De Gruyter
Refine
Year of publication
Document Type
- Article (25)
- Part of a Book (10)
Keywords
- robotic process automation (2)
- Rehabilitation Technology and Prosthetics (1)
- Robotic process automation (1)
- Surgical Navigation and Robotics (1)
- applications (1)
- artificial intelligence (1)
- business process automation (1)
- commercial offthe- shelf solutions (1)
- constructive alignment (1)
- culpability (1)
- examination (1)
- liability (1)
- long-term retention (1)
- management (1)
- multimodal (1)
- practical learning (1)
- research framework (1)
- software evaluation (1)
- software selection (1)
- technology (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (14)
- IfB - Institut für Bioengineering (10)
- Fachbereich Architektur (6)
- Fachbereich Wirtschaftswissenschaften (4)
- Fachbereich Chemie und Biotechnologie (3)
- Fachbereich Elektrotechnik und Informationstechnik (3)
- Fachbereich Energietechnik (2)
- Fachbereich Bauingenieurwesen (1)
- Fachbereich Luft- und Raumfahrttechnik (1)
- Fachbereich Maschinenbau und Mechatronik (1)
- INB - Institut für Nano- und Biotechnologien (1)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (1)
The benefits of robotic process automation (RPA) are highly related to the usage of commercial off-the-shelf (COTS) software products that can be easily implemented and customized by business units. But, how to find the best fitting RPA product for a specific situation that creates the expected benefits? This question is related to the general area of software evaluation and selection. In the face of more than 75 RPA products currently on the market, guidance considering those specifics is required. Therefore, this chapter proposes a criteria-based selection method specifically for RPA. The method includes a quantitative evaluation of costs and benefits as well as a qualitative utility analysis based on functional criteria. By using the visualization of financial implications (VOFI) method, an application-oriented structure is provided that opposes the total cost of ownership to the time savings times salary (TSTS). For the utility analysis a detailed list of functional criteria for RPA is offered. The whole method is based on a multi-vocal review of scientific and non-scholarly literature including publications by business practitioners, consultants, and vendors. The application of the method is illustrated by a concrete RPA example. The illustrated
structures, templates, and criteria can be directly utilized by practitioners in their real-life RPA implementations. In addition, a normative decision process for selecting RPA alternatives is proposed before the chapter closes with a discussion and outlook.
Particularly multiparous elderly women may suffer from vaginal vault prolapse after hysterectomy due to weak support from lax apical ligaments. A decreased amount of estrogen and progesterone in older age is assumed to remodel the collagen thereby reducing tissue stiffness. Sacrocolpopexy is either performed as open or laparoscopic surgery using prosthetic mesh implants to substitute lax ligaments. Y-shaped mesh models (DynaMesh, Gynemesh, and Ultrapro) are implanted in a 3D female pelvic floor finite element model in the extraperitoneal space from the vaginal cuff to the first sacral (S1) bone below promontory. Numerical simulations are conducted during Valsalva maneuver with weakened tissues modeled by reduced tissue stiffness. Tissues are modeled as incompressible, isotropic hyperelastic materials whereas the meshes are modeled either as orthotropic linear elastic or as isotropic hyperlastic materials. The positions of the vaginal cuff and the bladder base are calculated from the pubococcygeal line for female pelvic floor at rest, for prolapse and after repair using the three meshes. Due to mesh mechanics and mesh pore deformation along the loaded direction, the DynaMesh with regular rectangular mesh pores is found to provide better mechanical support to the organs than the Gynemesh and the Ultrapro with irregular hexagonal mesh pores.
Insbesondere ältere, mehrgebährende Frauen leiden häufiger an einem Scheidenvorfall nach einer Hysterektomie aufgrund der schwachen Unterstützung durch laxe apikale Bänder. Es wird angenommen, dass eine verringerte Menge an Östrogen und Progesteron im höheren Alter das Kollagen umformt, wodurch die Gewebesteifigkeit reduziert wird. Die Sakrokolpopexie ist eine offene oder laparoskopische Operation, die mit prothetischen Netzimplantaten durchgeführt wird, um laxe Bänder zu ersetzen. Y-förmige Netzmodelle (DynaMesh, Gynemesh und Ultrapro) werden in einem 3D-Modell des weiblichen Beckenbodens im extraperitonealen Raum vom Vaginalstumpf bis zum Promontorium implantiert. Numerische Simulationen werden während des Valsalva-Manövers mit geschwächtem Gewebe durchgeführt, das durch eine reduzierte Gewebesteifigkeit modelliert wird. Die Gewebe werden als inkompressible, isotrop hyperelastische Materialien modelliert, während die Netze entweder als orthotrope linear elastische oder als isotrope hyperlastische Materialien modelliert werden. Die Positionen des Vaginalstumpfs, der Blase und der Harnröhrenachse werden anhand der Pubococcygeallinie aus der Ruhelage, für den Prolaps und nach der Reparatur unter Verwendung der drei Netze berechnet. Aufgrund der Netzmechanik und der Netzporenverformung bietet das DynaMesh mit regelmäßigen rechteckigen Netzporen eine bessere mechanische Unterstützung und eine Neupositionierung des Scheidengewölbes, der Blase und der Urethraachse als Gynemesh und Ultrapro mit unregelmäßigen hexagonalen Netzporen.
