INB - Institut für Nano- und Biotechnologien
Refine
Year of publication
Document Type
- Article (451) (remove)
Has Fulltext
- no (451) (remove)
Keywords
- LAPS (3)
- capacitive field-effect sensor (3)
- field-effect sensor (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Light-addressable potentiometric sensor (2)
- Raman spectroscopy (2)
- gold nanoparticles (2)
- hydrogen peroxide (2)
- light-addressable potentiometric sensor (2)
- (Bio)degradation (1)
- Bacillus atrophaeus spores (1)
- CNOT (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Chemical images (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- C–V method (1)
- DNA biosensor (1)
- DPA (dipicolinic acid) (1)
- Dehydrogenase (1)
- Diaphorase (1)
- EIS capacitive sensor (1)
- Electrolyte–insulator–semiconductor (1)
- Enzymatic biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Field effect (1)
- Field-effect biosensor (1)
- Field-effect sensor (1)
- Hydrogen peroxide (1)
- Impedance spectroscopy (1)
- Label-free detection (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- MOS (1)
- Multianalyte detection (1)
- Negative impedance convertor (1)
- O2 plasma (1)
- Organic light-emitting diode display (1)
- Penicillin (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Real-time monitoring (1)
- Resonance-mode measurement (1)
- Simultaneous determination (1)
- Sn₃O₄ (1)
- Sterilisation process (1)
- TMV adsorption (1)
- Ta₂O₅ gate (1)
- XOR (1)
- actuator-sensor system (1)
- aminooctanethiol (1)
- annealing (1)
- artificial olfactory image (1)
- aseptic parameters (1)
- bi-enzyme biosensor (1)
- biosensor (1)
- biosensors (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive EIS sensor (1)
- capacitive model (1)
- catalytic metal (1)
- chemical sensor (1)
- control gate (1)
- detection of charged macromolecules (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electrolyte-insulator-semiconductor capacitors (1)
- electronic nose (1)
- endospores (1)
- enzyme cascade (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- equivalent circuit (1)
- field-effect structure (1)
- gas sensor (1)
- gaseous hydrogen peroxide (1)
- glucose oxidase (GOx) (1)
- heavy metals (1)
- horseradish peroxidase (HRP) (1)
- hydroxylation (1)
- immobilization (1)
- light-addressable electrode (1)
- light-addressing technologies (1)
- metal-oxide-semiconductor structure (1)
- microfluidics (1)
- multi-sensing platform (1)
- multianalyte detection (1)
- nanobelts (1)
- nanoparticle coverage (1)
- on-chip integrated addressable EISCAP sensors (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organosilanes (1)
- penicillinase (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- polystyrene sulfonate (1)
- scanned light pulse technique (1)
- silanization (1)
- spore kill rate (1)
- sterilisation (1)
- sterility (1)
- sterilization (1)
- sterilization conditions (1)
- surface functionalization (1)
- temperature (1)
- turnip vein clearing virus (TVCV) (1)
- urease (1)
- visualization (1)
Institute
- INB - Institut für Nano- und Biotechnologien (451) (remove)
Microfabrication, characterization and analytical application of a new thin-film silver microsensor
(2009)
Sensing charged macromolecules with nanocrystalline diamond-based field-effect capacitive sensors
(2008)
Optoelectronic Properties of Nanostructured Ensembles Controlled by Biomolecular Logic Systems
(2008)
Markierungsfreie DNA-Detektion mit Silizium-Feldeffekt-Sensoren – Messeffekte oder Artefakte?
(2007)
Handheld measurement device for field-effect sensor structures: Practical evaluation and limitations
(2007)
Light-addressable potentiometric sensors (LAPS) are field-effect-based sensors. A modulated light source is used to define the particular measurement spot to perform spatially resolved measurements of chemical species and to generate chemical images. In this work, an organic-LED (OLED) display has been chosen as a light source. This allows high measurement resolution and miniaturisation of the system. A new developed driving method for the OLED display optimised for LAPS-based measurements is demonstrated. The new method enables to define modulation frequencies between 1 kHz and 16 kHz and hence, reduces the measurement time of a chemical image by a factor of 40 compared to the traditional addressing of an OLED display.
Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS?
(2000)
The hybrid K+/Ca2+ sensor based on laser scanned silicon transducer for multi-component analysis
(2002)