Fachbereich Medizintechnik und Technomathematik
Refine
Year of publication
- 2024 (9)
- 2023 (23)
- 2022 (32)
- 2021 (38)
- 2020 (40)
- 2019 (52)
- 2018 (46)
- 2017 (45)
- 2016 (32)
- 2015 (43)
- 2014 (42)
- 2013 (49)
- 2012 (41)
- 2011 (69)
- 2010 (61)
- 2009 (76)
- 2008 (51)
- 2007 (48)
- 2006 (32)
- 2005 (40)
- 2004 (75)
- 2003 (39)
- 2002 (45)
- 2001 (49)
- 2000 (53)
- 1999 (31)
- 1998 (32)
- 1997 (29)
- 1996 (27)
- 1995 (18)
- 1994 (9)
- 1993 (18)
- 1992 (11)
- 1991 (11)
- 1990 (15)
- 1989 (17)
- 1988 (20)
- 1987 (19)
- 1986 (6)
- 1985 (8)
- 1984 (7)
- 1983 (5)
- 1982 (20)
- 1981 (15)
- 1980 (29)
- 1979 (20)
- 1978 (25)
- 1977 (13)
- 1976 (16)
- 1975 (12)
- 1974 (4)
- 1973 (2)
- 1972 (6)
- 1968 (2)
- 1967 (1)
Document Type
- Article (1578) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- CellDrum (3)
- Label-free detection (3)
- biosensors (3)
- hydrogen peroxide (3)
- shakedown analysis (3)
- Bacillus atrophaeus (2)
- Bauingenieurwesen (2)
- CAD (2)
- Capacitive field-effect sensor (2)
- Einspielanalyse (2)
- Empirical process (2)
- Field-effect sensor (2)
- Goodness-of-fit test (2)
- Independence test (2)
- Light-addressable potentiometric sensor (2)
- Lipopolysaccharide (2)
- Paired sample (2)
- Parametric bootstrap (2)
- Raman spectroscopy (2)
- Shakedown analysis (2)
- Stiffness (2)
- Traglastanalyse (2)
- capacitive field-effect sensors (2)
- carbonized rice husk (2)
- civil engineering (2)
- constructive alignment (2)
- damage (2)
- examination (2)
- field-effect sensor (2)
- frequency mixing magnetic detection (2)
- impedance spectroscopy (2)
- likelihood ratio test (2)
- limit analysis (2)
- locomotion (2)
- long-term retention (2)
- multimodal (2)
- muscle fascicle behavior (2)
- not identically distributed (2)
- practical learning (2)
- shakedown (2)
- tobacco mosaic virus (TMV) (2)
- ultrasound (2)
- ultrasound imaging (2)
- (Bio)degradation (1)
- Acceleration (1)
- Achilles tendon (1)
- Adaptive control (1)
- Afterload (1)
- Ageing (1)
- Air purification (1)
- AlterG (1)
- Alternating plasticity (1)
- Alzheimer's disease (1)
- Analysis (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Architectural design (1)
- Architectural gear ratio (1)
- Architektur (1)
- Arthosetherapie (1)
- Assistive technology (1)
- Asymptotic efficiency (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Automatic control (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Bacillus atrophaeus spores (1)
- Bacillus sp (1)
- Bacterial cellulose (1)
- Balance (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bicharakteristikenverfahren (1)
- Bioabsorbable (1)
- Biocomposites (1)
- Biomechanical simulation (1)
- Bioreaktor (1)
- Biosolubilization (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- Booster Station (1)
- Bootstrap (1)
- Bootstrapping (1)
- Brownian Pillow (1)
- CNOT (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Carbon sources (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Categorial variable (1)
- Cell permeability (1)
- Cellular force (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Cementoblast (1)
- Censored data (1)
- Chemical images (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Circular Dichroism (1)
- Clusterion (1)
- Co-managed care (1)
- Collective risk model (1)
- Competitiveness (1)
- Complex System (1)
- Complex-valued eigenvalues (1)
- Compliance (1)
- Compression (1)
- Computational biomechanics (1)
- Concomitant (1)
- Conductive Boundary Condition (1)
- Constitutive model (1)
- Contractile tension (1)
- Contractility (1)
- Convex optimization (1)
- Cost-effectiveness (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- Cramér-von-Mises test (1)
- Cross border adjustment mechanism (1)
- Crámer–von-Mises distance (1)
- Culture media (1)
- C–V method (1)
- DNA biosensor (1)
- DNA hybridization (1)
- DPA (dipicolinic acid) (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Deep Learning (1)
- Deformation (1)
- Dehydrogenase (1)
- Design-by-analysis (1)
- Diaphorase (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Discrete Optimization (1)
