Refine
Year of publication
Document Type
- Article (132)
- Conference Proceeding (62)
- Part of a Book (13)
- Book (4)
- Lecture (3)
- Other (3)
- Report (2)
- Doctoral Thesis (1)
- Patent (1)
- Review (1)
Keywords
- Finite-Elemente-Methode (16)
- Einspielen <Werkstoff> (13)
- shakedown analysis (9)
- FEM (6)
- Limit analysis (6)
- Shakedown analysis (6)
- limit analysis (6)
- Einspielanalyse (4)
- Shakedown (4)
- Technische Mechanik (4)
- Traglast (4)
- Traglastanalyse (4)
- shakedown (4)
- ratchetting (3)
- Analytischer Zulaessigkeitsnachweis (2)
- Biocomposites (2)
- Bruchmechanik (2)
- Druckbeanspruchung (2)
- Druckbehälter (2)
- Druckbelastung (2)
- Einspiel-Analyse (2)
- Fehlerstellen (2)
- Natural fibres (2)
- Polymer-matrix composites (2)
- Ratcheting (2)
- Rohr (2)
- Rohrbruch (2)
- Stahl (2)
- Stress concentrations (2)
- burst pressure (2)
- burst tests (2)
- damage (2)
- flaw (2)
- limit load (2)
- load limit (2)
- pipes (2)
- tension–torsion loading (2)
- vessels (2)
- Alternating plasticity (1)
- Anastomose (1)
- Anastomosis (1)
- Anastomotic leakage (1)
- Arthosetherapie (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bicharakteristikenverfahren (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Bladder (1)
- Bone sawing (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Chance constrained programming (1)
- Collagen fibrils (1)
- Computational biomechanics (1)
- Connective tissues (1)
- Constitutive model (1)
- Convex optimization (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Deformation (1)
- Design-by-analysis (1)
- Discontinuous fractures (1)
- Distorsion des oberen Sprunggelenks (1)
- Druckgeräte (1)
- Drug simulation (1)
- ES-FEM (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elastodynamik (1)
- Elastostatics (1)
- Electromechanical modeling (1)
- End-to-end colorectal anastomosis (1)
- Evolution of damage (1)
- Exact Ilyushin yield surface (1)
- Extension fracture (1)
- Extension strain criterion (1)
- Extracellular matrix (ECM) (1)
- FEM-Programm (1)
- FEM-computation (1)
- FS-FEM (1)
- Festkörper (1)
- Finite element analysis (1)
- Finite element analysis (FEA) (1)
- Finite element method (1)
- Finite element modelling (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fließgrenze (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Fußball (1)
- Global and local collapse (1)
- Gonarthrose (1)
- Grenzwertberechnung (1)
- Growth modelling (1)
- Heart tissue culture (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Ion channels (1)
- Kinematics (1)
- Kinetics (1)
- Kniegelenkarthrose (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- LISA (1)
- Liver (1)
- MBST (1)
- Materialermüdung (1)
- Mechanical simulation (1)
- Mechanical stability (1)
- Mechanics (1)
- Mohr–Coulomb criterion (1)
- Multi-dimensional wave propagation (1)
- Multimode failure (1)
- Muscle fibers (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Non-linear optimization (1)
- Non-parallel fissures (1)
- PFM (1)
- Passive stretching (1)
- Pelvic floor dysfunction (1)
- Pelvic muscle (1)
- Pharmacology (1)
- Plastizität (1)
- Pressure loaded crack-face (1)
- Progressive plastic deformation (1)
- Random variable (1)
- Ratchetting (1)
- Reconstruction (1)
- Reliability analysis (1)
- Reliability of structures (1)
- S-FEM (1)
- Schienbeinschoner (1)
- Schwammknochen (1)
- Sensitivity (1)
- Shakedown criterion (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Statics (1)
- Stochastic programming (1)
- Strukturanalyse (1)
- Surgical staplers (1)
- Tapered ends (1)
- Temperaturabhängigkeit (1)
- Torsion (1)
- Torsionsbelastung (1)
- Tragfähigkeit (1)
- Uniaxial compression test (1)
- Ureter (1)
- Variable height stapler design (1)
- Wellen (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Zug-Druck Belastung (1)
- Zug-Druck-Beanspruchung (1)
- Zug-Druck-Belastung (1)
- alternierend Verformbarkeit (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- arthrosis therapy (1)
- biaxial tensile experiment (1)
- bicharacteristics (1)
- bone density (1)
- bone structure (1)
- cancellous bone (1)
- chance constrained programming (1)
- constitutive modeling (1)
- dental trauma (1)
- design-by-analysis (1)
- difficult airway (1)
- direct method (1)
- distorted element (1)
- double-lumen tube intubation (1)
- elastic solids (1)
- fatigue analyses (1)
- fibulare Bandruptur (1)
- finite element analysis (1)
- fortschreitende plastische Deformation (1)
- gonarthrosis (1)
- hiPS cardiomyocytes (1)
- hyperelastic (1)
- konvexe Optimierung (1)
- limit and shakedown analysis (1)
- linear kinematic hardening (1)
- load carrying capacity (1)
- lower bound theorem (1)
- material shakedown (1)
- mechanical waves (1)
- non-simplex S-FEM elements (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- plastic deformation (1)
- probabilistic fracture mechanics (1)
- reliability (1)
- reliability analysis (1)
- reliability of structures (1)
- rupture of the fibular ligament (1)
- second-order reliability method (1)
- shakedown analyses (1)
- smooth muscle contraction (1)
- stochastic programming (1)
- strain energy function (1)
- thermal ratcheting (1)
- training simulator (1)
- videolaryngoscopy (1)
- virgin passive (1)
- virtual reality (1)
- viscoelasticity (1)
- yield stress (1)
