Refine
Year of publication
Document Type
- Conference Proceeding (148) (remove)
Has Fulltext
- no (148) (remove)
Keywords
- Natural language processing (4)
- Clustering (2)
- Information extraction (2)
- Active learning (1)
- Agent-based simulation (1)
- Chance constrained programming (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Deep learning (1)
- EEG (1)
- Energy market design (1)
- Evolution of damage (1)
- Extension fracture (1)
- Extension strain criterion (1)
- Force (1)
- Grid Computing (1)
- Impedance Spectroscopy (1)
- Information Extraction (1)
- Iterative learning control (1)
- Knee (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (148) (remove)
An application of a scanning light-addressable potentiometric sensor for label-free DNA detection
(2013)
Reliable methods for automatic readability assessment have the potential to impact a variety of fields, ranging from machine translation to self-informed learning. Recently, large language models for the German language (such as GBERT and GPT-2-Wechsel) have become available, allowing to develop Deep Learning based approaches that promise to further improve automatic readability assessment. In this contribution, we studied the ability of ensembles of fine-tuned GBERT and GPT-2-Wechsel models to reliably predict the readability of German sentences. We combined these models with linguistic features and investigated the dependence of prediction performance on ensemble size and composition. Mixed ensembles of GBERT and GPT-2-Wechsel performed better than ensembles of the same size consisting of only GBERT or GPT-2-Wechsel models. Our models were evaluated in the GermEval 2022 Shared Task on Text Complexity Assessment on data of German sentences. On out-of-sample data, our best ensemble achieved a root mean squared error of 0:435.
The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent.