Refine
Year of publication
- 2022 (22) (remove)
Document Type
- Conference Proceeding (13)
- Article (6)
- Part of a Book (3)
Keywords
- Concentrated solar power (3)
- Energy storage (3)
- Hybrid energy system (3)
- Electricity generation (2)
- Power plants (2)
- Solar thermal technologies (2)
- Associated liquids (1)
- Brake set-up (1)
- Brake test (1)
- Camera system (1)
- Ceramics (1)
- Cloud passages (1)
- Conpot (1)
- Control optimization (1)
- Cybersecurity (1)
- Cybersicherheit (1)
- DNI forecast (1)
- DNI forecasting (1)
- Direct normal irradiance forecast (1)
- Dynamic simulation (1)
Institute
- ECSM European Center for Sustainable Mobility (22) (remove)
Having well-defined control strategies for fuel cells, that can efficiently detect errors and take corrective action is critically important for safety in all applications, and especially so in aviation. The algorithms not only ensure operator safety by monitoring the fuel cell and connected components, but also contribute to extending the health of the fuel cell, its durability and safe operation over its lifetime. While sensors are used to provide peripheral data surrounding the fuel cell, the internal states of the fuel cell cannot be directly measured. To overcome this restriction, Kalman Filter has been implemented as an internal state observer.
Other safety conditions are evaluated using real-time data from every connected sensor and corrective actions automatically take place to ensure safety. The algorithms discussed in this paper have been validated thorough Model-in-the-Loop (MiL) tests as well as practical validation at a dedicated test bench.
Concentrated Solar Power (CSP) systems are able to store energy cost-effectively in their integrated thermal energy storage (TES). By intelligently combining Photovoltaics (PV) systems with CSP, a further cost reduction of solar power plants is expected, as well as an increase in dispatchability and flexibility of power generation. PV-powered Resistance Heaters (RH) can be deployed to raise the temperature of the molten salt hot storage from 385 °C up to 565 °C in a Parabolic Trough Collector (PTC) plant. To avoid freezing and decomposition of molten salt, the temperature distribution in the electrical resistance heater is investigated in the present study. For this purpose, a RH has been modeled and CFD simulations have been performed. The simulation results show that the hottest regions occur on the electric rod surface behind the last baffle. A technical optimization was performed by adjusting three parameters: Shell-baffle clearance, electric rod-baffle clearance and number of baffles. After the technical optimization was carried out, the temperature difference between the maximum temperature and the average outlet temperature of the salt is within the acceptable limits, thus critical salt decomposition has been avoided. Additionally, the CFD simulations results were analyzed and compared with results obtained with a one-dimensional model in Modelica.