Refine
Year of publication
- 2016 (268) (remove)
Document Type
- Article (116)
- Conference Proceeding (80)
- Part of a Book (27)
- Book (23)
- Other (10)
- Report (5)
- Doctoral Thesis (3)
- Part of Periodical (2)
- Patent (1)
- Talk (1)
Keywords
- Technical Operations Research (2)
- Additive Manufacturing (1)
- Annulus Fibrosus (1)
- Assessment (1)
- Asymptotic efficiency (1)
- Bacillus atrophaeus (1)
- Balance (1)
- Balanced hypergraph (1)
- Brandfall (1)
- Building Systems (1)
- Business Simulations (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Censored data (1)
- Co-managed care (1)
- Collaborative robot (1)
- Computational biomechanics (1)
- Controller Parameter (1)
- DNA biosensor (1)
- Designpraxis (1)
- Disc Degeneration (1)
- Diversity (1)
- Drinking Water Supply (1)
- Drug simulation (1)
- Duality (1)
- EN 1993-1-2 (1)
- Effizienz (1)
- Einbetten in das Internet der Dinge (1)
- Elderly (1)
- Electromechanical modeling (1)
- Engineering Education (1)
- Eutectic Silver Copper alloy (1)
- External knee adduction moments (1)
- Fall prevention (1)
- Field effect (1)
- Forschung, pränormativ (1)
- Frequency adaption (1)
- Gamification (1)
- Gender (1)
- Ground-level falls (1)
- Hall’s Theorem (1)
- Heart tissue culture (1)
- Higher Education (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Human-Robot interaction (1)
- Hypergraph (1)
- Hypothesentests (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Ion channels (1)
- Koenig’s Theorem (1)
- LAPS (1)
- Label-free detection (1)
- Layer-by-layer adsorption (1)
- Level Control System (1)
- Manipulated variables (1)
- Matching (1)
- Minimal-Ansatz für Embedded-Systeme (1)
- Mixed Integer Programming (1)
- Mixed-Integer Nonlinear Optimisation (1)
- Mobility (1)
- Mobility tests (1)
- Musculoskeletal model (1)
- Nucleus Pulposus (1)
- Optimal Closed Loop (1)
- Optimal Topology (1)
- Optimization (1)
- Parametric Design (1)
- Parametric Modelling (1)
- Path planning (1)
- Pharmacology (1)
- Poly(allylamine hydrochloride) (1)
- Porositat (1)
- Product-integration (1)
- Reference Process Model (1)
- Referenzmodellierung (1)
- Response Surface Method (1)
- SLM (1)
- Safety concept (1)
- Semi-parametric random censorship model (1)
- Serious Games (1)
- Solver Per- formance (1)
- Structuralist Architecture (1)
- Subject-oriented Business Process Management (1)
- Survival analysis (1)
- System Design (1)
- System Design Problem (1)
- TM Forum (1)
- TTIP (1)
- Technical Operation Research (1)
- Telecommunications Industry. (1)
- Tinetti test (1)
- Tragwerksbemessung (1)
- Unternehmensarchitektur (1)
- Unternehmenstransformation (1)
- Vergleich von Experimenten (1)
- Vertex cover (1)
- Volterra integral equation (1)
- Workspace monitoring (1)
- biosensors (1)
- building industry (1)
- chemical sensor (1)
- diversity (1)
- eTOM (1)
- efficiency (1)
- electronic communications markets (1)
- endospores (1)
- energy disspation (1)
- engineering education (1)
- enhanced Telecom Operations Map (eTOM) (1)
- friction (1)
- hiPS cardiomyocytes (1)
- immobilization (1)
- impulsive effects (1)
- industrial research (1)
- ingot (1)
- innovation (1)
- iron and steel industry (1)
- liberalisation (1)
- light-addressable potentiometric sensor (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- materials technology (1)
- metal structure (1)
- organosilanes (1)
- plug-based microfluidic device (1)
- regulation (1)
- research project (1)
- research report (1)
- resistance of materials (1)
- seismic response (1)
- silanization (1)
- social responsible engineering (1)
- steel (1)
- structural design (1)
- structure-soil-structure interaction (1)
- testing hypotheses (1)
- wave run-up (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (54)
- Fachbereich Chemie und Biotechnologie (36)
- Fachbereich Bauingenieurwesen (35)
- Fachbereich Elektrotechnik und Informationstechnik (35)
- IfB - Institut für Bioengineering (35)
- Fachbereich Wirtschaftswissenschaften (31)
- Fachbereich Luft- und Raumfahrttechnik (27)
- Fachbereich Maschinenbau und Mechatronik (25)
- Fachbereich Energietechnik (17)
- INB - Institut für Nano- und Biotechnologien (15)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (11)
- Institut fuer Angewandte Polymerchemie (5)
- Nowum-Energy (5)
- Solar-Institut Jülich (5)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (5)
- ECSM European Center for Sustainable Mobility (4)
- Fachbereich Architektur (4)
- FH Aachen (2)
- IBB - Institut für Baustoffe und Baukonstruktionen (2)
- Fachbereich Gestaltung (1)
Größen, Formeln, Bemessung
(2016)
Das Kapitel 1 vermittelt eine Übersicht für den schnellen Gebrauch von Größen, Einheiten und Zeichen. Es folgt die Darstellung wichtiger Grundlagen der Mathematik, Lastannahmen und einfacher statischer Systeme. Schließlich werden Hinweise zu charakteristischen Festigkeiten und Tragfähigkeitsnachweisen für Berechnungen im Mauerwerk, Holz- und Stahlbau sowie Stahlbetonbau gegeben. Für eine weitere Vertiefung des Themas empfiehlt sich der Wendehorst Bautechnische Zahlentafel
This paper describes the results and methods used during the 8th Global Trajectory Optimization Competition (GTOC) of the DLR team. Trajectory optimization is crucial for most of the space missions and usually can be formulated as a global optimization problem. A lot of research has been done to different type of mission problems. The most demanding ones are low thrust transfers with e.g. gravity assist sequences. In that case the optimal control problem is combined with an integer problem. In most of the GTOCs we apply a filtering of the problem based on domain knowledge.