Background/Aims: Common systems for the quantification of cellular contraction rely on animal-based models, complex experimental setups or indirect approaches. The herein presented CellDrum technology for testing mechanical tension of cellular monolayers and thin tissue constructs has the potential to scale-up mechanical testing towards medium-throughput analyses. Using hiPS-Cardiac Myocytes (hiPS-CMs) it represents a new perspective of drug testing and brings us closer to personalized drug medication. Methods: In the present study, monolayers of self-beating hiPS-CMs were grown on ultra-thin circular silicone membranes and deflect under the weight of the culture medium. Rhythmic contractions of the hiPS-CMs induced variations of the membrane deflection. The recorded contraction-relaxation-cycles were analyzed with respect to their amplitudes, durations, time integrals and frequencies. Besides unstimulated force and tensile stress, we investigated the effects of agonists and antagonists acting on Ca²⁺ channels (S-Bay K8644/verapamil) and Na⁺ channels (veratridine/lidocaine). Results: The measured data and simulations for pharmacologically unstimulated contraction resembled findings in native human heart tissue, while the pharmacological dose-response curves were highly accurate and consistent with reference data. Conclusion: We conclude that the combination of the CellDrum with hiPS-CMs offers a fast, facile and precise system for pharmacological, toxicological studies and offers new preclinical basic research potential.
Reconstructive surgery and tissue replacements like ureters or bladders reconstruction have been recently studied, taking into account growth and remodelling of cells since living cells are capable of growing, adapting, remodelling or degrading and restoring in order to deform and respond to stimuli. Hence, shapes of ureters or bladders and their microstructure change during growth and these changes strongly depend on external stimuli such as training. We present the mechanical stimulation of smooth muscle cells in a tubular fibrin-PVDFA scaffold and the modelling of the growth of tissue by stimuli. To this end, mechanotransduction was performed with a kyphoplasty balloon catheter that was guided through the lumen of the tubular structure. The bursting pressure was examined to compare the stability of the incubated tissue constructs. The results showed the significant changes on tissues with training by increasing the burst pressure as a characteristic mechanical property and the smooth muscle cells were more oriented with uniformly higher density. Besides, the computational growth models also exhibited the accurate tendencies of growth of the cells under different external stimuli. Such models may lead to design standards for the better layered tissue structure in reconstructing of tubular organs characterized as composite materials such as intestines, ureters and arteries.
We present an electromechanically coupled Finite Element model for cardiac tissue. It bases on the mechanical model for cardiac tissue of Hunter et al. that we couple to the McAllister-Noble-Tsien electrophysiological model of purkinje fibre cells. The corresponding system of ordinary differential equations is implemented on the level of the constitutive equations in a geometrically and physically nonlinear version of the so-called edge-based smoothed FEM for plates. Mechanical material parameters are determined from our own pressure-deflection experimental setup. The main purpose of the model is to further examine the experimental results not only on mechanical but also on electrophysiological level down to ion channel gates. Moreover, we present first drug treatment simulations and validate the model with respect to the experiments.
We present an electromechanically coupled computational model for the investigation of a thin cardiac tissue construct consisting of human-induced pluripotent stem cell-derived atrial, ventricular and sinoatrial cardiomyocytes. The mechanical and electrophysiological parts of the finite element model, as well as their coupling are explained in detail. The model is implemented in the open source finite element code Code_Aster and is employed for the simulation of a thin circular membrane deflected by a monolayer of autonomously beating, circular, thin cardiac tissue. Two cardio-active drugs, S-Bay K8644 and veratridine, are applied in experiments and simulations and are investigated with respect to their chronotropic effects on the tissue. These results demonstrate the potential of coupled micro- and macroscopic electromechanical models of cardiac tissue to be adapted to experimental results at the cellular level. Further model improvements are discussed taking into account experimentally measurable quantities that can easily be extracted from the obtained experimental results. The goal is to estimate the potential to adapt the presented model to sample specific cell cultures.
Soft Materials in Technology and Biology – Characteristics, Properties, and Parameter Identification
(2008)
An optimization method is developed to describe the mechanical behaviour of the human cancellous bone. The method is based on a mixture theory. A careful observation of the behaviour of the bone material leads to the hypothesis that the bone density is controlled by the principal stress trajectories (Wolff’s law). The basic idea of the developed method is the coupling of a scalar value via an eigenvalue problem to the principal stress trajectories. On the one hand this theory will permit a prediction of the reaction of the biological bone structure after the implantation of a prosthesis, on the other hand it may be useful in engineering optimization problems. An analytical example shows its efficiency.