Refine
Year of publication
Document Type
- Article (542)
- Conference Proceeding (63)
- Part of a Book (11)
- Book (2)
- Other (2)
- Report (2)
- Patent (1)
Language
- English (551)
- German (71)
- Multiple languages (1)
Keywords
- Biosensor (7)
- Graduiertentagung (5)
- LAPS (4)
- field-effect sensor (4)
- hydrogen peroxide (4)
- Field-effect sensor (3)
- Label-free detection (3)
- Light-addressable potentiometric sensor (3)
- biosensors (3)
- capacitive field-effect sensor (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Calorimetric gas sensor (2)
- Capacitive field-effect sensor (2)
- Graduate symposium (2)
- Hydrogen peroxide (2)
- Raman spectroscopy (2)
- Tobacco mosaic virus (TMV) (2)
- acetoin (2)
- capacitive field-effect sensors (2)
- gold nanoparticles (2)
- light-addressable potentiometric sensor (2)
- penicillinase (2)
- sterilisation (2)
- (Bio)degradation (1)
- Aachen / Fachhochschule Aachen (1)
- Aachen / Fachhochschule Aachen ; Graduierter ; Promotionsstudium (1)
- Bacillus atrophaeus spores (1)
- Bio-Sensors (1)
- Bioabsorbable (1)
- Biomolecular logic gate (1)
- Biophoton (1)
- Biosensorik (1)
- CNOT (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Chemical images (1)
- Chemical imaging (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Coat protein (1)
- C–V method (1)
- DNA (1)
- DNA biosensor (1)
- DNA hybridization (1)
- DPA (dipicolinic acid) (1)
- Dehydrogenase (1)
- Diaphorase (1)
- EIS capacitive sensor (1)
- Electrolyte–insulator–semiconductor (1)
- Enzymatic biosensor (1)
- Enzyme biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme nanocarrier (1)
- Field effect (1)
- Field-effect biosensor (1)
- Field-effect device (1)
- Gas sensor (1)
- Glucose biosensor (1)
- Glucose oxidase (1)
- Gold nanoparticle (1)
- Gold nanoparticles (1)
- Graduierter (1)
- Heavy metal detection (1)
- I3S 2005 (1)
- ISFET (1)
- Impedance spectroscopy (1)
- International Symposium on Sensor Science (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- Light-addressable Potentiometric Sensor (1)
- MEMS (1)
- MOS (1)
- Multi-sensor system (1)
- Multianalyte detection (1)
- Multicell (1)
- Multiplexing (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Negative impedance convertor (1)
- O2 plasma (1)
- Organic light-emitting diode display (1)
- Penicillin (1)
- Plant virus (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polylactide acid (1)
- Potentiometry (1)
- Promotionsstudium (1)
- Real-time monitoring (1)
- Resistive temperature detector (1)
- Resonance-mode measurement (1)
- Silk fibroin (1)
- Simultaneous determination (1)
- Sn₃O₄ (1)
- Sterilisation process (1)
- Supraleiter (1)
- TMV adsorption (1)
- Ta₂O₅ gate (1)
- Tobacco mosaic virus (1)
- Wafer (1)
- XOR (1)
- Zeta potential (1)
- acetoin reductase (1)
- actuator-sensor system (1)
- alcoholic beverages (1)
- aminooctanethiol (1)
- amperometric biosensors (1)
- annealing (1)
- artificial olfactory image (1)
- aseptic parameters (1)
- atomic layer deposition (1)
- barium strontium titanate (1)
- bi-enzyme biosensor (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- biosensor (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive EIS sensor (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capacitive field-effect biosensor (1)
- capacitive model (1)
- capillary micro-droplet cell (1)
- carbon electrodes (1)
- catalytic decomposition (1)
- catalytic metal (1)
- chemical sensor (1)
- contactless conductivity sensor (1)
- control gate (1)
- detection of charged macromolecules (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electrolyte-insulator-semiconductor capacitors (1)
- electronic nose (1)
- encapsulation materials (1)
- endospores (1)
- enzymatic (bio)degradation (1)
- enzymatic biosensor (1)
- enzyme cascade (1)
- enzyme immobilization (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- equivalent circuit (1)
- fibroin (1)
- field-effect structure (1)
- gas sensor (1)
- gaseous hydrogen peroxide (1)
- glucose (1)
- glucose oxidase (GOx) (1)
- graphene oxide (1)
- heavy metals (1)
