Article
Refine
Year of publication
- 2017 (72) (remove)
Document Type
- Article (72) (remove)
Language
- English (72) (remove)
Has Fulltext
- no (72) (remove)
Keywords
- 3D nonlinear finite element model (1)
- CNOT (1)
- Capacitive field-effect (1)
- Chemical images (1)
- Chemical sensor (1)
- Dehydrogenase (1)
- Diaphorase (1)
- Dry-low-NOx (DLN) combustion (1)
- EIS capacitive sensor (1)
- Effective modal mass (1)
- Electrolyte–insulator–semiconductor (1)
- Enzymatic biosensor (1)
- Enzyme logic gate (1)
- High hydrogen combustion (1)
- Hotelling’s T² test (1)
- Hydrogen combustion (1)
- Hydrogen gas turbine (1)
- LAPS (1)
- Light-addressable potentiometric sensor (1)
- Micromix combustion (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (41)
- INB - Institut für Nano- und Biotechnologien (23)
- IfB - Institut für Bioengineering (13)
- Fachbereich Chemie und Biotechnologie (11)
- Fachbereich Energietechnik (6)
- Fachbereich Bauingenieurwesen (5)
- Fachbereich Elektrotechnik und Informationstechnik (5)
- Fachbereich Luft- und Raumfahrttechnik (5)
- Institut fuer Angewandte Polymerchemie (3)
- Solar-Institut Jülich (3)
- ECSM European Center for Sustainable Mobility (1)
- Fachbereich Architektur (1)
- Fachbereich Maschinenbau und Mechatronik (1)
The integration of biomolecular logic principles with electronic transducers allows designing novel digital biosensors with direct electrical output, logically triggered drug-release, and closed-loop sense/act/treat systems. This opens new opportunities for advanced personalized medicine in the context of theranostics. In the present work, we will discuss selected examples of recent developments in the field of interfacing enzyme logic gates with electrodes and semiconductor field-effect devices. Special attention is given to an enzyme OR/Reset logic gate based on a capacitive field-effect electrolyte-insulator-semiconductor sensor modified with a multi-enzyme membrane. Further examples are a digital adrenaline biosensor based on an AND logic gate with binary YES/NO output and an integrated closed-loop sense/act/treat system comprising an amperometric glucose sensor, a hydrogel actuator, and an insulin (drug) sensor.
A high-Q resonance-mode measurement of EIS capacitive sensor by elimination of series resistance
(2017)
An EIS capacitive sensor is a semiconductor-based potentiometric sensor, which is sensitive to the ion concentration or pH value of the solution in contact with the sensing surface. To detect a small change in the ion concentration or pH, a small capacitance change must be detected. Recently, a resonance-mode measurement was proposed, in which an inductor was connected to the EIS capacitive sensor and the resonant frequency was correlated with the pH value. In this study, the Q factor of the resonant circuit was enhanced by canceling the internal resistance of the reference electrode and the internal resistance of the inductor coil with the help of a bypass capacitor and a negative impedance converter, respectively. 1% variation of the signal in the developed system corresponded to a pH change of 3.93 mpH, which was about 1/12 of the conventional method, suggesting a better performance in detection of a small pH change.
Altered neurovascular coupling as measured by optical imaging: a biomarker for Alzheimer’s disease
(2017)
This paper presents the results of an eigenvalue analysis of the Fatih Sultan Mehmet Bridge. A high-resolution finite element model was created directly from the available design documents. All physical properties of the structural components were included in detail, so no calibration to the measured data was necessary. The deck and towers were modeled with shell elements. A nonlinear static analysis was performed before the eigenvalue calculation. The calculated natural frequencies and corresponding mode shapes showed good agreement with the available measured ambient vibration data. The calculation of the effective modal mass showed that nine modes had single contributions higher than 5 % of the total mass. They were in a frequency range up to 1.2 Hz. The comparison of the results for the torsional modes especially demonstrated the advantage of using thin shell finite elements over the beam modeling approach.