Prosthetic textile implants of different shapes, sizes and polymers are used to correct the apical prolapse after hysterectomy (removal of the uterus). The selection of the implant before or during minimally invasive surgery depends on the patient’s anatomical defect, intended function after reconstruction and most importantly the surgeon’s preference. Weakness or damage of the supporting tissues during childbirth, menopause or previous pelvic surgeries may put females in higher risk of prolapse. Numerical simulations of reconstructed pelvic floor with weakened tissues and organ supported by textile product models: DynaMesh®-PRS soft, DynaMesh®-PRP soft and DynaMesh®-CESA from FEG Textiletechnik mbH, Germany are compared.
Using the OpenSim software and verified anatomical data, a computer model for the calculation of biomechanical parameters is developed and used to determine the effect of a reattachment of the Supraspinatus muscle with a medial displacement of the muscle attachment point, which may be necessary for a rupture of the supraspinatus tendon. The results include the influence of the operation on basic biomechanical parameters such as the lever arm, as well as the calculated the muscle activations for the supraspinatus and deltoid. In addition, the influence on joint stability is examined by an analysis of the joint reaction force. The study provides a detailed description of the used model, as well as medical findings to a reattachment of the supraspinatus.
Mit der Software OpenSim und überprüften anatomischen Daten wird ein Computermodell zur Berechnung von biomechanischen Parametern entwickelt und genutzt, um den Effekt einer Refixierung des Supraspinatusmuskels mit einer medialen Verschiebung des Muskelansatzpunktes zu ermitteln, wie sie unter anderem nach einem Riss der Supraspinatussehne notwendig sein kann. Die Ergebnisse umfassen hierbei den Einfluss der Operation auf grundlegende biomechanische Parameter wie den Hebelarm sowie die berechneten Muskelaktivierungen für den Supraspinatus und Deltoideus. Zusätzlich wird der Einfluss auf die Gelenkstabilität betrachtet und durch eine Analyse der Gelenkreaktionskraft untersucht. Die Studie bietet eine detaillierte Beschreibung des genutzten Modells, sowie medizinische Erkenntnisse zu einer Refixierung des Supraspinatus.
In this study, polyelectrolyte-modified field-effect-based electrolyte-insulator-semiconductor (EIS) devices have been used for the label-free electrical detection of double-stranded deoxyribonucleic acid (dsDNA)molecules. The sensor-chip functionalization with a positively charged polyelectrolyte layer provides the possibility of direct adsorptive binding of negatively charged target DNA oligonucleotides onto theSiO2-chip surface.EIS sensors can be utilized as a tool to detect surface-charge changes; the electrostatic adsorption of oligonucleotides onto the polyelectrolyte layer leads to a measureable surface-potential change. Signals of 39mV have been recorded after the incubation with the oligonucleotide solution. Besides the electrochemical experiments, the successful adsorption of dsDNA onto the polyelectrolyte layer has been verified via fluorescence microscopy. The presented results demonstrate that the signal recording of EISchips, which are modified with a polyelectrolyte layer, canbe used as a favorable approach for a fast, cheap and simple detection method for dsDNA.
Intelligent autonomous software robots replacing human activities and performing administrative processes are reality in today’s corporate world. This includes, for example, decisions about invoice payments, identification of customers for a marketing campaign, and answering customer complaints. What happens if such a software robot causes a damage? Due to the complete absence of human activities, the question is not trivial. It could even happen that no one is liable for a damage towards a third party, which could create an uncalculatable legal risk for business partners. Furthermore, the implementation and operation of those software robots involves various stakeholders, which result in the unsolvable endeavor of identifying the originator of a damage. Overall it is advisable to all involved parties to carefully consider the legal situation. This chapter discusses the liability of software robots from an interdisciplinary perspective. Based on different technical scenarios the legal aspects of liability are discussed.
Robotic process automation (RPA) has attracted increasing attention in research and practice. This chapter positions, structures, and frames the topic as an introduction to this book. RPA is understood as a broad concept that comprises a variety of concrete solutions. From a management perspective RPA offers an innovative approach for realizing automation potentials, whereas from a technical perspective the implementation based on software products and the impact of artificial intelligence (AI) and machine learning (ML) are relevant. RPA is industry-independent and can be used, for example, in finance, telecommunications, and the public sector. With respect to RPA this chapter discusses definitions, related approaches, a structuring framework, a research framework, and an inside as well as outside architectural view. Furthermore, it provides an overview of the book combined with short summaries of each chapter.