Refine
Year of publication
- 2018 (255) (remove)
Document Type
- Article (124)
- Conference Proceeding (77)
- Part of a Book (30)
- Book (12)
- Working Paper (3)
- Doctoral Thesis (2)
- Other (2)
- Patent (2)
- Part of Periodical (2)
- Report (1)
Keywords
- Datenschutz (2)
- Digitale Transformation (2)
- Energy efficiency (2)
- Engineering optimization (2)
- Literaturanalyse (2)
- MINLP (2)
- Pump System (2)
- Serious Game (2)
- Water (2)
- Agility (1)
- Antarctica (1)
- Awareness (1)
- Bahadur efficiency (1)
- Bioethanol (1)
- Biorefinery (1)
- Bladder (1)
- Booster Stations (1)
- Buffering Capacity (1)
- CDG (1)
- Chance Constraint (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (67)
- Fachbereich Elektrotechnik und Informationstechnik (44)
- IfB - Institut für Bioengineering (41)
- INB - Institut für Nano- und Biotechnologien (25)
- Fachbereich Luft- und Raumfahrttechnik (24)
- Fachbereich Maschinenbau und Mechatronik (24)
- Fachbereich Energietechnik (22)
- Fachbereich Wirtschaftswissenschaften (21)
- Fachbereich Chemie und Biotechnologie (18)
- Fachbereich Bauingenieurwesen (16)
- Fachbereich Architektur (8)
- ECSM European Center for Sustainable Mobility (6)
- Solar-Institut Jülich (5)
- Fachbereich Gestaltung (4)
- Institut fuer Angewandte Polymerchemie (3)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (2)
- Nowum-Energy (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- FH Aachen (1)
68Ga-radiopharmaceuticals are common in the field of Nuclear Medicine to visualize receptor-mediated processes. In contrast to straightforward labeling procedures for clinical applications, preclinical in vitro and in vivo applications are hampered for reasons like e.g. volume
restriction, activity concentration, molar activity and osmolality. Therefore, we developed a semiautomatic system specifically to overcome these problems. A difficulty appeared unexpectedly, as intrinsic trace metals derived from eluate (Zn, Fe and Cu) are concentrated as well in amounts that influence radiochemical yield and thus lower molar activity.
Seismic design of buried pipeline systems for energy and water supply is not only important for plant and operational safety but also for the maintenance of the supply infrastructure after an earthquake. The present paper shows special issues of the seismic wave impacts on buried pipelines, describes calculation methods, proposes approaches and gives calculation examples. This paper regards the effects of transient displacement differences and resulting tensions within the pipeline due to the wave propagation of the earthquake. However, the presented model can also be used to calculate fault rupture induced displacements. Based on a three-dimensional Finite Element Model parameter studies are performed to show the influence of several parameters such as incoming wave angle, wave velocity, backfill height and synthetic displacement time histories. The interaction between the pipeline and the surrounding soil is modeled with non-linear soil springs and the propagating wave is simulated affecting the pipeline punctually, independently in time and space. Special attention is given to long-distance heat pipeline systems. Here, in regular distances expansion bends are arranged to ensure movements of the pipeline due to high temperature. Such expansion bends are usually designed with small bending radii, which during the earthquake lead to high bending stresses in the cross-section of the pipeline. Finally, an interpretation of the results and recommendations are given for the most critical parameters.
The quest for life on other planets is closely connected with the search for water in liquid state. Recent discoveries of deep oceans on icy moons like Europa and Enceladus have spurred an intensive discussion about how these waters can be accessed. The challenge of this endeavor lies in the unforeseeable requirements on instrumental characteristics both with respect to the scientific and technical methods. The TRIPLE/nanoAUV initiative is aiming at developing a mission concept for exploring exo-oceans and demonstrating the achievements in an earth-analogue context, exploring the ocean under the ice shield of Antarctica and lakes like Dome-C on the Antarctic continent.
Schwellenreiten
(2018)
This work demonstrates how the interaction between particle image velocimetry (PIV) and robotics can massively increase measurement efficiency. The interdisciplinary approach is shown using the complex example of an automated, large scale, industrial environment: a typical automotive wind tunnel application. Both the high degree of flexibility in choosing the measurement region and the complete automation of stereo PIV measurements are presented. The setup consists of a combination of three robots, individually used as a 6D traversing unit for the laser illumination system as well as for each of the two cameras. Synchronised movements in the same reference frame are realised through a master-slave setup with a single interface to the user. By integrating the interface into the standard wind tunnel management system, a single measurement plane or a predefined sequence of several planes can be requested through a single trigger event, providing the resulting vector fields within minutes.
In this paper, a brief overview on the demands of large scale industrial PIV and the existing solutions is given. Afterwards, the concept of RoboPIV is introduced as a new approach. In a first step, the usability of a selection of commercially available robot arms is analysed. The challenges of pose uncertainty and importance of absolute accuracy are demonstrated through comparative measurements, explaining the individual pros and cons of the analysed systems. Subsequently, the advantage of integrating RoboPIV directly into the existing wind tunnel management system is shown on basis of a typical measurement sequence. In a final step, a practical measurement procedure, including post-processing, is given by using real data and results. Ultimately, the benefits of high automation are demonstrated, leading to a drastic reduction in necessary measurement time compared to non-automated systems, thus massively increasing the efficiency of PIV measurements.