Refine
Year of publication
Document Type
- Conference Proceeding (1146) (remove)
Language
- English (1146) (remove)
Keywords
- Biosensor (25)
- CAD (7)
- Finite-Elemente-Methode (7)
- civil engineering (7)
- Bauingenieurwesen (6)
- Blitzschutz (6)
- Enterprise Architecture (5)
- Clusterion (4)
- Energy storage (4)
- Gamification (4)
- Leadership (4)
- Limit analysis (4)
- Natural language processing (4)
- Power plants (4)
- Sonde (4)
- Telekommunikationsmarkt (4)
- hydrogen (4)
- solar sail (4)
- Air purification (3)
- Associated liquids (3)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (230)
- Fachbereich Medizintechnik und Technomathematik (208)
- Fachbereich Luft- und Raumfahrttechnik (178)
- Fachbereich Energietechnik (177)
- IfB - Institut für Bioengineering (147)
- Solar-Institut Jülich (110)
- Fachbereich Maschinenbau und Mechatronik (107)
- Fachbereich Bauingenieurwesen (73)
- Fachbereich Wirtschaftswissenschaften (51)
- ECSM European Center for Sustainable Mobility (50)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (46)
- INB - Institut für Nano- und Biotechnologien (39)
- Fachbereich Chemie und Biotechnologie (23)
- Kommission für Forschung und Entwicklung (16)
- Nowum-Energy (11)
- Fachbereich Architektur (7)
- Fachbereich Gestaltung (4)
- Institut fuer Angewandte Polymerchemie (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
Lightning protection design of a renewable energy hybrid-system without power mains connection
(2001)
In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.
In: Advances in intelligent computing in engineering : proceedings of the 9.International EG-ICE Workshop ; Darmstadt, (01 - 03 August) 2002 / Martina Schnellenbach-Held ... (eds.) . - Düsseldorf: VDI-Verl., 2002 .- Fortschritt-Berichte VDI, Reihe 4, Bauingenieurwesen ; 180 ; S. 1-35 The paper describes a novel way to support conceptual design in civil engineering. The designer uses semantical tools guaranteeing certain internal structures of the design result but also the fulfillment of various constraints. Two different approaches and corresponding tools are discussed: (a) Visually specified tools with automatic code generation to determine a design structure as well as fixing various constraints a design has to obey. These tools are also valuable for design knowledge specialist. (b) Extensions of existing CAD tools to provide semantical knowledge to be used by an architect. It is sketched how these different tools can be combined in the future. The main part of the paper discusses the concepts and realization of two prototypes following the two above approaches. The paper especially discusses that specific graphs and the specification of their structure are useful for both tool realization projects.