Refine
Year of publication
- 2010 (317) (remove)
Document Type
- Article (175)
- Conference Proceeding (67)
- Book (37)
- Part of a Book (20)
- Patent (7)
- Report (4)
- Other (2)
- Contribution to a Periodical (1)
- Doctoral Thesis (1)
- Master's Thesis (1)
- Talk (1)
- Working Paper (1)
Has Fulltext
- no (317) (remove)
Keywords
- Geschichte (2)
- avalanche (2)
- Cardiovascular MRI (1)
- Commercial Vehicle (1)
- Common Rail Injection System (1)
- Diesel Engine (1)
- European Transient Cycle (1)
- Illustration (1)
- Left ventriular function (1)
- MR-stethoscope (1)
- Magnetic field strength (1)
- Magnetic resonance imaging (MRI) (1)
- Process virtualization (1)
- Product bundling (1)
- RAMMS (1)
- Selective Catalytic Reduction (1)
- Services (1)
- Telecommunication (1)
- Transformation (1)
- Typographie (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (68)
- Fachbereich Wirtschaftswissenschaften (41)
- IfB - Institut für Bioengineering (36)
- Fachbereich Elektrotechnik und Informationstechnik (34)
- Fachbereich Energietechnik (31)
- Fachbereich Maschinenbau und Mechatronik (31)
- Fachbereich Chemie und Biotechnologie (26)
- Fachbereich Luft- und Raumfahrttechnik (24)
- Fachbereich Bauingenieurwesen (23)
- INB - Institut für Nano- und Biotechnologien (23)
- Fachbereich Architektur (13)
- Solar-Institut Jülich (13)
- Fachbereich Gestaltung (5)
- Sonstiges (5)
- ECSM European Center for Sustainable Mobility (4)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
As the field strength and, therefore, the operational frequency in MRI is increased, the wavelength approaches the size of the human head/body, resulting in wave effects, which cause signal decreases and dropouts. Several multichannel approaches have been proposed to try to tackle these problems, including RF shimming, where each element in an array is driven by its own amplifier and modulated with a certain (constant) amplitude and phase relative to the other elements, and Transmit SENSE, where spatially tailored RF pulses are used. In this article, a relatively inexpensive and easy to use imaging scheme for 7 Tesla imaging is proposed to mitigate signal voids due to B1 field inhomogeneity. Two time-interleaved images are acquired using a different excitation mode for each. By forming virtual receive elements, both images are reconstructed together using GRAPPA to achieve a more homogeneous image, with only small SNR and SAR penalty in head and body imaging at 7 Tesla.