- high-k material (1)
- horseradish peroxidase (HRP) (1)
- hydroxylation (1)
- immobilization (1)
- impedance spectroscopy (1)
- in-situ monitoring (1)
- lable-free detection (1)
- layer expansion (1)
- layer-by-layer technique (1)
- light-addressable electrode (1)
- light-addressing technologies (1)
- metal-oxide-semiconductor structure (1)
- microfluidics (1)
- multi-functional material (1)
- multi-sensing platform (1)
- multianalyte detection (1)
- nanobelts (1)
- nanomaterials (1)
- nanoparticle coverage (1)
- novel photoexcitation method (1)
- on-chip integrated addressable EISCAP sensors (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organic PVC membranes (1)
- organosilanes (1)
- pH sensors (1)
- pattern-size reduction (1)
- penicillin (1)
- photoelectrochemistry (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- poly(d, l-lactic acid) (1)
- polyaniline (1)
- polystyrene sulfonate (1)
- scanned light pulse technique (1)
- self-aligned patterning (1)
- silanization (1)
- spatial resolution (1)
- spore kill rate (1)
- sterility (1)
- sterility tests (1)
- sterilization (1)
- sterilization conditions (1)
- sterilization efficacy (1)
- sterilization methods (1)
- surface functionalization (1)
- temperature (1)
- thin-film microsensors (1)
- tilted constant illumination (1)
- titanium dioxide photoanode (1)
- turnip vein clearing virus (TVCV) (1)
- ultrathin gate insulators (1)
- urease (1)
- validation methods (1)
- visualization (1)
- wafer-level testing (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (603)
- INB - Institut für Nano- und Biotechnologien (526)
- Fachbereich Chemie und Biotechnologie (40)
- FH Aachen (5)
- Nowum-Energy (5)
- Fachbereich Energietechnik (4)
- Institut fuer Angewandte Polymerchemie (3)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- Fachbereich Elektrotechnik und Informationstechnik (1)
An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM.
A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, “fluidic-channel”-, “cantilever”- and meander-type structures.
Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations
(2006)
A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors.
A multi-spot (16 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure modified with a weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)) was applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. To achieve a preferentially flat orientation of DNA strands and thus, to reduce the distance between the DNA charge and MLAPS surface, the negatively charged probe single-stranded DNAs (ssDNA) were electrostatically adsorbed onto the positively charged PAH layer using a simple layer-by-layer (LbL) technique. In this way, more DNA charge can be positioned within the Debye length, yielding a higher sensor signal. The surface potential changes in each spot induced due to the surface modification steps (PAH adsorption, probe ssDNA immobilization, hybridization with complementary target DNA (cDNA), non-specific adsorption of mismatched ssDNA) were determined from the shifts of photocurrent–voltage curves along the voltage axis. A high sensor signal of 83 mV was registered after immobilization of probe ssDNA onto the PAH layer. The hybridization signal increases from 5 mV to 32 mV with increasing the concentration of cDNA from 0.1 nM to 5 μM. In contrast, a small signal of 5 mV was recorded in the case of non-specific adsorption of fully mismatched ssDNA (5 μM). The obtained results demonstrate the potential of the MLAPS in combination with the simple and rapid LbL immobilization technique as a promising platform for the future development of multi-spot light-addressable label-free DNA chips with direct electrical readout.
Capacitive field-effect sensors modified with a multi-enzyme membrane have been applied for an electronic transduction of biochemical signals processed by enzyme-based AND-Reset and OR-Reset logic gates. The local pH change at the sensor surface induced by the enzymatic reaction was used for the activation of the Reset function for the first time.