Refine
Year of publication
Document Type
- Conference Proceeding (227) (remove)
Language
- English (130)
- German (95)
- Multiple languages (1)
- Spanish (1)
Has Fulltext
- yes (227) (remove)
Keywords
- Biosensor (25)
- Blitzschutz (15)
- CAD (11)
- Finite-Elemente-Methode (11)
- civil engineering (11)
- Bauingenieurwesen (10)
- Lightning protection (9)
- Einspielen <Werkstoff> (6)
- Telekommunikationsmarkt (6)
- shakedown analysis (6)
- Graduiertentagung (5)
- Clusterion (4)
- Führung (4)
- Kanalisation (4)
- Leadership (4)
- Sonde (4)
- limit analysis (4)
- reinforced concrete (4)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (3)
- Absolvententreffen (3)
Institute
- Fachbereich Medizintechnik und Technomathematik (91)
- IfB - Institut für Bioengineering (38)
- Fachbereich Bauingenieurwesen (36)
- Fachbereich Energietechnik (33)
- Fachbereich Maschinenbau und Mechatronik (19)
- Fachbereich Elektrotechnik und Informationstechnik (16)
- Fachbereich Wirtschaftswissenschaften (15)
- Fachbereich Luft- und Raumfahrttechnik (11)
- INB - Institut für Nano- und Biotechnologien (11)
- FH Aachen (6)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (4)
- Solar-Institut Jülich (3)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- Fachbereich Chemie und Biotechnologie (1)
- Fachbereich Gestaltung (1)
The paper deals with the development of the probabilistic approach to the assessment of risk due to lightning. Sources of damage, types of damage and types of loss are defined and, accordingly, the procedure for risk analysis and the way of assessment of different risk components is proposed. The way to evaluate the influence of different protection measures (lightning protection system; shielding of structure, cables and equipment; routing of internal wiring; surge protective device) in reducing such probabilities is considered. The paper has been prepared within the framework of the activity of IEC TC81-WG9/CLC TC81-WG4 directed to prepare the draft IEC 62305-2 Risk Management, in cooperation with the Secretary of IEC/CLC TC81.
Funktionsprinzip Emissionsrechtehandel, Betroffene Anlagen und Branchen, Erstverteilung der Emissionsrechte, Bereits erbrachte Emissionsreduktionen (early actions), Ausstieg von betroffenen Unternehmen (opt-out), Teilnahme von nicht betroffenen Unternehmen, Einsatz von Biobrennstoffen, Erfassung und Dokumentation der Emissionen
Ausgangslage, Funktionsprinzip des virtuellen Kraftwerkes, Energiemanagementsysteme (EMS), Einsatzgebiete, Anlagesysteme eines VKW's, Einsatzbereich der verschiedenen dezentralen Energieanlagen, Vorteile des virtuellen Kraftwerkes, Auswirkungen auf das elektrische Netz, Wirtschaftliche Aspekte, Beispielprojekte
A melting probe equipped with autofluorescence-based detection system combined with a light scattering unit, and, optionally, with a microarray chip would be ideally suited to probe icy environments like Europa’s ice layer as well as the polar ice layers of Earth and Mars for recent and extinct live.
Mechanical stimulation of the cells resulted in evident changes in the cell morphology, protein composition and gene expression. Microscopically, additional formation of stress fibers accompanied by cell re-arrangements in a monolayer was observed. Also, significant activation of p53 gene was revealed as compared to control. Interestingly, the use of CellTech membrane coating induced cell death after mechanical stress had been applied. Such an effect was not detected when fibronectin had been used as an adhesion substrate.
Recently, SHARP corporation has developed the world’s first “Plasma Cluster Ions (PCI)” air purification technology, which uses plasma discharge to generate cluster ions. The new plasma cluster device releases into the air positive and negative ions, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. A lot of phenomenological tests of the PCI air purification technology on microbial cells have been conducted. And, in most cases, it has been shown that PCI demonstrate strongly pronounced killing effect. Although, the particular mechanisms of PCI action are still not evident. We studied variations in resistance to PCI among gram-positive airborne microorganisms, as well as some dose-dependent, spatial, cultural and biochemical properties of PCI action in respect of Staphylococcus spp, Enterococcus spp, Micrococcus spp.
Summary and Conclusions PCIs were clearly effective in terms of their antibacterial effects with the strains tested. This efficacy increased with the time the bacteries were exposed to PCIs. The bactericidal action has proved to be irreversible. PCIs were significantly less effective in shadowed areas. PCI exposure caused multiple protein damages as observed in SDS PAGE studies. There was no single but multiple molecular mechanism causing the bacterial death.
Recently, the SHARP Corporation, Japan, has developed the world’s first "Plasma Cluster Ions (PCI)" air purification technology using plasma discharge to generate cluster ions. The new plasma cluster device releases positive and negative ions into the air, which are able to decompose and deactivate harmful airborne substances by chemical reactions. Because cluster ions consist of positive and negative ions that normally exist in the natural world, they are completely harmless and safe to humans. The amount of ozone generated by cluster ions is less than 0.01 ppm, which is significantly less than the 0.05-ppm standard for industrial operations and consumer electronics. This amount, thus, has no harming effects whatsoever on the human body. But particular properties and chemical processes in PCI treatment are still under study. It has been shown that PCI in most cases show strongly pronounced irreversible killing effects in respect of airborne microflora due to free-radical induced reactions and can be considered as a potent technology to disinfect both home, medical and industrial appliances.
