Refine
Year of publication
Document Type
- Article (5464) (remove)
Language
Has Fulltext
- no (5464) (remove)
Keywords
- avalanche (5)
- Earthquake (4)
- LAPS (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
- snow (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Chemometrics (2)
- Datenschutz (2)
- Datenschutzgrundverordnung (2)
- Drinfeld modules (2)
- Empirical process (2)
- Field-effect sensor (2)
- Goodness-of-fit test (2)
Institute
- Fachbereich Medizintechnik und Technomathematik (1531)
- Fachbereich Wirtschaftswissenschaften (683)
- Fachbereich Elektrotechnik und Informationstechnik (617)
- Fachbereich Energietechnik (597)
- Fachbereich Chemie und Biotechnologie (585)
- INB - Institut für Nano- und Biotechnologien (523)
- Fachbereich Maschinenbau und Mechatronik (463)
- IfB - Institut für Bioengineering (426)
- Fachbereich Luft- und Raumfahrttechnik (364)
- Fachbereich Bauingenieurwesen (324)
- Solar-Institut Jülich (105)
- Fachbereich Architektur (76)
- Fachbereich Gestaltung (55)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (39)
- ECSM European Center for Sustainable Mobility (33)
- Nowum-Energy (28)
- Sonstiges (23)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (18)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (15)
NMR standardization approach that uses the 2H integral of deuterated solvent for quantitative multinuclear analysis of pharmaceuticals is described. As a proof of principle, the existing NMR procedure for the analysis of heparin products according to US Pharmacopeia monograph is extended to the determination of Na+ and Cl- content in this matrix. Quantification is performed based on the ratio of a 23Na (35Cl) NMR integral and 2H NMR signal of deuterated solvent, D2O, acquired using the specific spectrometer hardware. As an alternative, the possibility of 133Cs standardization using the addition of Cs2CO3 stock solution is shown. Validation characteristics (linearity, repeatability, sensitivity) are evaluated. A holistic NMR profiling of heparin products can now also be used for the quantitative determination of inorganic compounds in a single analytical run using a single sample. In general, the new standardization methodology provides an appealing alternative for the NMR screening of inorganic and organic components in pharmaceutical products.
Multimodal bioimage sensor
(2014)
To visualize the biochemical distribution two-dimensionally, we invented a solid-state-type ion image sensor that indicates the chemical activity of solutions and cells. The device, which consists of a CCD array covered with a functionalized membrane to detect charge accumulation, is highly sensitive to changes in the concentration and two-dimensional distribution of ions and biomaterials.
Cheap does not imply cost-effective -- this is rule number one of zeitgeisty system design. The initial investment accounts only for a small portion of the lifecycle costs of a technical system. In fluid systems, about ninety percent of the total costs are caused by other factors like power consumption and maintenance. With modern optimization methods, it is already possible to plan an optimal technical system considering multiple objectives. In this paper, we focus on an often neglected contribution to the lifecycle costs: downtime costs due to spontaneous failures. Consequently, availability becomes an issue.
In this work, a multi-sensor chip for the investigation of the sensing properties of different types of metal oxides towards hydrogen peroxide in the ppm range is presented. The fabrication process and physical characterization of the multi-sensor chip are described. Pure SnO2 and WO3 as well as Pd- and Pt-doped SnO2 films are characterized in terms of their sensitivity to H2O2. The sensing films have been prepared by drop-coating of water-dispensed nano-powders. A physical characterization, including scanning electron microscopy and X-ray diffraction analysis of the deposited metal-oxide films, was done. From the measurements in hydrogen peroxide atmosphere, it could be shown, that all of the tested metal oxide films are suitable for the detection of H2O2 in the ppm range. The highest sensitivity and reproducibility was achieved using Pt-doped SnO2.
Calibration plot of a SnO2, WO3, Pt-, and Pd-doped SnO2 gas sensor for H2O2 concentrations in the ppm range.