Refine
Year of publication
- 2015 (301) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (70)
- Fachbereich Wirtschaftswissenschaften (42)
- IfB - Institut für Bioengineering (40)
- Fachbereich Elektrotechnik und Informationstechnik (36)
- INB - Institut für Nano- und Biotechnologien (36)
- Fachbereich Luft- und Raumfahrttechnik (32)
- Fachbereich Chemie und Biotechnologie (30)
- Fachbereich Bauingenieurwesen (27)
- Fachbereich Maschinenbau und Mechatronik (26)
- Fachbereich Energietechnik (23)
Document Type
- Article (126)
- Conference Proceeding (92)
- Part of a Book (39)
- Book (22)
- Other (7)
- Report (7)
- Doctoral Thesis (5)
- Patent (2)
- Part of a Periodical (1)
Keywords
- Attitude dynamics (1)
- Booster Station (1)
- Carsharing (1)
- Charging stations (1)
- Discrete Optimisation (1)
- Discrete Optimization (1)
- E-carsharing (1)
- E-mobility (1)
- Efficiency (1)
- Electrical vehicle (1)
Hollow core fiber delivery of sub-ps pulses from a TruMicro 5000 Femto edition thin disk amplifier
(2015)
Wireless systems for machinery safety : Requirements and solutions for wireless real time systems
(2015)
Globale Stabilitätsanalysen zylindrischer, seismisch belasteter Tanks auf numerischer Grundlage
(2015)
Development and Testing of a Low NOx Micromix Combustion Chamber for an Industrial Gas Turbine
(2015)
Label-free sensing of biomolecules by their intrinsic molecular charge using field-effect devices
(2015)
Unsteady flow measurements in the wake behind a wind-tunnel car model by using high-speed planar PIV
(2015)
This study investigates unsteady characteristics of the wake behind a 28%-scale car model in a wind tunnel using highspeed planar particle image velocimetry (PIV). The car model is based on a hatchback passenger car that is known to have relatively high fluctuations in its aerodynamic loads. This study primarily focuses on the lateral motion of the flow on the horizontal plane to determine the effect of the flow motion on the straight-line stability and the initial steering response of the actual car on a track. This paper first compares the flow fields in the wake behind the above mentioned model obtained using conventional and high-speed planar PIV, with sampling frequencies of 8 Hz and 1 kHz, respectively. Large asymmetrically coherent flow structures, which fluctuate at frequencies below 2 Hz, are observed in the results of highspeed PIV measurements, whereas conventional PIV is unable to capture these features of the flow owing to aliasing. This flow pattern with a laterally swaying motion is represented by opposite signs of cross-correlation coefficients of streamwise velocity fluctuations for the two sides of the car model. Effects of two aerodynamic devices that are known to reduce the
fluctuation levels of the aerodynamic loads are then extensively investigated. The correlation analyses reveal that these devices indeed reduce the fluctuation levels of the flow and the correlation values around the rear combination-lamp, but it is found that the effects of these devices are different around the c-pillar.
The sterilization of packages in aseptic food processes is highly significant to maintain a consumer-safe product with extended shelf-life. Today, the sterilization of food packages is predominantly accomplished by gaseous hydrogen peroxide (H2O2) in combination with heat. In order to monitor this sterilization process, calorimetric gas sensors as differential set-up of two platinum temperature sensors representing a catalytically active (additionally deposition of MnO2) and a passive segment have been recently developed. The temperature rise of the exothermic decomposition serves as an indicator of the present H2O2 concentration. In the present work, a theoretical approach considering the sensor’s thermochemistry and physical transport phenomena was formulated to evaluate the temperature rise based on the energy content of gaseous H2O2. In a further part of this work, three polymers have been analyzed with respect to their application as passivation materials. The examined polymers are photoresist SU-8, perfluoroalkoxy (PFA) and fluorinated ethylene propylene (FEP). Thermal analyses by means of differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) have been conducted to determine the operation limits of the polymers. The overall chemical resistance and stability of the polymers against the harsh environmental conditions during the sterilization process have been examined by attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR).