Recently, SHARP corporation has developed the world’s first "Plasma Cluster Ions® (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new Plasma Cluster Device releases positive and negative ions into the air, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. In the past, phenomenological tests on the efficacy of the PCI air purification technology on microbial cells have been conducted. In most cases, it has been shown that PCI demonstrated strongly pronounced killing effects on microorganisms. However, the particular mechanisms of PCI action still have to be uncovered.
Mit freundlicher Genehmigung der Autoren und des Oldenbourg Industrieverlags https://www.oldenbourg-industrieverlag.de/de/9783835633223-33223 erschienen als Beitrag im Tagungsband zur AALE-Tagung 2012. 9. Fachkonferenz 4.-5. Mai 2012, Aachen, Fachhochschule. ISBN 9783835633223 S 2-1 S. 37-46 Original-Abstract der Autoren: "Dieser Artikel beschreibt eine universelle Programmierschnittstelle zur Entwicklung von Motion-Logic Applikationen für industrielle Motion-Controller. Sie ermöglicht die Entwicklung von Software mit modernen Hochsprachen, wie C/C++. Visual Basic, C#, Java, Objective-Cund visuellen Programmiersprachen, wie LabVIEW in Koexistenz mit klassischen Programmiersprachen für speicherprogrammierbare Steuerungen nach IEC 61131-3. Daraus ergeben sich neue Möglichkeiten industrielle Antriebs- und Steuerungssysteme mit ihrem IT-Umfeld zu verbinden."
Mit freundlicher Genehmigung der Autoren und des Oldenbourg Industrieverlags https://www.oldenbourg-industrieverlag.de/de/9783835633223-33223 erschienen als Beitrag im Tagungsband zur AALE-Tagung 2012. 9. Fachkonferenz 4.-5. Mai 2012, Aachen, Fachhochschule. ISBN 9783835633223 S 6-2. S. 165-174 Zusammenfassung der Autoren: "Abschließend kann festgehalten werden, dass die gesamten durchgeführten Überlegungen von den Messergebnissen der Inbetriebnahme positiv bestätigt werden. Es wird durch diese Topologie eine maximale Systemverfügbarkeit garantiert und die Zellen werden optimal betrieben. Ein Blick in die Zukunft für dieses Projekt zeigt viele Erweiterungs- und Optimierungsaufgaben. So muss der DC/DC-Wandler für einen bidirektionalen Betrieb erweitert werden, um einen Rekuperationsbetrieb zu gewährleisten bzw. die Zellen laden zu können. Dadurch können gleichzeitig die Gleichrichterdioden im Sekundärleistungsteil durch IGBTs oder MOSFETs ersetzt werden. Die voll funktionsfähige Version des DC/DC-Wandlers könnte höchstwahrscheinlich direkt auf die Anschlusspole der Zelle montiert werden, wodurch das Gewicht gesenkt wird. Durch die verringerte Verlustleistung in den Zuleitungen könnte der Wirkungsgrad noch einmal gesteigert werden.
Dipl.-Ing. Ralf Engels - DHI Wasser und Umwelt GmbH, Syke. 24 S. (S. 70-93) Beitrag zum 1. Aachener Softwaretag in der Wasserwirtschaft <1,2007, Aachen> Einleitung [des Autors] Die hydrodynamische Kanalnetzmodellierung ist ein Standardwerkzeug für die Bemessung von Kanalnetzen. Neben der Berechnung der hydrologischen und hydraulischen Gegebenheiten in einem städtischen Einzugsgebiet gehören auch weiterführende Technologien mittlerweile zum Standard. So können alle steuerbaren Elemente eines Kanalnetzes dynamisch so optimiert werden, dass die Leistungsfähigkeit des Kanalnetzes zusätzlich gesteigert werden kann. Automatische Werkzeuge zur dynamischen hydraulischen Schmutzfrachtberechnung ermöglichen die Erweiterung der Steuerung – insbesondere von Entlastungsanlagen – im Hinblick auf die entlasteten Schmutzfrachten und geben darüber hinaus detaillierte Informationen für den Betrieb der Kläranlage. Weiterführende biologische Prozessmodellierungen ergänzen dieses Themenfeld. GIS Werkzeuge können bei der räumlich differenzierten Modellierung von Kanalnetzen wertvolle Dienste leisten. Die detaillierte Betrachtung einzelner Haltungsflächen in ihrem räumlichen Zusammenhang ist damit ebenso möglich wie eine komplette Verwaltung aller für die Kanalnetzmodellierung notwendigen Daten in einem übersichtlichen grafischen Menü. Die Grenzen der Kanalnetzmodellierung lagen in früheren Zeiten an dessen Rand. Detaillierte Informationen über die Wege des Wassers auf der Geländeoberfläche, an der Schnittstelle zu Vorflutern und in der Interaktion mit Grundwasser waren bisher nicht modelltechnisch bewertbar. Eine dynamische Kopplung verschiedener Modelle zur Darstellung aller relevanten hydraulischen Prozesse ermöglicht eine integrative Betrachtung aller möglichen Wege, die das Wasser in der Stadt nehmen kann (Mark & Djordjevic, 2006). Dieser Beitrag präsentiert den Stand der Technik für die integrierte Modellierung städtischer Überschwemmungen mit Hilfe der Modellkopplung von Oberflächenmodellen und Kanalnetzmodellen.