Refine
Year of publication
- 2009 (360) (remove)
Document Type
- Article (198)
- Conference Proceeding (85)
- Book (32)
- Part of a Book (24)
- Doctoral Thesis (5)
- Patent (5)
- Report (5)
- Part of Periodical (2)
- Working Paper (2)
- Diploma Thesis (1)
- Talk (1)
Keywords
- Blitzschutz (4)
- Fließgewässer (3)
- Geodatenbank (3)
- Geodatenhaltung (3)
- Geoinformationen (3)
- Geoinformationssystem (3)
- Papierkunst (3)
- Aachen / Fachhochschule Aachen (2)
- Aachen University of Applied Sciences (2)
- FH Aachen (2)
- Renaturierung <Ökologie> (2)
- Spacecraft (2)
- Stickstoffmonoxid (2)
- Wasserwirtschaft (2)
- nitric oxide gas (2)
- Aachen / Fachhochschule Aachen ; Graduierter ; Promotionsstudium (1)
- Adsorption (1)
- Aktionskunst (1)
- Atomausstieg (1)
- Autofluoreszenzverfahren (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (85)
- Fachbereich Wirtschaftswissenschaften (45)
- IfB - Institut für Bioengineering (39)
- Fachbereich Bauingenieurwesen (38)
- Fachbereich Elektrotechnik und Informationstechnik (36)
- Fachbereich Energietechnik (35)
- INB - Institut für Nano- und Biotechnologien (32)
- Fachbereich Maschinenbau und Mechatronik (25)
- Fachbereich Chemie und Biotechnologie (24)
- Solar-Institut Jülich (24)
- Fachbereich Luft- und Raumfahrttechnik (23)
- Fachbereich Architektur (9)
- Fachbereich Gestaltung (7)
- FH Aachen (3)
- Kommission für Forschung und Entwicklung (3)
- ECSM European Center for Sustainable Mobility (2)
- Freshman Institute (2)
- Nowum-Energy (2)
- Sonstiges (2)
- Verwaltung (2)
An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 µg·l−1 (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels.
Kommentierung zu §§ 705-740
(2009)
Density Operator
(2009)
Operator
(2009)
Projection
(2009)
Self-Adjoint Operator
(2009)
Unitary Operator
(2009)
Siedlungswasserwirtschaft
(2009)
The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics.
Dr.-Ing. Oliver Stoschek [u.a.] DHI Wasser und Umwelt GmbH, Syke. 14 S. (S. 45-58). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen> Ökologische Modelle zur Berechnung der Temperaturveränderung und den Einfluss von Kühlwasser auf die Wassertemperatur der Elbe. Die vorgelegte Arbeit wurde beauftragt und unterstützt von der ARGE Elbe im Zuge der Neuauflage des Wärmelastplans Elbe.