Refine
Year of publication
- 2013 (301) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- Fachbereich Elektrotechnik und Informationstechnik (43)
- INB - Institut für Nano- und Biotechnologien (40)
- Fachbereich Energietechnik (36)
- Fachbereich Wirtschaftswissenschaften (32)
- Fachbereich Chemie und Biotechnologie (29)
- IfB - Institut für Bioengineering (29)
- Fachbereich Luft- und Raumfahrttechnik (26)
- Fachbereich Bauingenieurwesen (17)
- Fachbereich Maschinenbau und Mechatronik (15)
Document Type
- Article (139)
- Conference Proceeding (77)
- Part of a Book (25)
- Book (24)
- Part of a Periodical (12)
- Report (9)
- Doctoral Thesis (5)
- Patent (4)
- Other (2)
- Conference: Meeting Abstract (1)
Keywords
Architecture for platform- and hardware-independent mesh networks : how to unify the channels
(2013)
This paper will prove that mesh networks among different platforms and hardware channels can help to channel valuable information even if public telecommunication infrastructure is not available due to arbitrary reasons. Therefore, results of a simulation for mesh networks on mass events will be provided, followed by the developed architecture and an outlook on future research. The developed architecture is currently being implemented and field tested on mass events.
In modernen Fahrzeugkarosserien der Großserie kommen zunehmend Materialmischbauweisen
zur Anwendung. In Zusammenarbeit der Daimler AG, der Tower Automotive Holding
GmbH, der Imperia GmbH sowie der Partnerunternehmen KSM Castings GmbH und Schaufler
Tooling GmbH & Co. KG wird das Leichtbaupotenzial von Stahlblech-AluminiumverbundgussHybriden
am Beispiel des vorderen Dachquerträgers des Mercedes-Benz Viano/Vito ausführlich
untersucht.
Purpose
To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T.
Methods
The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study.
Results
Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly.
Conclusion
The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T.