Article
Refine
Year of publication
- 2012 (128) (remove)
Document Type
- Article (128) (remove)
Keywords
- (Bio)degradation (1)
- 802.15.4 (1)
- Acceleration (1)
- Afterload (1)
- Alginate beads (1)
- Anastomotic leakage (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Avalanche (1)
- Bank-issued Warrants (1)
- Bluetooth (1)
- Borehole heat exchanger (1)
- Calorimetric gas sensor (1)
- Cell permeability (1)
- CellDrum (1)
- Cellular force (1)
- Chemical imaging sensor (1)
- Circular Dichroism (1)
- Compliance (1)
- Consensus (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (41)
- Fachbereich Wirtschaftswissenschaften (26)
- INB - Institut für Nano- und Biotechnologien (25)
- Fachbereich Chemie und Biotechnologie (15)
- Fachbereich Elektrotechnik und Informationstechnik (14)
- IfB - Institut für Bioengineering (14)
- Fachbereich Maschinenbau und Mechatronik (11)
- Fachbereich Bauingenieurwesen (5)
- Fachbereich Energietechnik (5)
- Fachbereich Architektur (3)
- Fachbereich Luft- und Raumfahrttechnik (3)
- Sonstiges (3)
- Solar-Institut Jülich (2)
- Fachbereich Gestaltung (1)
- Freshman Institute (1)
- Nowum-Energy (1)
Vollzug der Schenkung einer Unterbeteiligung : BGH, Urteil vom 29.11.2011 - II ZR 306/09 : Anmerkung
(2012)
There is common agreement within the scientific community that in order to understand our local galactic environment it will be necessary to send a spacecraft into the region beyond the solar wind termination shock. Considering distances of 200 AU for a new mission, one needs a spacecraft traveling at a speed of close to 10 AU/yr in order to keep the mission duration in the range of less than 25 yrs, a transfer time postulated by European Space Agency (ESA). Two propulsion options for the mission have been proposed and discussed so far: the solar sail propulsion and the ballistic/radioisotope-electric propulsion (REP). As a further alternative, we here investigate a combination of solar-electric propulsion (SEP) and REP. The SEP stage consists of six 22-cms diameter RIT-22 ion thrusters working with a high specific impulse of 7377 s corresponding to a positive grid voltage of 5 kV. Solar power of 53 kW at begin of mission (BOM) is provided by a lightweight solar array.
It is well known that the already large dielectric constants of some electrolytes like BaTiO₃ can be enhanced further by adding metallic (e.g. Ni, Cu or Ag) nanoparticles. The enhancement can be quite large, a factor of more than 1000 is possible. The consequences for the properties will be discussed in the present paper applying a brick-layer model (BLM) for calculating dc-resistivities of thin layers and a modified one (PBLM) that includes percolation for calculating dielectric properties of these materials. The PBLM results in an at least qualitative description and understanding of the physical phenomena: This model gives an explanation for the steep increase of the dielectric constant below the percolation threshold and why this increase is connected to a dramatic decrease of the breakdown voltage as well as the ability of storing electrical energy. We conclude that metallic electrolyte composites like BaTiO₃ are not appropriate for energy storage.
The chemical imaging sensor is a chemical sensor which is capable of visualizing the spatial distribution of chemical species in sample solution. In this study, a novel measurement system based on the chemical imaging sensor was developed to observe the inside of a Y-shaped microfluidic channel while injecting two sample solutions from two branches. From the collected chemical images, it was clearly observed that the injected solutions formed laminar flows in the microfluidic channel. In addition, ion diffusion across the laminar flows was observed. This label-free method can acquire quantitative data of ion distribution and diffusion in microfluidic devices, which can be used to determine the diffusion coefficients, and therefore, the molecular weights of chemical species in the sample solution.
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current–voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.