- Distorsion des oberen Sprunggelenks (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- Druckgeräte (1)
- Drug simulation (1)
- E-Mobility (1)
- EIS capacitive sensor (1)
- ELISA (1)
- ES-FEM (1)
- Eigenvalue trajectories (1)
- Einspiel-Analyse (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elderly (1)
- Electrolyte–insulator–semiconductor (1)
- Electromagnetism (1)
- Electromechanical modeling (1)
- Elektroenzephalographie (1)
- Elemental (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Energy-intensive industry (1)
- Enterprise information systems (1)
- Environmental impact (1)
- Enzymatic biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Equivalence test (1)
- Esophageal Doppler monitor (1)
- Experiment (1)
- External knee adduction moments (1)
- FS-FEM (1)
- Fall prevention (1)
- Fault approximation (1)
- Fault detection (1)
- Fehlerstellen (1)
- Fibroblast (1)
- Field effect (1)
- Field-effect biosensor (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Fließgrenze (1)
- Floor prices (1)
- Force (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Frequency mixing magnetic detection (1)
- Functional Delta Method (1)
- Fußball (1)
- Gamma distribution (1)
- Geriatric (1)
- German (1)
- Glaucoma (1)
- Global and local collapse (1)
- Gold nanoparticles (1)
- Gonarthrose (1)
- Goodness-of-fit tests for uniformity (1)
- Grenzwertberechnung (1)
- Ground-level falls (1)
- Hadamard differentiability (1)
- Haemodialysis (1)
- Handbike (1)
- Harnleiter (1)
- Heart tissue culture (1)
- Hemoglobin structure (1)
- Heterostructure (1)
- Hip fractures (1)
- Hodgkin–Huxley models (1)
- Hoeffding-Blum-Kiefer-Rosenblatt independence test (1)
- Homogenization (1)
- Hotelling’s T² test (1)
- Human-Computer interaction (1)
- Hydrogen peroxide (1)
- Hämoglobin (1)
- Hämoglobinstruktur (1)
- Image Reconstruction (1)
- Impedance spectroscopy (1)
- Incomplete data (1)
- Induced pluripotent stem cells (1)
- Information extraction (1)
- Inotropic compounds (1)
- Integrated empirical distribution (survival) function (1)
- Interior transmission problem (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse Scattering (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Inverse scattering problem (1)
- Ion channels (1)
- Iterative learning control (1)
- Kinetic energy (1)
- Kniegelenkarthrose (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Kohlenstofffaser (1)
- LPS (1)
- Lab-on-Chip (1)
- Langevin theory (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- Light-addressable Potentiometric Sensor (1)
- Limit analysis (1)
- Liver (1)
- Long COVID (1)
- Luftreiniger (1)
- MBST (1)
- MCDA (1)
- MOS (1)
- Machine learning (1)
- Magnetic nanoparticles (1)
- Manipulated variables (1)
- Marginal homogeneity test (1)
- Materialermüdung (1)
- Mechanotransduction (1)
- Medusomyces gisevi (1)
- Metascintillator (1)
- Microcirculation (1)
- Micromagnetic simulation (1)
- Mild cognitive impairment (1)
- Mobility (1)
- Mobility tests (1)
- Mobility transition (1)
- Model-driven software engineering (1)
- Multi-criteria decision analysis (1)
- Multi-sample problem (1)
- Multianalyte detection (1)
- Multicell (1)
- Multiple TOF kernels (1)
- Multiplexing (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NONOate (1)
- Natural fibres (1)
- Negative impedance convertor (1)
- Neural Network (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Non-parallel fissures (1)
- Nonequilibrium dynamics (1)
- Nonlinear Dynamics (1)
- Nucleus Pulposus (1)
- Numerical inversion of Laplace transforms (1)
- Numerical linear algebra (1)
- O2 plasma (1)
- Ocular blood flow (1)
- Organic light-emitting diode display (1)
- Organkultur (1)
- Osteoporose (1)
- Osteoporosis (1)
- Paralympic sport (1)
- Penicillin (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Pflanzenstress (1)
- Pharmacology (1)
- Physiology (1)
- Plant virus (1)
- Plasmacluster ion technology (1)
- Plastizität (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polylactide acid (1)
- Polymer-matrix composites (1)
- Post-COVID-19 syndrome (1)
- Preference assessment (1)
- Pressure loaded crack-face (1)
- Prevention (1)
- Product-integration (1)
- Progressive plastic deformation (1)
- Prophylaxis (1)
- Proximal humerus fracture (1)
- Psychiatrische Biomarker (1)
- Pulsations (1)
- Pump System (1)
- RVA (1)
- Ratchetting (1)
- Raumluft (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Red blood cell storage (1)
- Regionalization (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Resampling test (1)
- Resistive temperature detector (1)
- Resolvent Operator (1)
- Resonance-mode measurement (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Robotic rehabilitation (1)
- Rohr (1)
- Rohrbruch (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- ScaLAPACK (1)
- Schienbeinschoner (1)
- Schlafspindeldetektion (1)
- Schwammknochen (1)
- Semi-parametric random censorship model (1)
- Septic cardiomyopathy (1)
- Shakedown (1)
- Shakedown criterion (1)
- Silk fibroin (1)
- Simulation (1)
- Simultaneous determination (1)
- Skeletal muscle (1)
- Small Aral Sea (1)
- Sn₃O₄ (1)
- Software and systems modeling (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Stahl (1)
- Steel industry (1)
- Sterilisation process (1)
- Stress concentrations (1)
- Strukturanalyse (1)
- SunRav BookEditor (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Survival analysis (1)
- TMV adsorption (1)
- TOF PET (1)
- Ta₂O₅ gate (1)
- Technical Operations Research (TOR) (1)
- Temperaturabhängigkeit (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tendons (1)
- Tension (1)
- Tinetti test (1)
- Tissue Engineering (1)
- Tobacco mosaic virus (TMV) (1)
- Traglast (1)
- Transmission Eigenvalues (1)
- Ultrasound (1)
- Uniaxial compression test (1)
- Vapnik–Čhervonenkis class (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Velocity (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Visual field asymmetry (1)
- Volterra integral equation (1)
- Volume of confidence regions (1)
- Volume status (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Wundheilung (1)
- XOR (1)
- Zeta potential (1)
- Zug-Druck Belastung (1)
- acetoin (1)
- acetoin reductase (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- alcoholic beverages (1)
- allocation (1)
- alternierend Verformbarkeit (1)
- amperometric biosensors (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- annealing (1)
- aortic perfusion (1)
- architecture (1)
- aromatic amines (1)
- arthrosis therapy (1)
- artificial olfactory image (1)
- asymptotic relative efficiency (1)
- atomic layer deposition (1)
- barium strontium titanate (1)
- biaxial tensile experiment (1)
- bicharacteristics (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- biomechanics (1)
- biopotential electrodes (1)
- biosensor (1)
- bone density (1)
- bone structure (1)
- bootstrap (1)
- burst pressure (1)
- burst tests (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- cancellous bone (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capacitive field-effect sensor (1)
- carbon electrodes (1)
- cardiomyocyte biomechanics (1)
- catalytic metal (1)
- cell aerosolization (1)
- cell atomization (1)
- central symmetry test (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- chemical sensor (1)
- cognitive impairment (1)
- community dwelling (1)
- complete block symmetry (1)
- computational fluid dynamics analysis (1)
- conditional excess distribution (1)
- conditional expectation principle (1)
- confidence interval (1)
- connective tissue (1)
- constitutive modeling (1)
- contactless conductivity sensor (1)
- correlation (1)
- coupled Néel–Brownian relaxation dynamics (1)
- covariance principle (1)
- dental trauma (1)
- dialysis (1)
- difficult airway (1)
- direct method (1)
- distance learning (1)
- distorted element (1)
- double-lumen tube intubation (1)
- drop jump (1)
- e-books (1)
- e-issues (1)
- ecological structure (1)
- eigensolvers (1)
- elastic solids (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electromyography (1)
- electronic nose (1)
- encapsulation materials (1)
- endoluminal (1)
- endospores (1)
- energy absorption (1)
- energy dissipation (1)
- enzymatic (bio)degradation (1)
- enzymatic biosensor (1)
- enzyme cascade (1)
- epithelization (1)
- exchangeability test (1)
- extracorporeal membrane oxygenation (1)
- fatigue analyses (1)
- fibroin (1)
- fibulare Bandruptur (1)
- field-effect structure (1)
- flaw (1)
- force generation (1)
- forecast (1)
- forehead EEG (1)
- fortschreitende plastische Deformation (1)
- frequency mixing (1)
- functional data (1)
- gait (1)
- gas sensor (1)
- glucose (1)
- glucose oxidase (GOx) (1)
- gonarthrosis (1)
- goodness-of-fit test (1)
- graphene oxide (1)
- healthy aging (1)
- heavy metals (1)
- hiPS cardiomyocytes (1)
- high-intensity exercise (1)
- high-k material (1)
- horseradish peroxidase (HRP) (1)
- huge dimensional data (1)
- human dermal fibroblasts (1)
- humic acid (1)
- hydroxylation (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- immobilization (1)
- in-ear EEG (1)
- in-situ monitoring (1)
- independence test (1)
- intraclass correlation coefficient (1)
- key performance indicators (1)
- konvexe Optimierung (1)
- lable-free detection (1)
- large language models (1)
- layer-by-layer technique (1)
- light-addressable potentiometric sensor (1)
- light-addressing technologies (1)
- lignite (1)
- limit load (1)
- lipopolysaccharide (1)
- lipopolysaccharides (1)
- load limit (1)
- magnetic actuation (1)
- magnetic beads (1)
- magnetic biosensing (1)
- magnetic nanoparticles (1)
- magnetic relaxation (1)
- magnetic sandwich immunoassay (1)
- magnetic sensing (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- mechanical buffer (1)
- metagenomics (1)
- metal-oxide-semiconductor structure (1)
- microbial diversity (1)
- micromagnetic simulation (1)
- multi-functional material (1)
- multinomial distribution (1)
- multiparametric immunoassays (1)
- multivariate normal distribution (1)
- muscle mechanics (1)
- nanobelts (1)
- nanomaterials (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- naphtols (1)
- non-simplex S-FEM elements (1)
- novel photoexcitation method (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organosilanes (1)
- overload (1)
- pH sensors (1)
- parabolic flight (1)
- penicillin (1)
- penicillinase (1)
- performance analysis (1)
- performance testing (1)
- phenols (1)
- photoelectrochemistry (1)
- physiology (1)
- pipes (1)
- plant scanner (1)
- plant stress (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- poly(d, l-lactic acid) (1)
- polyaniline (1)
- portfolio risk (1)
- prevention (1)
- psychosocial (1)
- random effects (1)
- random effects meta-regression model (1)
- ratchetting (1)
- rehabilitation (1)
- reliability analysis (1)
- reliability of structures (1)
- retinal microvasculature (1)
- retinal vessels (1)
- running (1)
- rupture of the fibular ligament (1)
- sEMG (1)
- sarcomere operating length (1)
- scanned light pulse technique (1)
- semantic role labeling (1)
- separable Hilbert space (1)
- series elastic element behavior (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- shoulder (1)
- silanization (1)
- simulation (1)
- smooth muscle contraction (1)
- softs (1)
- spatial resolution (1)
- speaker attribution (1)
- sprint start (1)
- standard error of measurement (1)
- sterilisation (1)
- sterility tests (1)
- sterilization (1)
- sterilization conditions (1)
- sterilization efficacy (1)
- sterilization methods (1)
- stiffness (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- superparamagnetic bead (1)
- superparamagnetic nanoparticles (1)
- surface functionalization (1)
- surface modification (1)
- survival (1)
- temperature (1)
- tendon rupture (1)
- tension–torsion loading (1)
- test-retest reliability (1)
- thermal ratcheting (1)
- tilted constant illumination (1)
- titanium dioxide photoanode (1)
- tri-lineage differentiation (1)
- turnip vein clearing virus (TVCV) (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- ultrathin gate insulators (1)
- uniformly most powerful invariant test (1)
- unloading (1)
- validation methods (1)
- vessels (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- visualization (1)
- walking (1)
- walking gait (1)
- wound healing (1)
- yield stress (1)
- · Psychiatrische Erkrankungen/Diagnostik (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1578)
- INB - Institut für Nano- und Biotechnologien (461)
- IfB - Institut für Bioengineering (366)
- Fachbereich Chemie und Biotechnologie (31)
- Fachbereich Energietechnik (3)
- Nowum-Energy (3)
- Institut fuer Angewandte Polymerchemie (2)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- Fachbereich Luft- und Raumfahrttechnik (1)
During rapid deceleration of the body, tendons buffer part of the elongation of the muscle-tendon unit (MTU), enabling safe energy dissipation via eccentric muscle contraction. Yet, the influence of changes in tendon stiffness within the physiological range upon these lengthening contractions is unknown. This study aimed to examine the effect of training-induced stiffening of the Achilles tendon on triceps surae muscle-tendon behavior during a landing task. Twenty-one male subjects were assigned to either a 10-week resistance-training program consisting of single-leg isometric plantarflexion (n = 11) or to a non-training control group (n = 10). Before and after the training period, plantarflexion force, peak Achilles tendon strain and stiffness were measured during isometric contractions, using a combination of dynamometry, ultrasound and kinematics data. Additionally, testing included a step-landing task, during which joint mechanics and lengths of gastrocnemius and soleus fascicles, Achilles tendon, and MTU were determined using synchronized ultrasound, kinematics and kinetics data collection. After training, plantarflexion strength and Achilles tendon stiffness increased (15 and 18%, respectively), and tendon strain during landing remained similar. Likewise, lengthening and negative work produced by the gastrocnemius MTU did not change detectably. However, in the training group, gastrocnemius fascicle length was offset (8%) to a longer length at touch down and, surprisingly, fascicle lengthening and velocity were reduced by 27 and 21%, respectively. These changes were not observed for soleus fascicles when accounting for variation in task execution between tests. These results indicate that a training-induced increase in tendon stiffness does not noticeably affect the buffering action of the tendon when the MTU is rapidly stretched. Reductions in gastrocnemius fascicle lengthening and lengthening velocity during landing occurred independently from tendon strain. Future studies are required to provide insight into the mechanisms underpinning these observations and their influence on energy dissipation.
Comparison of different training algorithms for the leg extension training with an industrial robot
(2018)
In the past, different training scenarios have been developed and implemented on robotic research platforms, but no systematic analysis and comparison have been done so far. This paper deals with the comparison of an isokinematic (motion with constant velocity) and an isotonic (motion against constant weight) training algorithm. Both algorithms are designed for a robotic research platform consisting of a 3D force plate and a high payload industrial robot, which allows leg extension training with arbitrary six-dimensional motion trajectories. In the isokinematic as well as the isotonic training algorithm, individual paths are defined i n C artesian s pace by sufficient s upport p oses. I n t he i sotonic t raining s cenario, the trajectory is adapted to the measured force as the robot should only move along the trajectory as long as the force applied by the user exceeds a minimum threshold. In the isotonic training scenario however, the robot’s acceleration is a function of the force applied by the user. To validate these findings, a simulative experiment with a simple linear trajectory is performed. For this purpose, the same force path is applied in both training scenarios. The results illustrate that the algorithms differ in the force dependent trajectory adaption.
Training-induced increase in Achilles tendon stiffness affects tendon strain pattern during running
(2019)
Background
During the stance phase of running, the elasticity of the Achilles tendon enables the utilisation of elastic energy and allows beneficial contractile conditions for the triceps surae muscles. However, the effect of changes in tendon mechanical properties induced by chronic loading is still poorly understood. We tested the hypothesis that a training-induced increase in Achilles tendon stiffness would result in reduced tendon strain during the stance phase of running, which would reduce fascicle strains in the triceps surae muscles, particularly in the mono-articular soleus.
Methods
Eleven subjects were assigned to a training group performing isometric singleleg plantarflexion contractions three times per week for ten weeks, and another ten subjects formed a control group. Before and after the training period, Achilles tendon stiffness was estimated, and muscle-tendon mechanics were assessed during running at preferred speed using ultrasonography, kinematics and kinetics.
Results
Achilles tendon stiffness increased by 18% (P <0:01) in the training group, but the associated reduction in strain seen during isometric contractions was not statistically significant. Tendon elongation during the stance phase of running was similar after training, but tendon recoil was reduced by 30% (P <0:01), while estimated tendon force remained unchanged. Neither gastrocnemius medialis nor soleus fascicle shortening during stance was affected by training.
Discussion
These results show that a training-induced increase in Achilles tendon
stiffness altered tendon behaviour during running. Despite training-induced changes in tendon mechanical properties and recoil behaviour, the data suggest that fascicle shortening patterns were preserved for the running speed that we examined. The asymmetrical changes in tendon strain patterns supports the notion that simple inseries models do not fully explain the mechanical output of the muscle-tendon unit during a complex task like running.
Neuromuscular strength training of the leg extensor muscles plays an important role in the rehabilitation and prevention of age and wealth related diseases. In this paper, we focus on the design and implementation of a Cartesian admittance control scheme for isotonic training, i.e. leg extension and flexion against a predefined weight. For preliminary testing and validation of the designed algorithm an experimental research and development platform consisting of an
industrial robot and a force plate mounted at its end-effector has been used. Linear, diagonal and arbitrary two-dimensional motion trajectories with different weights for the leg extension and flexion part are applied. The proposed algorithm is easily adaptable to trajectories consisting of arbitrary six-dimensional poses and allows the implementation of individualized trajectories.
To prevent the reduction of muscle mass and loss of strength coming along with the human aging process, regular training with e.g. a leg press is suitable. However, the risk of training-induced injuries requires the continuous monitoring and controlling of the forces applied to the musculoskeletal system as well as the velocity along the motion trajectory and the range of motion. In this paper, an adaptive norm-optimal iterative learning control algorithm to minimize the knee joint loadings during the leg extension training with an industrial robot is proposed. The response of the algorithm is tested in simulation for patients with varus, normal and valgus alignment of the knee and compared to the results of a higher-order iterative learning control algorithm, a robust iterative learning control and a recently proposed conventional norm-optimal iterative learning control algorithm. Although significant improvements in performance are made compared to the conventional norm-optimal iterative learning control algorithm with a small learning factor, for the developed approach as well as the robust iterative learning control algorithm small steady state errors occur.
Achilles tendon rupture (ATR) patients have persistent functional deficits in the triceps surae muscle–tendon unit (MTU). The complex remodeling of the MTU accompanying these deficits remains poorly understood. The purpose of the present study was to associate in vivo and in silico data to investigate the relations between changes inMTU properties and strength deficits inATR patients. Methods: Elevenmale subjects who had undergone surgical repair of complete unilateral ATR were examined 4.6 ± 2.0 (mean ± SD) yr after rupture. Gastrocnemius medialis (GM) tendon stiffness, morphology, and muscle architecture were determined using ultrasonography. The force–length relation of the plantar flexor muscles was assessed at five ankle joint angles. In addition, simulations (OpenSim) of the GM MTU force–length properties were performed with various iterations of MTU properties found between the unaffected and the affected side. Results: The affected side of the patients displayed a longer, larger, and stiffer GM tendon (13% ± 10%, 105% ± 28%, and 54% ± 24%, respectively) compared with the unaffected side. The GM muscle fascicles of the affected side were shorter (32% ± 12%) and with greater pennation angles (31% ± 26%). A mean deficit in plantarflexion moment of 31% ± 10% was measured. Simulations indicate that pairing an intact muscle with a longer tendon shifts the optimal angular range of peak force outside physiological angular ranges, whereas the shorter muscle fascicles and tendon stiffening seen in the affected side decrease this shift, albeit incompletely. Conclusions: These results suggest that the substantial changes in MTU properties found in ATR patients may partly result from compensatory remodeling, although this process appears insufficient to fully restore muscle function.
Performing tasks, such as running and jumping, requires activation of the agonist and antagonist muscles before (motor unit pre-activation) and during movement performance (Santello and Mcdonagh, 1998). A well-timed and regulated muscle activation elicits a stretch-shortening cycle (SSC) response, naturally occurring in bouncing movements (Ishikawa and Komi, 2004; Taube et al., 2012). By definition, the SSC describes the stretching of a pre-activated muscle-tendon complex immediately followed by a muscle shortening in the concentric push-off phase (Komi, 1984).
Given the importance of SSC actions for human movement, it is not surprising that many studies investigated the biomechanics of this phenomenon; in particular, drop jumps (DJs) represent a good paradigm to study muscle fascicle and tendon behavior in ballistic movements involving the SSC.
Within a DJ, three main phases [pre-activation, braking, and push-off (PO; Komi, 2000)] have been recognized and extensively studied in common and challenging conditions, such as changes in load, falling height, or simulated hypo-gravity (Avela et al., 1994; Arampatzis et al., 2001; Fukashiro et al., 2005; Ishikawa et al., 2005; Sousa et al., 2007; Ritzmann et al., 2016; Helm et al., 2020).
These studies show that the timing and amount of triceps-surae muscle-tendon unit pre-activation in DJs are differentially regulated based on the load applied to the muscle, being optimal in normal “Earth” gravity conditions (Avela et al., 1994), but decreased in simulated hypo-gravity, hyper-gravity (Avela et al., 1994; Ritzmann et al., 2016), or unknown conditions (i.e., unknown falling heights; Helm et al., 2020). Some authors indicated that, when falling from heights different from the optimal one [defined as the drop height giving a maximum DJ performance indicated as peak ground reaction force (GRF) or jump high], electromyographic (EMG) activity of the plantar flexors increases from lower than optimal to higher than optimal heights (Ishikawa and Komi, 2004; Sousa et al., 2007).
These findings highlight the ability of the central nervous system to regulate the timing and amount of pre-activation according to different jumping conditions, thus regulating muscle fascicle length, tendon and joint stiffness as well as position, in order to safely land on the ground and quickly re-bounce.
Similarly, to pre-activation, also in the braking phase, the plantar flexors are differentially regulated. In optimal height (i.e., load) jumping conditions, gastrocnemius medialis (GM) fascicles shorten at early ground contact (possibly due to the intervention of the stretch reflex; Gollhofer et al., 1992) and behave quasi-isometrically in the late braking phase, enabling tendon elongation, and storage of elastic energy (Gollhofer et al., 1992; Fukashiro et al., 2005; Sousa et al., 2007). When increasing the falling height (augmenting the impact GRF), the quasi-isometric behavior of fascicles disappears, and fast fascicle lengthening occurs (Ishikawa et al., 2005; Sousa et al., 2007).
In the third and last PO phase, fascicles shorten and the tendon releases the elastic energy previously stored. Bobbert et al. (1987) reported no influence of jumping height on the work done and on the net vertical impulse assessed during PO; this observation suggests that, despite an optimal DJ performance might be achieved only in specific conditions (falling heights, loads), the central nervous system seems to be able to regulate muscle behavior in order to effectively perform the required task also in challenging situations.
Although the regulation of triceps-surae muscle-tendon unit in DJs has been extensively investigated, very few studies focused on sarcomeres behavior during the performance of this SSC movement (Kurokawa et al., 2003; Fukashiro et al., 2005, 2006). Sarcomeres represent muscle contractile units and are known to express different amounts of force depending on their length (Gordon et al., 1966; Walker and Schrodt, 1974); thus, understanding the time course of their responses during DJs is fundamental to gain further insights into muscle force-generating capacity. In vivo measurement of sarcomere length in humans has been so far been performed only in static positions and under highly controlled experimental conditions (Llewellyn et al., 2008; Sanchez et al., 2015). Instead, human sarcomere length estimation (achieved by dividing GM measured fascicle length for a fixed sarcomere number) in dynamic contractions provided an indirect measure of sarcomere operating range during squat jump, countermovement jump, and DJ (Fukashiro et al., 2005, 2006; Kurokawa et al., 2003). The results of these studies showed that sarcomeres operate in the ascending limb of their length-tension (L-T) relationship in all types of jumps, and particularly so in DJ.