In this study, we show that synthetic sapphire (Al₂O₃), an established implant material, can also serve as a platform material for biosensors comparable to nanocrystalline diamond. Sapphire chips, beads, and powder were first modified with (3-aminopropyl) triethoxysilane (APTES), followed by succinic anhydride (SA), and finally single-stranded probe DNA was EDC coupled to the functionalized layer. The presence of the APTES-SA layer on sapphire powders was confirmed by thermogravimetric analyis and Fourier-transform infrared spectroscopy. Using planar sapphire chips as substrates and X-ray photoelectron spectroscopy (XPS) as surface-sensitive tool, the sequence of individual layers was analyzed with respect to their chemical state, enabling the quantification of areal densities of the involved molecular units. Fluorescence microscopy was used to demonstrate the hybridization of fluorescently tagged target DNA to the probe DNA, including denaturation- and re-hybridization experiments. Due to its high thermal conductivity, synthetic sapphire is especially suitable as a chip material for the heat-transfer method, which was employed to distinguish complementary- and non-complementary DNA duplexes containing single-nucleotide polymorphisms. These results indicate that it is possible to detect mutations electronically with a chemically resilient and electrically insulating chip material.
Abstractauthoren Graphene oxide (GO) nanoparticles were incorporated in temperature-sensitive Poly(N-isopropylacrylamide) (PNIPAAm) hydrogels. The nanoparticles increase the light absorption and convert light energy into heat efficiently. Thus, the hydrogels with GO can be stimulated spatially resolved by illumination as it was demonstrated by IR thermography. The temporal progression of the temperature maximum was detected for different concentrations of GO within the polymer network. Furthermore, the compatibility of PNIPAAm hydrogels with GO and cell cultures was investigated. For this purpose, culture medium was incubated with hydrogels containing GO and the viability and morphology of chinese hamster ovary (CHO) cells was examined after several days of culturing in presence of this medium.
The human arm consists of the humerus (upper arm), the medial ulna and the lateral radius (forearm). The joint between the humerus and the ulna is called humeroulnar joint and the joint between the humerus and the radius is called humeroradial joint. Lateral and medial collateral ligaments stabilize the elbow. Statistically, 2.5 out of 10,000 people suffer from radial head fractures [1]. In these fractures the cartilage is often affected. Caused by the injured cartilage, degenerative diseases like posttraumatic arthrosis may occur. The resulting pain and reduced range of motion have an impact on the patient’s quality of life. Until now, there has not been a treatment which allows typical loads in daily life activities and offers good long-term results. A new surgical approach was developed with the motivation to reduce the progress of the posttraumatic arthrosis. Here, the radius is shortened by 3 mm in the proximal part [2]. By this means, the load of the radius is intended to be reduced due to a load shift to the ulna. Since the radius is the most important stabilizer of the elbow it has to be confirmed that the stability is not affected. In the first test (Fig. 1 left), pressure distributions within the humeroulnar and humeroradial joints a native and a shortened radius were measured using resistive pressure sensors (I5076 and I5027, Tekscan, USA). The humerus was loaded axially in a tension testing machine (Z010, Zwick Roell, Germany) in 50 N steps up to 400 N. From the humerus the load is transmitted through both the radius and the ulna into the hand which is fixed on the ground. In the second test (Fig. 1 right), the joint stability was investigated using a digital image correlation system to measure the displacement of the ulna. Here, the humerus is fixed with a desired flexion angle and the unconstrained forearm lies on the ground. A rope connects the load actuator with a hook fixed in the ulna. A guide roller is used so that the rope pulls the ulna horizontally when a tensile load is applied. This creates a moment about the elbow joint with a maximum value of 7.5 Nm. Measurements were performed with varying flexion angles (0°, 30°, 60°, 90°, 120°). For both tests and each measurement, seven specimens were used. Student ́s t-test was employed to determine whether the mean values of the measurements in native specimen and operated specimens differ significantly.
This work presents a methodology for automated
damage-sensitive feature extraction and anomaly
detection under multivariate operational variability
for in-flight assessment of wings. The
method uses a passive excitation approach, i. e.
without the need for artificial actuation. The
modal system properties (natural frequencies and
damping ratios) are used as damage-sensitive
features. Special emphasis is placed on the use
of Fiber Bragg Grating (FBG) sensing technology
and the consideration of Operational and
Environmental Variability (OEV). Measurements
from a wind tunnel investigation with a composite
cantilever equipped with FBG and piezoelectric
sensors are used to successfully detect an impact
damage. In addition, the feasibility of damage
localisation and severity estimation is evaluated
based on the coupling found between damageand
OEV-induced feature changes.