Article
Refine
Year of publication
Document Type
- Article (5464) (remove)
Language
Has Fulltext
- no (5464) (remove)
Keywords
- avalanche (5)
- Earthquake (4)
- LAPS (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
- snow (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Chemometrics (2)
- Datenschutz (2)
- Datenschutzgrundverordnung (2)
- Drinfeld modules (2)
- Empirical process (2)
- Field-effect sensor (2)
- Goodness-of-fit test (2)
Institute
- Fachbereich Medizintechnik und Technomathematik (1531)
- Fachbereich Wirtschaftswissenschaften (683)
- Fachbereich Elektrotechnik und Informationstechnik (617)
- Fachbereich Energietechnik (597)
- Fachbereich Chemie und Biotechnologie (585)
- INB - Institut für Nano- und Biotechnologien (523)
- Fachbereich Maschinenbau und Mechatronik (463)
- IfB - Institut für Bioengineering (426)
- Fachbereich Luft- und Raumfahrttechnik (364)
- Fachbereich Bauingenieurwesen (324)
- Solar-Institut Jülich (105)
- Fachbereich Architektur (76)
- Fachbereich Gestaltung (55)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (39)
- ECSM European Center for Sustainable Mobility (33)
- Nowum-Energy (28)
- Sonstiges (23)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (18)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (15)
- IBB - Institut für Baustoffe und Baukonstruktionen (9)
- IMP - Institut für Mikrowellen- und Plasmatechnik (3)
- Verwaltung (3)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- FH Aachen (1)
- Kommission für Forschung und Entwicklung (1)
Edge-based and face-based smoothed finite element methods (ES-FEM and FS-FEM, respectively) are modified versions of the finite element method allowing to achieve more accurate results and to reduce sensitivity to mesh distortion, at least for linear elements. These properties make the two methods very attractive. However, their implementation in a standard finite element code is nontrivial because it requires heavy and extensive modifications to the code architecture. In this article, we present an element-based formulation of ES-FEM and FS-FEM methods allowing to implement the two methods in a standard finite element code with no modifications to its architecture. Moreover, the element-based formulation permits to easily manage any type of element, especially in 3D models where, to the best of the authors' knowledge, only tetrahedral elements are used in FS-FEM applications found in the literature. Shape functions for non-simplex 3D elements are proposed in order to apply FS-FEM to any standard finite element.
Automated driving is now possible in diverse road and traffic conditions. However, there are still situations that automated vehicles cannot handle safely and efficiently. In this case, a Transition of Control (ToC) is necessary so that the driver takes control of the driving. Executing a ToC requires the driver to get full situation awareness of the driving environment. If the driver fails to get back the control in a limited time, a Minimum Risk Maneuver (MRM) is executed to bring the vehicle into a safe state (e.g., decelerating to full stop). The execution of ToCs requires some time and can cause traffic disruption and safety risks that increase if several vehicles execute ToCs/MRMs at similar times and in the same area. This study proposes to use novel C-ITS traffic management measures where the infrastructure exploits V2X communications to assist Connected and Automated Vehicles (CAVs) in the execution of ToCs. The infrastructure can suggest a spatial distribution of ToCs, and inform vehicles of the locations where they could execute a safe stop in case of MRM. This paper reports the first field operational tests that validate the feasibility and quantify the benefits of the proposed infrastructure-assisted ToC and MRM management. The paper also presents the CAV and roadside infrastructure prototypes implemented and used in the trials. The conducted field trials demonstrate that infrastructure-assisted traffic management solutions can reduce safety risks and traffic disruptions.
Helle Fensterprofilmaterialien : Alterungsverhalten auf Basis von peroxidisch vernetztem EPDM
(2010)
Purpose
In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model.
Material and Methods
Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio).
Results
In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF.
Conclusion
The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018.
Ein Drittel der Mitarbeiter der Saint-Gobain Glass Deutschland
GmbH hat drei Jahre lang regelmäßig seinen Rücken trainiert.
Mit Erfolg, wie eine abschließende Evaluation in Zusammenarbeit
mit der FH Aachen zeigt. Die Fehltage der Trainingsteilnehmer
sind enorm zurückgegangen, während die untrainierten Kollegen
weiterhin unter Rückenbeschwerden leiden.