However, most of the available observations on sarcomere and muscle fascicle behavior were made in condition of constant gravity. Thus, in order to understand how sarcomere and muscle fascicle length are regulated in variable gravity conditions, we performed experiments in a parabolic flight, involving variable gravity levels, ranging from about zero-g to about double the Earth’s gravity (1 g; Waldvogel et al., 2021).
Specifically, the aims of the present study were as follows:
1. To investigate the ability of the neuromuscular system in regulating fascicle length in response to conditions of variable gravity.
2. To estimate sarcomere operative length in the different DJ phases, in order to calculate its theoretical force production and its possible modulation in conditions of variable gravity.
We hypothesized that muscle fascicles would be differentially regulated in different gravity conditions compared to 1 g, particularly in anticipation of landing and re-bouncing in unknown gravity levels. In addition, we hypothesized that sarcomeres would operate in the upper part of the ascending limb of their L-T relationship, possibly lengthening during the braking phase (especially in hyper-gravity) while operating quasi-isometrically in 1 g.
The compliant nature of distal limb muscle-tendon units is traditionally considered suboptimal in explosive movements when positive joint work is required. However, during accelerative running, ankle joint net mechanical work is positive. Therefore, this study aims to investigate how plantar flexor muscle-tendon behavior is modulated during fast accelerations. Eleven female sprinters performed maximum sprint accelerations from starting blocks, while gastrocnemius muscle fascicle lengths were estimated using ultrasonography. We combined motion analysis and ground reaction force measurements to assess lower limb joint kinematics and kinetics, and to estimate gastrocnemius muscle-tendon unit length during the first two acceleration steps. Outcome variables were resampled to the stance phase and averaged across three to five trials. Relevant scalars were extracted and analyzed using one-sample and two-sample t-tests, and vector trajectories were compared using statistical parametric mapping. We found that an uncoupling of muscle fascicle behavior from muscle-tendon unit behavior is effectively used to produce net positive mechanical work at the joint during maximum sprint acceleration. Muscle fascicles shortened throughout the first and second steps, while shortening occurred earlier during the first step, where negative joint work was lower compared with the second step. Elastic strain energy may be stored during dorsiflexion after touchdown since fascicles did not lengthen at the same time to dissipate energy. Thus, net positive work generation is accommodated by the reuse of elastic strain energy along with positive gastrocnemius fascicle work. Our results show a mechanism of how muscles with high in-series compliance can contribute to net positive joint work.
The international partnership of space agencies has agreed to proceed forward to the Moon sustainably. Activities on the Lunar surface (0.16 g) will allow crewmembers to advance the exploration skills needed when expanding human presence to Mars (0.38 g). Whilst data from actual hypogravity activities are limited to the Apollo missions, simulation studies have indicated that ground reaction forces, mechanical work, muscle activation, and joint angles decrease with declining gravity level. However, these alterations in locomotion biomechanics do not necessarily scale to the gravity level, the reduction in gastrocnemius medialis activation even appears to level off around 0.2 g, while muscle activation pattern remains similar. Thus, it is difficult to predict whether gastrocnemius medialis contractile behavior during running on Moon will basically be the same as on Mars. Therefore, this study investigated lower limb joint kinematics and gastrocnemius medialis behavior during running at 1 g, simulated Martian gravity, and simulated Lunar gravity on the vertical treadmill facility. The results indicate that hypogravity-induced alterations in joint kinematics and contractile behavior still persist between simulated running on the Moon and Mars. This contrasts with the concept of a ceiling effect and should be carefully considered when evaluating exercise prescriptions and the transferability of locomotion practiced in Lunar gravity to Martian gravity.