Refine
Year of publication
Document Type
- Conference Proceeding (227) (remove)
Language
- English (130)
- German (95)
- Multiple languages (1)
- Spanish (1)
Has Fulltext
- yes (227) (remove)
Keywords
- Biosensor (25)
- Blitzschutz (15)
- CAD (11)
- Finite-Elemente-Methode (11)
- civil engineering (11)
- Bauingenieurwesen (10)
- Lightning protection (9)
- Einspielen <Werkstoff> (6)
- Telekommunikationsmarkt (6)
- shakedown analysis (6)
- Graduiertentagung (5)
- Clusterion (4)
- Führung (4)
- Kanalisation (4)
- Leadership (4)
- Sonde (4)
- limit analysis (4)
- reinforced concrete (4)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (3)
- Absolvententreffen (3)
Institute
- Fachbereich Medizintechnik und Technomathematik (91)
- IfB - Institut für Bioengineering (38)
- Fachbereich Bauingenieurwesen (36)
- Fachbereich Energietechnik (33)
- Fachbereich Maschinenbau und Mechatronik (19)
- Fachbereich Elektrotechnik und Informationstechnik (16)
- Fachbereich Wirtschaftswissenschaften (15)
- Fachbereich Luft- und Raumfahrttechnik (11)
- INB - Institut für Nano- und Biotechnologien (11)
- FH Aachen (6)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (4)
- Solar-Institut Jülich (3)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- Fachbereich Chemie und Biotechnologie (1)
- Fachbereich Gestaltung (1)
"[...] Der erste Teil des Vortags konzentriert sich auf die bei Ericsson gemachten Erfahrungen. Welche Muster wurden identifiziert, für welche Tests wurden sie eingesetzt. Wie werden diese Muster verwendet, wie werden sie beschrieben und spezifiziert. Und schließlich, wie entsteht eine Art Standardisierung, in der das Wissen über diese Muster als Organisationswissen zur Verfügung steht.
Im zweiten Teil des Vortrags werden die bei Ericsson gemachten Erfahrungen verallgemeinert. Die bei Ericsson verwendeten Muster werden auf allgemeine Strukturen übertragen (z.B. Client-Server). Es wird gezeigt, wie die Zuordnung von Testverfahren auf Netzwerkmuster auch in anderen Domänen verwendet wird und welche Vorteile sich damit erzielen lassen."
Quelle: http://www.qs-tag.de/fileadmin/software-qs-tag/public/2007/abstract_jacobs.shtml
The determination of spacing, edge and end distance requirements for self-tapping screws requires numerous and comprehensive insertion tests. Yet the results of such tests cannot be transferred to other types of screws or even to screws of different diameter because of differences in shape or geometry. To reduce the effort of insertion tests a new method was developed which allows the estimation of required spacings, distances and timber thickness.
Recently, the SHARP Corporation, Japan, has developed the world’s first "Plasma Cluster Ions (PCI)" air purification technology using plasma discharge to generate cluster ions. The new plasma cluster device releases positive and negative ions into the air, which are able to decompose and deactivate harmful airborne substances by chemical reactions. Because cluster ions consist of positive and negative ions that normally exist in the natural world, they are completely harmless and safe to humans. The amount of ozone generated by cluster ions is less than 0.01 ppm, which is significantly less than the 0.05-ppm standard for industrial operations and consumer electronics. This amount, thus, has no harming effects whatsoever on the human body. But particular properties and chemical processes in PCI treatment are still under study. It has been shown that PCI in most cases show strongly pronounced irreversible killing effects in respect of airborne microflora due to free-radical induced reactions and can be considered as a potent technology to disinfect both home, medical and industrial appliances.
Summary and Conclusions PCIs were clearly effective in terms of their antibacterial effects with the strains tested. This efficacy increased with the time the bacteries were exposed to PCIs. The bactericidal action has proved to be irreversible. PCIs were significantly less effective in shadowed areas. PCI exposure caused multiple protein damages as observed in SDS PAGE studies. There was no single but multiple molecular mechanism causing the bacterial death.
Recently, SHARP corporation has developed the world’s first “Plasma Cluster Ions (PCI)” air purification technology, which uses plasma discharge to generate cluster ions. The new plasma cluster device releases into the air positive and negative ions, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. A lot of phenomenological tests of the PCI air purification technology on microbial cells have been conducted. And, in most cases, it has been shown that PCI demonstrate strongly pronounced killing effect. Although, the particular mechanisms of PCI action are still not evident. We studied variations in resistance to PCI among gram-positive airborne microorganisms, as well as some dose-dependent, spatial, cultural and biochemical properties of PCI action in respect of Staphylococcus spp, Enterococcus spp, Micrococcus spp.
Recently, SHARP corporation has developed the world’s first "Plasma Cluster Ions® (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new Plasma Cluster Device releases positive and negative ions into the air, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. In the past, phenomenological tests on the efficacy of the PCI air purification technology on microbial cells have been conducted. In most cases, it has been shown that PCI demonstrated strongly pronounced killing effects on microorganisms. However, the particular mechanisms of PCI action still have to be uncovered.
Mechanical stimulation of the cells resulted in evident changes in the cell morphology, protein composition and gene expression. Microscopically, additional formation of stress fibers accompanied by cell re-arrangements in a monolayer was observed. Also, significant activation of p53 gene was revealed as compared to control. Interestingly, the use of CellTech membrane coating induced cell death after mechanical stress had been applied. Such an effect was not detected when fibronectin had been used as an adhesion substrate.