Elsevier
Refine
Year of publication
Document Type
- Article (321)
- Part of a Book (12)
- Conference Proceeding (9)
- Other (1)
Keywords
- Earthquake (4)
- LAPS (4)
- Gamification (3)
- Heparin (3)
- Central receiver power plant (2)
- Central receiver system (2)
- Chemometrics (2)
- Concentrated solar collector (2)
- Concentrated systems (2)
- Field-effect sensor (2)
- Gas turbine (2)
- IR spectroscopy (2)
- Light-addressable potentiometric sensor (2)
- NMR spectroscopy (2)
- Solar concentration (2)
- Standardization (2)
- hydrogen peroxide (2)
- qNMR (2)
- (Bio)degradation (1)
- (Poly)saccharides (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (181)
- INB - Institut für Nano- und Biotechnologien (105)
- IfB - Institut für Bioengineering (64)
- Fachbereich Chemie und Biotechnologie (56)
- Fachbereich Luft- und Raumfahrttechnik (33)
- Fachbereich Energietechnik (29)
- Fachbereich Maschinenbau und Mechatronik (16)
- Fachbereich Bauingenieurwesen (14)
- Solar-Institut Jülich (14)
- Fachbereich Elektrotechnik und Informationstechnik (7)
- Nowum-Energy (5)
- Fachbereich Wirtschaftswissenschaften (4)
- Institut fuer Angewandte Polymerchemie (4)
- ECSM European Center for Sustainable Mobility (3)
- Kommission für Forschung und Entwicklung (3)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (3)
- Sonstiges (3)
- Fachbereich Architektur (1)
- Freshman Institute (1)
It is well known that the already large dielectric constants of some electrolytes like BaTiO₃ can be enhanced further by adding metallic (e.g. Ni, Cu or Ag) nanoparticles. The enhancement can be quite large, a factor of more than 1000 is possible. The consequences for the properties will be discussed in the present paper applying a brick-layer model (BLM) for calculating dc-resistivities of thin layers and a modified one (PBLM) that includes percolation for calculating dielectric properties of these materials. The PBLM results in an at least qualitative description and understanding of the physical phenomena: This model gives an explanation for the steep increase of the dielectric constant below the percolation threshold and why this increase is connected to a dramatic decrease of the breakdown voltage as well as the ability of storing electrical energy. We conclude that metallic electrolyte composites like BaTiO₃ are not appropriate for energy storage.
A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.
One-chip integrated dual amperometric/field-effect sensor for the detection of dissolved hydrogen
(2011)
A light-addressable potentiometric sensor (LAPS) can measure the concentration of one or several analytes at the sensor surface simultaneously in a spatially resolved manner. A modulated light pointer stimulates the semiconductor structure at the area of interest and a responding photocurrent can be read out. By simultaneous stimulation of several areas with light pointers of different modulation frequencies, the read out can be performed at the same time. With the new proposed controller electronic based on a field-programmable gate array (FPGA), it is possible to control the modulation frequencies, phase shifts, and light brightness of multiple light pointers independently and simultaneously. Thus, it is possible to investigate the frequency response of the sensor, and to examine the analyte concentration by the determination of the surface potential with the help of current/voltage curves and phase/voltage curves. Additionally, the ability to individually change the light intensities of each light pointer is used to perform signal correction.
Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface.
Upper and lower bound theorems of limit analyses have been presented in part I of the paper. Part II starts with the finite element discretization of these theorems and demonstrates how both can be combined in a primal–dual optimization problem. This recently proposed numerical method is used to guide the development of a new class of closed-form limit loads for circumferential defects, which show that only large defects contribute to plastic collapse with a rapid loss of strength with increasing crack sizes. The formulae are compared with primal–dual FEM limit analyses and with burst tests. Even closer predictions are obtained with iterative limit load solutions for the von Mises yield function and for the Tresca yield function. Pressure loading of the faces of interior cracks in thick pipes reduces the collapse load of circumferential defects more than for axial flaws. Axial defects have been treated in part I of the paper.
A new solar desalination system with heat recovery for decentralised drinking water production
(2009)
468 Scatter dose determination at the eye lens during a mask based whole brain radiotherapy (WBRT)
(2005)
It has been observed that carcinogenic polycyclic aromatic hydrocarbons (PAH) are present in the atmosphere. Combustion processes are considered the most important sources for PAH. Among these, the burning of coal produces the highest emission, but in cities with high traffic density and low meteorological exchange activities, vehicle emissions determine the immission situation, especially in narrow streets. For estimating the potential health effects caused by PAH, it is sufficient to characterize the emission of PAH with respect to their physical state, concentrations, and, as far as the particulate phase is concerned, size distribution. The size distribution is important for transport phenomena, inhalation, and deposition in the respiratory tract. These parameters mainly depend on the combustion system, on system operating conditions, on the exhaust system, and on exhaust cooling conditions. At exhaust-gas temperatures in the range of ambient air temperatures, almost the whole emission of PAH is made up of particulate matter.
Photoabsorption of alloys of Al with transition metals V, Fe, Ni and Cu and Pr near the Al L₂,₃-edge
(1974)
The onset of Al 2p transitions of VAl₃, FeAl, NiAl, NiAl₃, CuAl₂, PrAl₂ and the disordered alloys V-Al (16 at % Al, 28%, 41%), Fe-Al (11%) is shifted up to 1.1 eV. New pronounced structure develops close to the onset which for NiAl agrees with a density of states calculation by Connolly and Johnson.
The isotopes ¹³⁰,¹³²,¹³⁴,¹³⁶ Ce are investigated by means of the reactions ¹¹⁸,¹²⁰,¹²²,¹²⁴ Sn(¹⁶O, 4n) at bombarding energies between 68 and 76 MeV. From lifetime measurements a reduction of the collective behaviour is observed with increasing neutron number. Yrast cascades of rotational structure are identified up to angular momenta I=16⁺ or I=18⁺ in ¹³⁰,¹³²,¹³⁴ Ce. These cascades show a strong “back-bending” effect. In ¹³⁶ Ce no such simple yrast cascade could be found.
Yrast states up to spin 18 have been identified in ¹³²Ce. The energies and spins of the levels suggest the existence of two fairly well-behaved collective bands. The results are compared with those obtained in the rare-earth deformed region.