Refine
Year of publication
- 2022 (2)
- 2021 (1)
- 2020 (1)
- 2019 (1)
- 2018 (2)
- 2017 (1)
- 2016 (2)
- 2015 (1)
- 2014 (1)
- 2013 (3)
- 2012 (3)
- 2011 (11)
- 2010 (7)
- 2009 (9)
- 2008 (11)
- 2007 (6)
- 2005 (1)
- 2004 (7)
- 2003 (4)
- 2002 (4)
- 2001 (2)
- 2000 (8)
- 1999 (3)
- 1998 (4)
- 1997 (1)
- 1996 (2)
- 1995 (1)
- 1994 (1)
- 1993 (1)
- 1991 (3)
- 1990 (2)
- 1988 (4)
- 1987 (2)
- 1986 (1)
Document Type
- Article (87)
- Conference Proceeding (14)
- Report (5)
- Book (3)
- Part of a Book (2)
- Doctoral Thesis (1)
- Habilitation (1)
Keywords
- Clusterion (5)
- Air purification (4)
- Hämoglobin (4)
- Luftreiniger (4)
- Plasmacluster ion technology (4)
- Raumluft (4)
- CellDrum (3)
- Lipopolysaccharide (3)
- Sonde (3)
- Eisschicht (2)
- Erythrozyt (2)
- Kohlenstofffaser (2)
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- lipopolysaccharides (2)
- nanostructured carbonized plant parts (2)
- nanostrukturierte carbonisierte Pflanzenteile (2)
- plant scanner (2)
- Autofluoreszenzverfahren (1)
- Bakterien (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (113) (remove)
Mechano-pharmacological testing of L-Type Ca²⁺ channel modulators via human vascular celldrum model
(2020)
Background/Aims: This study aimed to establish a precise and well-defined working model, assessing pharmaceutical effects on vascular smooth muscle cell monolayer in-vitro. It describes various analysis techniques to determine the most suitable to measure the biomechanical impact of vasoactive agents by using CellDrum technology. Methods: The so-called CellDrum technology was applied to analyse the biomechanical properties of confluent human aorta muscle cells (haSMC) in monolayer. The cell generated tensions deviations in the range of a few N/m² are evaluated by the CellDrum technology. This study focuses on the dilative and contractive effects of L-type Ca²⁺ channel agonists and antagonists, respectively. We analyzed the effects of Bay K8644, nifedipine and verapamil. Three different measurement modes were developed and applied to determine the most appropriate analysis technique for the study purpose. These three operation modes are called, particular time mode" (PTM), "long term mode" (LTM) and "real-time mode" (RTM). Results: It was possible to quantify the biomechanical response of haSMCs to the addition of vasoactive agents using CellDrum technology. Due to the supplementation of 100nM Bay K8644, the tension increased approximately 10.6% from initial tension maximum, whereas, the treatment with nifedipine and verapamil caused a significant decrease in cellular tension: 10nM nifedipine decreased the biomechanical stress around 6,5% and 50nM verapamil by 2,8%, compared to the initial tension maximum. Additionally, all tested measurement modes provide similar results while focusing on different analysis parameters. Conclusion: The CellDrum technology allows highly sensitive biomechanical stress measurements of cultured haSMC monolayers. The mechanical stress responses evoked by the application of vasoactive calcium channel modulators were quantified functionally (N/m²). All tested operation modes resulted in equal findings, whereas each mode features operation-related data analysis.
We present the novel concept of a combined drilling and melting probe for subsurface ice research. This probe, named “IceMole”, is currently developed, built, and tested at the FH Aachen University of Applied Sciences’ Astronautical Laboratory. Here, we describe its first prototype design and report the results of its field tests on the Swiss Morteratsch glacier. Although the IceMole design is currently adapted to terrestrial glaciers and ice shields, it may later be modified for the subsurface in-situ investigation of extraterrestrial ice, e.g., on Mars, Europa, and Enceladus. If life exists on those bodies, it may be present in the ice (as life can also be found in the deep ice of Earth).
A melting probe equipped with autofluorescence-based detection system combined with a light scattering unit, and, optionally, with a microarray chip would be ideally suited to probe icy environments like Europa’s ice layer as well as the polar ice layers of Earth and Mars for recent and extinct live.
Changes in intestinal microflora in rats induced by oral exposure to low lead (II) concentrations
(2015)
Recently, SHARP corporation has developed the world’s first “Plasma Cluster Ions (PCI)” air purification technology, which uses plasma discharge to generate cluster ions. The new plasma cluster device releases into the air positive and negative ions, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. A lot of phenomenological tests of the PCI air purification technology on microbial cells have been conducted. And, in most cases, it has been shown that PCI demonstrate strongly pronounced killing effect. Although, the particular mechanisms of PCI action are still not evident. We studied variations in resistance to PCI among gram-positive airborne microorganisms, as well as some dose-dependent, spatial, cultural and biochemical properties of PCI action in respect of Staphylococcus spp, Enterococcus spp, Micrococcus spp.
Summary and Conclusions PCIs were clearly effective in terms of their antibacterial effects with the strains tested. This efficacy increased with the time the bacteries were exposed to PCIs. The bactericidal action has proved to be irreversible. PCIs were significantly less effective in shadowed areas. PCI exposure caused multiple protein damages as observed in SDS PAGE studies. There was no single but multiple molecular mechanism causing the bacterial death.
Recently, the SHARP Corporation, Japan, has developed the world’s first "Plasma Cluster Ions (PCI)" air purification technology using plasma discharge to generate cluster ions. The new plasma cluster device releases positive and negative ions into the air, which are able to decompose and deactivate harmful airborne substances by chemical reactions. Because cluster ions consist of positive and negative ions that normally exist in the natural world, they are completely harmless and safe to humans. The amount of ozone generated by cluster ions is less than 0.01 ppm, which is significantly less than the 0.05-ppm standard for industrial operations and consumer electronics. This amount, thus, has no harming effects whatsoever on the human body. But particular properties and chemical processes in PCI treatment are still under study. It has been shown that PCI in most cases show strongly pronounced irreversible killing effects in respect of airborne microflora due to free-radical induced reactions and can be considered as a potent technology to disinfect both home, medical and industrial appliances.
Recently, SHARP corporation has developed the world’s first "Plasma Cluster Ions® (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new Plasma Cluster Device releases positive and negative ions into the air, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. In the past, phenomenological tests on the efficacy of the PCI air purification technology on microbial cells have been conducted. In most cases, it has been shown that PCI demonstrated strongly pronounced killing effects on microorganisms. However, the particular mechanisms of PCI action still have to be uncovered.
Reconstructive surgery and tissue replacements like ureters or bladders reconstruction have been recently studied, taking into account growth and remodelling of cells since living cells are capable of growing, adapting, remodelling or degrading and restoring in order to deform and respond to stimuli. Hence, shapes of ureters or bladders and their microstructure change during growth and these changes strongly depend on external stimuli such as training. We present the mechanical stimulation of smooth muscle cells in a tubular fibrin-PVDFA scaffold and the modelling of the growth of tissue by stimuli. To this end, mechanotransduction was performed with a kyphoplasty balloon catheter that was guided through the lumen of the tubular structure. The bursting pressure was examined to compare the stability of the incubated tissue constructs. The results showed the significant changes on tissues with training by increasing the burst pressure as a characteristic mechanical property and the smooth muscle cells were more oriented with uniformly higher density. Besides, the computational growth models also exhibited the accurate tendencies of growth of the cells under different external stimuli. Such models may lead to design standards for the better layered tissue structure in reconstructing of tubular organs characterized as composite materials such as intestines, ureters and arteries.