Article
Refine
Year of publication
Document Type
- Article (5586) (remove)
Language
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- Rapid Prototyping (4)
- biosensors (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- Blitzschutz (3)
- CellDrum (3)
- Heparin (3)
- Label-free detection (3)
- additive manufacturing (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
Institute
- Fachbereich Medizintechnik und Technomathematik (1578)
- Fachbereich Wirtschaftswissenschaften (687)
- Fachbereich Elektrotechnik und Informationstechnik (625)
- Fachbereich Energietechnik (608)
- Fachbereich Chemie und Biotechnologie (597)
- INB - Institut für Nano- und Biotechnologien (540)
- Fachbereich Maschinenbau und Mechatronik (483)
- IfB - Institut für Bioengineering (448)
- Fachbereich Luft- und Raumfahrttechnik (373)
- Fachbereich Bauingenieurwesen (330)
- Solar-Institut Jülich (107)
- Fachbereich Architektur (79)
- Fachbereich Gestaltung (58)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (42)
- ECSM European Center for Sustainable Mobility (39)
- Nowum-Energy (34)
- Sonstiges (23)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (18)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (16)
Reliability of the Primary Circuit Pressure Boundary of an HTR-Module under Accident Conditions
(1993)
Objective
To investigate the feasibility of 7T MR imaging of the kidneys utilising a custom-built 8-channel transmit/receive radiofrequency body coil.
Methods
In vivo unenhanced MR was performed in 8 healthy volunteers on a 7T whole-body MR system. After B0 shimming the following sequences were obtained: 1) 2D and 3D spoiled gradient-echo sequences (FLASH, VIBE), 2) T1-weighted 2D in and opposed phase 3) True-FISP imaging and 4) a T2-weighted turbo spin echo (TSE) sequence. Visual evaluation of the overall image quality was performed by two radiologists.
Results
Renal MRI at 7T was feasible in all eight subjects. Best image quality was found using T1-weighted gradient echo MRI, providing high anatomical details and excellent conspicuity of the non-enhanced vasculature. With successful shimming, B1 signal voids could be effectively reduced and/or shifted out of the region of interest in most sequence types. However, T2-weighted TSE imaging remained challenging and strongly impaired because of signal heterogeneities in three volunteers.
Conclusion
The results demonstrate the feasibility and diagnostic potential of dedicated 7T renal imaging. Further optimisation of imaging sequences and dedicated RF coil concepts are expected to improve the acquisition quality and ultimately provide high clinical diagnostic value.
Prioritization is an essential task within requirements engineering to cope with complexity and to establish focus properly. The 3rd Workshop on Requirements Prioritization for customer oriented Software Development (RePriCo’12) focused on requirements prioritization and adjacent themes in the context of customer oriented development of bespoke and standard software. Five submissions have been accepted for the proceedings and for presentation. The report summarizes and points out key findings.