• Treffer 2 von 248
Zurück zur Trefferliste

Non-invasive evaluation of neurovascular coupling in the murine retina by dynamic retinal vessel analysis

  • Background Impairment of neurovascular coupling (NVC) was recently reported in the context of subarachnoid hemorrhage and may correlate with disease severity and outcome. However, previous techniques to evaluate NVC required invasive procedures. Retinal vessels may represent an alternative option for non-invasive assessment of NVC. Methods A prototype of an adapted retinal vessel analyzer was used to assess retinal vessel diameter in mice. Dynamic vessel analysis (DVA) included an application of monochromatic flicker light impulses in predefined frequencies for evaluating NVC. All retinae were harvested after DVA and electroretinograms were performed. Results A total of 104 retinal scans were conducted in 21 male mice (90 scans). Quantitative arterial recordings were feasible only in a minority of animals, showing an emphasized reaction to flicker light impulses (8 mice; 14 scans). A characteristic venous response to flicker light, however, could observed in the majority of animals. Repeated measurements resulted in a significant decrease of baseline venous diameter (7 mice; 7 scans, p < 0.05). Ex-vivo electroretinograms, performed after in-vivo DVA, demonstrated a significant reduction of transretinal signaling in animals with repeated DVA (n = 6, p < 0.001). Conclusions To the best of our knowledge, this is the first non-invasive study assessing murine retinal vessel response to flicker light with characteristic changes in NVC. The imaging system can be used for basic research and enables the investigation of retinal vessel dimension and function in control mice and genetically modified animals.

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar
Metadaten
Verfasserangaben:Walid Albanna, Konstantin KotliarORCiD, Jan Niklas Lüke, Serdar Alpdogan, Catharina Conzen, Ute Lindauer, Hans Clusmann, Jürgen Hescheler, Walthard Vilser, Toni Schneider, Gerrit Alexander Schubert
DOI:https://doi.org/10.1371/journal.pone.0204689
Titel des übergeordneten Werkes (Englisch):Plos one
Verlag:PLOS
Verlagsort:San Francisco
Dokumentart:Wissenschaftlicher Artikel
Sprache:Englisch
Erscheinungsjahr:2018
Datum der Publikation (Server):25.10.2018
Jahrgang:13
Ausgabe / Heft:10
Umfang:e0204689
Link:https://doi.org/10.1371/journal.pone.0204689
Zugriffsart:weltweit
Fachbereiche und Einrichtungen:FH Aachen / Fachbereich Medizintechnik und Technomathematik
FH Aachen / IfB - Institut für Bioengineering
collections:Verlag / PLOS
Open Access / Gold
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung