Refine
Year of publication
Document Type
- Article (3226) (remove)
Language
- English (3226) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- biosensors (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- Label-free detection (3)
- additive manufacturing (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
- shakedown analysis (3)
- snow (3)
- tobacco mosaic virus (TMV) (3)
- Acyl-amino acids (2)
Institute
- Fachbereich Medizintechnik und Technomathematik (1343)
- INB - Institut für Nano- und Biotechnologien (501)
- Fachbereich Chemie und Biotechnologie (466)
- IfB - Institut für Bioengineering (408)
- Fachbereich Elektrotechnik und Informationstechnik (401)
- Fachbereich Energietechnik (360)
- Fachbereich Luft- und Raumfahrttechnik (247)
- Fachbereich Maschinenbau und Mechatronik (147)
- Fachbereich Wirtschaftswissenschaften (106)
- Fachbereich Bauingenieurwesen (68)
- Solar-Institut Jülich (43)
- ECSM European Center for Sustainable Mobility (27)
- Sonstiges (21)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (17)
- Nowum-Energy (16)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (15)
- Fachbereich Gestaltung (12)
- Fachbereich Architektur (9)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (5)
Objective:
To develop a transmit/receive radiofrequency (RF) array for magnetic resonance imaging (MRI) of the carotid arteries at 7 T. The prototype is characterized in numerical simulations and bench measurements, and the feasibility of plaque imaging at 7 T is demonstrated in first in vivo images.
Materials and Methods:
The RF phased array coil consists of 8 surface loop coils. To allow imaging of both sides of the neck, the RF array is divided into 2 coil clusters, each with 4 overlapping loop elements. For safety validation, numerical computations of the RF field distribution and the corresponding specific absorption rate were performed on the basis of a heterogeneous human body model. To validate the coil model, maps of the transmit B1+ field were compared between simulation and measurement. In vivo images of a healthy volunteer and a patient (ulcerating plaque and a 50% stenosis of the right internal carotid artery) were acquired using a 3-dimensional FLASH sequence with a high isotropic spatial resolution of 0.54 mm as well as using pulse-triggered proton density (PD)/T2-weighted turbo spin echo sequences.
Results:
Measurements of the S-parameters yielded a reflection and isolation of the coil elements of better than −18 and −13 dB, respectively. Measurements of the g-factor indicated good image quality for parallel imaging acceleration factors up to 2.4. A similar distribution and a very good match of the absolute values were found between the measured and simulated B1+ transmit RF field for the validation of the coil model. In vivo images revealed good signal excitation of both sides of the neck and a high vessel-to-background image contrast for the noncontrast-enhanced 3-dimensional FLASH sequence. Imaging at 7 T could depict the extent of stenosis, and revealed the disruption and ulcer of the plaque.
Conclusions:
This study demonstrates that 2 four-channel transmit/receive RF arrays for each side of the neck is a suitable concept for in vivo MRI of the carotid arteries at 7 Tesla. Further studies are needed to explore and exploit the full potential of 7 T high-field MRI for carotid atherosclerotic plaque imaging.
Quantitative nuclear magnetic resonance (qNMR) is considered as a powerful tool for multicomponent mixture analysis as well as for the purity determination of single compounds. Special attention is currently paid to the training of operators and study directors involved in qNMR testing. To assure that only qualified personnel are used for sample preparation at our GxP-accredited laboratory, weighing test was proposed. Sixteen participants performed six-fold weighing of the binary mixture of dibutylated hydroxytoluene (BHT) and 1,2,4,5-tetrachloro-3-nitrobenzene (TCNB). To evaluate the quality of data analysis, all spectra were evaluated manually by a qNMR expert and using in-house developed automated routine. The results revealed that mean values are comparable and both evaluation approaches are free of systematic error. However, automated evaluation resulted in an approximately 20% increase in precision. The same findings were revealed for qNMR analysis of 32 compounds used in pharmaceutical industry. Weighing test by six-fold determination in binary mixtures and automated qNMR methodology can be recommended as efficient tools for evaluating staff proficiency. The automated qNMR method significantly increases throughput and precision of qNMR for routine measurements and extends application scope of qNMR.
This paper introduces a new maritime search and rescue system based on S-band illumination harmonic radar (HR). Passive and active tags have been developed and tested while attached to life jackets and a small boat. In this demonstration test carried out on the Baltic Sea, the system was able to detect and range the active tags up to a distance of 5800 m using an illumination signal transmit-power of 100 W. Special attention is given to the development, performance, and conceptual differences between passive and active tags used in the system. Guidelines for achieving a high HR dynamic range, including a system components description, are given and a comparison with other HR systems is performed. System integration with a commercial maritime X-band navigation radar is shown to demonstrate a solution for rapid search and rescue response and quick localization.