Article
Refine
Year of publication
- 2024 (16)
- 2023 (59)
- 2022 (75)
- 2021 (80)
- 2020 (93)
- 2019 (95)
- 2018 (83)
- 2017 (72)
- 2016 (78)
- 2015 (83)
- 2014 (93)
- 2013 (96)
- 2012 (80)
- 2011 (128)
- 2010 (119)
- 2009 (119)
- 2008 (102)
- 2007 (94)
- 2006 (86)
- 2005 (99)
- 2004 (131)
- 2003 (74)
- 2002 (92)
- 2001 (88)
- 2000 (84)
- 1999 (88)
- 1998 (82)
- 1997 (79)
- 1996 (70)
- 1995 (68)
- 1994 (76)
- 1993 (51)
- 1992 (48)
- 1991 (25)
- 1990 (35)
- 1989 (38)
- 1988 (54)
- 1987 (32)
- 1986 (18)
- 1985 (32)
- 1984 (18)
- 1983 (17)
- 1982 (26)
- 1981 (18)
- 1980 (35)
- 1979 (23)
- 1978 (30)
- 1977 (14)
- 1976 (13)
- 1975 (10)
- 1974 (3)
- 1972 (2)
- 1971 (1)
- 1968 (1)
Document Type
- Article (3226) (remove)
Language
- English (3226) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- biosensors (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- Label-free detection (3)
- additive manufacturing (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
- shakedown analysis (3)
- snow (3)
- tobacco mosaic virus (TMV) (3)
- Acyl-amino acids (2)
Institute
- Fachbereich Medizintechnik und Technomathematik (1343)
- INB - Institut für Nano- und Biotechnologien (501)
- Fachbereich Chemie und Biotechnologie (466)
- IfB - Institut für Bioengineering (408)
- Fachbereich Elektrotechnik und Informationstechnik (401)
- Fachbereich Energietechnik (360)
- Fachbereich Luft- und Raumfahrttechnik (247)
- Fachbereich Maschinenbau und Mechatronik (147)
- Fachbereich Wirtschaftswissenschaften (106)
- Fachbereich Bauingenieurwesen (68)
- Solar-Institut Jülich (43)
- ECSM European Center for Sustainable Mobility (27)
- Sonstiges (21)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (17)
- Nowum-Energy (16)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (15)
- Fachbereich Gestaltung (12)
- Fachbereich Architektur (9)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (5)
Multi-enzyme immobilization onto a capacitive field-effect biosensor by nano-spotting technique is presented. The nano-spotting technique allows to immobilize different enzymes simultaneously on the sensor surface with high spatial resolution without additional photolithographical patterning. The amount of applied enzymatic cocktail on the sensor surface can be tailored. Capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors with Ta2O5 as pH-sensitive transducer layer have been chosen to immobilize the three different (pL droplets) enzymes penicillinase, urease, and glucose oxidase. Nano-spotting immobilization is compared to conventional drop-coating method by defining different geometrical layouts on the sensor surface (fully, half-, and quarter-spotted). The drop diameter is varying between 84 µm and 102 µm, depending on the number of applied drops (1 to 4) per spot. For multi-analyte detection, penicillinase and urease are simultaneously nano-spotted on the EIS sensor. Sensor characterization was performed by C/V (capacitance/voltage) and ConCap (constant capacitance) measurements. Average penicillin, glucose, and urea sensitivities for the spotted enzymes were 81.7 mV/dec, 40.5 mV/dec, and 68.9 mV/dec, respectively.
A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.
The LAPS (light-addressable potentiometric sensor) platform is one of the most attractive approaches for chemical and biological sensing with many applications ranging from pH and ion/analyte concentration measurements up to cell metabolism detection and chemical imaging. However, although it is generally accepted that LAPS measurements are spatially resolved, the light-addressability feature of LAPS devices has not been discussed in detail so far. In this work, an extended electrical equivalent-circuit model of the LAPS has been presented, which takes into account possible cross-talk effects due to the capacitive coupling of the non-illuminated region. A shunting effect of the non-illuminated area on the measured photocurrent and addressability of LAPS devices has been studied. It has been shown, that the measured photocurrent will be determined not only by the local interfacial potential in the illuminated region but also by possible interfacial potential changes in the non-illuminated region, yielding cross-talk effects. These findings were supported by the experimental investigations of a penicillin-sensitive multi-spot LAPS and a metal-insulator-semiconductor LAPS as model systems.
An amperometric biosensor using a substrate recycling principle was realized for the detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and Ringer’s solution at pH 6.5 and pH 7.4, respectively. In proof-of-concept experiments, a Boolean logic-gate principle has been applied to develop a digital adrenaline biosensor based on an enzyme AND logic gate. The obtained results demonstrate that the developed digital biosensor is capable for a rapid qualitative determination of the presence/absence of adrenaline in a YES/NO statement. Such digital biosensor could be used in clinical diagnostics for the control of a correct insertion of a catheter in the adrenal veins during adrenal venous-sampling procedure.
Stored and cooled, highly-charged ions offer unprecedented capabilities for precision studies in the realm of atomic, nuclear structure and astrophysics[1]. After the successful investigation of the 96Ru(p,7)97Rh reaction cross section in 2009[2], the first measurement of the 124Xe(p,7)125Cs reaction cross section has been performed with decelerated, fully-ionized 124Xe ions in 2016 at the Experimental Storage Ring (ESR) of GSI[3]. Using a Double Sided Silicon Strip Detector, introduced directly into the ultra-high vacuum environment of a storage ring, the 125Cs proton-capture products have been successfully detected. The cross section has been measured at 5 different energies between 5.5AMeV and 8AMeV, on the high energy tail of the Gamow-window for hot, explosive scenarios such as supernovae and X-ray binaries. The elastic scattering on the H2 gas jet target is the major source of background to count the (p,7) events. Monte Carlo simulations show that an additional slit system in the ESR in combination with the energy information of the Si detector will enable background free measurements of the proton-capture products. The corresponding hardware is being prepared and will increase the sensitivity of the method tremendously.