The chemical imaging sensor was applied to in-situ pH imaging of the solution in the vicinity of a corroding surface of stainless steel under potentiostatic polarization. A test piece of polished stainless steel was placed on the sensing surface leaving a narrow gap filled with artificial seawater and the stainless steel was corroded under polarization. The pH images obtained during polarization showed correspondence between the region of lower pH and the site of corrosion. It was also found that the pH value in the gap became as low as 2 by polarization, which triggered corrosion.
Designing novel or optimizing existing biodegradable polymers for biomedical applications requires numerous tests on the effect of substances on the degradation process. In the present work, polymer-modified electrolyte–insulator–semiconductor (PMEIS) sensors have been applied for monitoring an enzymatically catalyzed degradation of polymers for the first time. The thin films of biodegradable polymer poly(d,l-lactic acid) and enzyme lipase were used as a model system. During degradation, the sensors were read-out by means of impedance spectroscopy. In order to interpret the data obtained from impedance measurements, an electrical equivalent circuit model was developed. In addition, morphological investigations of the polymer surface have been performed by means of in situ atomic force microscopy. The sensor signal change, which reflects the progress of degradation, indicates an accelerated degradation in the presence of the enzyme compared to hydrolysis in neutral pH buffer media. The degradation rate increases with increasing enzyme concentration. The obtained results demonstrate the potential of PMEIS sensors as a very promising tool for in situ and real-time monitoring of degradation of polymers.
Light-stimulated hydrogel actuators with incorporated graphene oxide for microfluidic applications
(2015)
Changes in intestinal microflora in rats induced by oral exposure to low lead (II) concentrations
(2015)
Attitude and Orbital Dynamics Modeling for an Uncontrolled Solar-Sail Experiment in Low-Earth Orbit
(2015)
Inkompressible Strömungen
(2015)
The Scarab Project
(2015)
Urban Search and Rescue (USAR) is an active research
field in the robotics community. Despite recent advances
for many open research questions, these kind of systems are
not widely used in real rescue missions. One reason is that such
systems are complex and not (yet) very reliable; another is that
one has to be an robotic expert to run such a system. Moreover,
available rescue robots are very expensive and the benefits of
using them are still limited.
In this paper, we present the Scarab robot, an alternative
design for a USAR robot. The robot is light weight, humanpackable
and its primary purpose is that of extending the
rescuer’s capability to sense the disaster site. The idea is that a
responder throws the robot to a certain spot. The robot survives
the impact with the ground and relays sensor data such as
camera images or thermal images to the responder’s hand-held
control unit from which the robot can be remotely controlled.
Mechatronics consist of the integration of mechanical
engineering, electronic integration and computer science/
engineering. These broad fields are essential for robotic
systems, yet it makes it difficult for the researchers to specialize
and be experts in all these fields. Collaboration between
researchers allow for the integration of experience and specialization,
to allow optimized systems. Collaboration between the
European countries and South Africa is critical, as each country
has different resources available, which the other countries
might not have. Applications with the need for approval of
any restrictions, can also be obtained easier in some countries
compared to others, thus preventing the delays of research.
Some problems that have been experienced are discussed, with
the Robotics Center of South Africa as a possible solution.
With autonomous mobile robots receiving increased
attention in industrial contexts, the need for benchmarks
becomes more and more an urgent matter. The RoboCup
Logistics League (RCLL) is one specific industry-inspired scenario
focusing on production logistics within a Smart Factory.
In this paper, we describe how the RCLL allows to assess the
performance of a group of robots within the scenario as a
whole, focusing specifically on the coordination and cooperation
strategies and the methods and components to achieve them.
We report on recent efforts to analyze performance of teams in
2014 to understand the implications of the current grading
scheme, and derived criteria and metrics for performance
assessment based on Key Performance Indicators (KPI) adapted
from classic factory evaluation. We reflect on differences and
compatibility towards RoCKIn, a recent major benchmarking
European project.