Refine
Year of publication
- 2015 (301) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (70)
- Fachbereich Wirtschaftswissenschaften (42)
- IfB - Institut für Bioengineering (40)
- Fachbereich Elektrotechnik und Informationstechnik (36)
- INB - Institut für Nano- und Biotechnologien (36)
- Fachbereich Luft- und Raumfahrttechnik (32)
- Fachbereich Chemie und Biotechnologie (30)
- Fachbereich Bauingenieurwesen (27)
- Fachbereich Maschinenbau und Mechatronik (26)
- Fachbereich Energietechnik (23)
Document Type
- Article (126)
- Conference Proceeding (92)
- Part of a Book (39)
- Book (22)
- Other (7)
- Report (7)
- Doctoral Thesis (5)
- Patent (2)
- Part of a Periodical (1)
Keywords
- Attitude dynamics (1)
- Booster Station (1)
- Carsharing (1)
- Charging stations (1)
- Discrete Optimisation (1)
- Discrete Optimization (1)
- E-carsharing (1)
- E-mobility (1)
- Efficiency (1)
- Electrical vehicle (1)
The chemical imaging sensor was applied to in-situ pH imaging of the solution in the vicinity of a corroding surface of stainless steel under potentiostatic polarization. A test piece of polished stainless steel was placed on the sensing surface leaving a narrow gap filled with artificial seawater and the stainless steel was corroded under polarization. The pH images obtained during polarization showed correspondence between the region of lower pH and the site of corrosion. It was also found that the pH value in the gap became as low as 2 by polarization, which triggered corrosion.
Designing novel or optimizing existing biodegradable polymers for biomedical applications requires numerous tests on the effect of substances on the degradation process. In the present work, polymer-modified electrolyte–insulator–semiconductor (PMEIS) sensors have been applied for monitoring an enzymatically catalyzed degradation of polymers for the first time. The thin films of biodegradable polymer poly(d,l-lactic acid) and enzyme lipase were used as a model system. During degradation, the sensors were read-out by means of impedance spectroscopy. In order to interpret the data obtained from impedance measurements, an electrical equivalent circuit model was developed. In addition, morphological investigations of the polymer surface have been performed by means of in situ atomic force microscopy. The sensor signal change, which reflects the progress of degradation, indicates an accelerated degradation in the presence of the enzyme compared to hydrolysis in neutral pH buffer media. The degradation rate increases with increasing enzyme concentration. The obtained results demonstrate the potential of PMEIS sensors as a very promising tool for in situ and real-time monitoring of degradation of polymers.
Light-stimulated hydrogel actuators with incorporated graphene oxide for microfluidic applications
(2015)
Changes in intestinal microflora in rats induced by oral exposure to low lead (II) concentrations
(2015)
Attitude and Orbital Dynamics Modeling for an Uncontrolled Solar-Sail Experiment in Low-Earth Orbit
(2015)
Inkompressible Strömungen
(2015)