Article
Refine
Year of publication
Document Type
- Article (117) (remove)
Has Fulltext
- no (117) (remove)
Keywords
- damage (2)
- Anastomotic leakage (1)
- Autolysis (1)
- Biocomposites (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Computational biomechanics (1)
- Constitutive model (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Discontinuous fractures (1)
- Distorsion des oberen Sprunggelenks (1)
- Drug simulation (1)
- ES-FEM (1)
- Electromechanical modeling (1)
- End-to-end colorectal anastomosis (1)
- FS-FEM (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Heart tissue culture (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Ion channels (1)
- Liver (1)
- Natural fibres (1)
- Non-parallel fissures (1)
- Pharmacology (1)
- Polymer-matrix composites (1)
- S-FEM (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Stress concentrations (1)
- Surgical staplers (1)
- Uniaxial compression test (1)
- Variable height stapler design (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- biaxial tensile experiment (1)
- chance constrained programming (1)
- constitutive modeling (1)
- dental trauma (1)
- difficult airway (1)
- distorted element (1)
- double-lumen tube intubation (1)
- fibulare Bandruptur (1)
- hiPS cardiomyocytes (1)
- hyperelastic (1)
- limit analysis (1)
- non-simplex S-FEM elements (1)
- reliability of structures (1)
- rupture of the fibular ligament (1)
- shakedown analysis (1)
- smooth muscle contraction (1)
- stochastic programming (1)
- strain energy function (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
Institute
Surgical reconstruction of the interosseous membrane (IOM) could restore longitudinal forearm stability to avoid persisting disability due to capituloradial and ulnocarpal impingement in Essex Lopresti lesions. This biomechanical study aimed to assess longitudinal forearm stability of intact specimens, after sectioning of the IOM and after reconstruction with a TightRope construct using either a single or double bundle technique.
Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis.
Pressure distribution to the distal biceps tendon at the radial tuberosity: a biomechanical study
(2020)
Purpose
Mechanical impingement at the narrow radioulnar space of the tuberosity is believed to be an etiological factor in the injury of the distal biceps tendon. The aim of the study was to compare the pressure distribution at the proximal radioulnar space between 2 fixation techniques and the intact state.
Methods
Six right arms and 6 left arms from 5 female and 6 male frozen specimens were used for this study. A pressure transducer was introduced at the height of the radial tuberosity with the intact distal biceps tendon and after 2 fixation methods: the suture-anchor and the cortical button technique. The force (N), maximum pressure (kPa) applied to the radial tuberosity, and the contact area (mm²) of the radial tuberosity with the ulna were measured and differences from the intact tendon were detected from 60° supination to 60° pronation in 15° increments with the elbow in full extension and in 45° and 90° flexion of the elbow.
Results
With the distal biceps tendon intact, the pressures during pronation were similar regardless of extension and flexion and were the highest at 60° pronation with 90° elbow flexion (23.3 ± 53.5 kPa). After repair of the tendon, the mean peak pressure, contact area, and total force showed an increase regardless of the fixation technique. Highest peak pressures were found using the cortical button technique at 45° flexion of the elbow and 60° pronation. These differences were significantly different from the intact tendon. The contact area was significantly larger in full extension and 15°, 30°, and 60° pronation using the cortical button technique.
Conclusions
Pressures on the distal biceps tendon at the radial tuberosity increase during pronation, especially after repair of the tendon.
Clinical relevance
Mechanical impingement could play a role in both the etiology of primary distal biceps tendon ruptures and the complications occurring after fixation of the tendon using certain techniques.