Elsevier
Refine
Year of publication
Document Type
- Article (321)
- Part of a Book (12)
- Conference Proceeding (9)
- Other (1)
Keywords
- Earthquake (4)
- LAPS (4)
- Gamification (3)
- Heparin (3)
- Central receiver power plant (2)
- Central receiver system (2)
- Chemometrics (2)
- Concentrated solar collector (2)
- Concentrated systems (2)
- Field-effect sensor (2)
- Gas turbine (2)
- IR spectroscopy (2)
- Light-addressable potentiometric sensor (2)
- NMR spectroscopy (2)
- Solar concentration (2)
- Standardization (2)
- hydrogen peroxide (2)
- qNMR (2)
- (Bio)degradation (1)
- (Poly)saccharides (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (181)
- INB - Institut für Nano- und Biotechnologien (105)
- IfB - Institut für Bioengineering (64)
- Fachbereich Chemie und Biotechnologie (56)
- Fachbereich Luft- und Raumfahrttechnik (33)
- Fachbereich Energietechnik (29)
- Fachbereich Maschinenbau und Mechatronik (16)
- Fachbereich Bauingenieurwesen (14)
- Solar-Institut Jülich (14)
- Fachbereich Elektrotechnik und Informationstechnik (7)
- Nowum-Energy (5)
- Fachbereich Wirtschaftswissenschaften (4)
- Institut fuer Angewandte Polymerchemie (4)
- ECSM European Center for Sustainable Mobility (3)
- Kommission für Forschung und Entwicklung (3)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (3)
- Sonstiges (3)
- Fachbereich Architektur (1)
- Freshman Institute (1)
It is well known that the already large dielectric constants of some electrolytes like BaTiO₃ can be enhanced further by adding metallic (e.g. Ni, Cu or Ag) nanoparticles. The enhancement can be quite large, a factor of more than 1000 is possible. The consequences for the properties will be discussed in the present paper applying a brick-layer model (BLM) for calculating dc-resistivities of thin layers and a modified one (PBLM) that includes percolation for calculating dielectric properties of these materials. The PBLM results in an at least qualitative description and understanding of the physical phenomena: This model gives an explanation for the steep increase of the dielectric constant below the percolation threshold and why this increase is connected to a dramatic decrease of the breakdown voltage as well as the ability of storing electrical energy. We conclude that metallic electrolyte composites like BaTiO₃ are not appropriate for energy storage.
A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.