-based measurements is demonstrated. The new method enables to define modulation frequencies between 1 kHz and 16 kHz and hence, reduces the measurement time of a chemical image by a factor of 40 compared to the traditional addressing of an OLED display.
The construction of a statistical test is investigated which is based only on “reliability” and “precision” as quality criteria. The reliability of a statistical test is quantifiedin a straightforward way by the probability that the decision of the test is correct. However, the quantification of the precision of a statistical test is not at all evident. Thereforethe paper presents and discusses several approaches. Moreover the distinction of “nullhypothesis” and “alternative hypothesis” is not necessary any longer.
Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface.
This work describes the novel combination of the light-addressable electrode (LAE) and the light-addressable potentiometric sensor (LAPS) into a microsystem set-up. Both the LAE as well as the LAPS shares the principle of addressing the active spot by means of a light beam. This enables both systems to manipulate resp. to detect an analyte with a high spatial resolution. Hence, combining both principles into a single set-up enables the active stimulation e.g., by means of electrolysis and a simultaneous observation e.g., the response of an entrapped biological cell by detection of extracellular pH changes. The work will describe the principles of both technologies and the necessary steps to integrate them into a single set-up. Furthermore, examples of application and operation of such systems will be presented.
Die bauaufsichtliche Einführung der Eurocodes steht unmittelbar bevor. Für den Bereich des Stahl- und Spannbetonbaus soll die Anwendung zum 1. Juli 2012 verbindlich sein, d. h. mit diesem Stichtag sollte nur noch der Eurocode 2 (DIN EN 1992-1-1, Ausgabe Januar 2011) mit seinem zugehörigen nationalen Anhang (DIN EN 1992-1-1/NA, Ausgabe Januar 2011) Verwendung finden, die DIN 1045-1 wird zurückgezogen. Bereits seit März 2010 gilt eine Übergangsphase, ist der die Anwendung des Eurocodes alternativ zur DIN 1045-1 als bauaufsichtlich gleichwertige Lösung möglich.
Beton nach DIN 1045-2
(2012)
Stahlbetonbau
(2012)