Refine
Year of publication
- 2018 (255) (remove)
Document Type
- Article (124)
- Conference Proceeding (77)
- Part of a Book (30)
- Book (12)
- Working Paper (3)
- Doctoral Thesis (2)
- Other (2)
- Patent (2)
- Part of Periodical (2)
- Report (1)
Keywords
- Datenschutz (2)
- Digitale Transformation (2)
- Energy efficiency (2)
- Engineering optimization (2)
- Literaturanalyse (2)
- MINLP (2)
- Pump System (2)
- Serious Game (2)
- Water (2)
- Agility (1)
- Antarctica (1)
- Awareness (1)
- Bahadur efficiency (1)
- Bioethanol (1)
- Biorefinery (1)
- Bladder (1)
- Booster Stations (1)
- Buffering Capacity (1)
- CDG (1)
- Chance Constraint (1)
- Chemical imaging (1)
- Cloud Computing (1)
- Coat protein (1)
- Competence Developing Game (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- Datenschutzgrundverordnung (1)
- Datenschutzrecht (1)
- Dry surfaces (1)
- EBSCO Discovery Service (1)
- EU-DS-GVO (1)
- EUDSGVO (1)
- Engineering Application (1)
- Enterprise Architecture (1)
- Enzyme nanocarrier (1)
- Equivalence test (1)
- Field-effect device (1)
- Forschungsprozess (1)
- GOSSAMER-1 (1)
- Geschäftsprozessmanagement (1)
- Global optimization (1)
- Glucose biosensor (1)
- Glucose oxidase (1)
- Goodness-of-fit tests for uniformity (1)
- Growth modelling (1)
- IBM Watson Explorer (1)
- INODIS (1)
- IT-Sicherheit (1)
- Identitätsmanagement (1)
- Informationsgetriebene Geschäftsmodelle (1)
- Integrated empirical distribution (survival) function (1)
- Internet der Dinge (1)
- Jupiter (1)
- Kernel density estimator (1)
- Lab-on-Chip (1)
- Latin Hypercube Sampling (1)
- Length of confidence intervals (1)
- Light-addressable potentiometric sensor (1)
- Lignocellulose feedstook (1)
- Literatur-analyse-prozess (1)
- Literaturdaten (1)
- Literature review (1)
- MASCOT (1)
- Mars (1)
- Mechanical simulation (1)
- Microbial adhesion (1)
- Minimum dissipation (1)
- Mixed-integer nonlinear problem (1)
- Monetarisierung (1)
- Multi-criteria optimization (1)
- Muscle fibers (1)
- Network (1)
- Numerical inversion of Laplace transforms (1)
- Paper recycling (1)
- Passive stretching (1)
- Pelvic floor dysfunction (1)
- Pelvic muscle (1)
- Pitman efficiency (1)
- Planetary exploration (1)
- Player Types (1)
- Potentiometry (1)
- Process engineering (1)
- Projektbeispiele (1)
- Prozessautomatisierung (1)
- Qualitative Wertschöpfungsanalyse (1)
- RC frames (1)
- Reconstruction (1)
- Rehabilitation Technology and Prosthetics (1)
- Research process (1)
- Sampling methods (1)
- Softwareroboter (1)
- Stochastic Programming (1)
- Story (1)
- Surface microorganisms (1)
- Surgical Navigation and Robotics (1)
- Swabbing (1)
- Technische Schutzmaßnahmen (1)
- Text Analytics (1)
- Text Analytics (1)
- Text analytics (1)
- Text mining (1)
- Tobacco mosaic virus (TMV) (1)
- Transition (1)
- Turbulence (1)
- Uncertainty (1)
- Ureter (1)
- Video Game (1)
- Water Distribution (1)
- Water Supply Networks (1)
- Wilcoxon tests (1)
- Wissenstransfer (1)
- achilles tendon (1)
- agile (1)
- business simulation (1)
- design of technical systems (1)
- earthquakes (1)
- energy absorption (1)
- energy dissipation (1)
- frequency mixing (1)
- functional data (1)
- habitability (1)
- huge dimensional data (1)
- ice moons (1)
- icy moons (1)
- in-plane and out-of-plane failure (1)
- legal obligations (1)
- life detection (1)
- magnetic beads (1)
- magnetic sensing (1)
- mathematical optimization (1)
- mechanical buffer (1)
- multiple NEA rendezvous (1)
- optimization (1)
- product liability (1)
- remote sensing (1)
- resilience (1)
- separable Hilbert space (1)
- slum classification (1)
- small spacecraft (1)
- solar sail (1)
- space missions (1)
- stiffness (1)
- superparamagnetic nanoparticles (1)
- tablet game (1)
- underwater vehicle (1)
- water supply design (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (67)
- Fachbereich Elektrotechnik und Informationstechnik (44)
- IfB - Institut für Bioengineering (41)
- INB - Institut für Nano- und Biotechnologien (25)
- Fachbereich Luft- und Raumfahrttechnik (24)
- Fachbereich Maschinenbau und Mechatronik (24)
- Fachbereich Energietechnik (22)
- Fachbereich Wirtschaftswissenschaften (21)
- Fachbereich Chemie und Biotechnologie (18)
- Fachbereich Bauingenieurwesen (16)
- Fachbereich Architektur (8)
- ECSM European Center for Sustainable Mobility (6)
- Solar-Institut Jülich (5)
- Fachbereich Gestaltung (4)
- Institut fuer Angewandte Polymerchemie (3)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (2)
- Nowum-Energy (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- FH Aachen (1)
Purpose
In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model.
Material and Methods
Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio).
Results
In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF.
Conclusion
The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018.
Malaria infection remains a significant risk for much of the population of tropical and subtropical areas, particularly in developing countries. Therefore, it is of high importance to develop sensitive, accurate and inexpensive malaria diagnosis tests. Here, we present a novel aptamer-based electrochemical biosensor (aptasensor) for malaria detection by impedance spectroscopy, through the specific recognition between a highly discriminatory DNA aptamer and its target Plasmodium falciparum lactate dehydrogenase (PfLDH). Interestingly, due to the isoelectric point (pI) of PfLDH, the aptasensor response showed an adjustable detection range based on the different protein net-charge at variable pH environments. The specific aptamer recognition allows sensitive protein detection with an expanded detection range and a low detection limit, as well as a high specificity for PfLDH compared to analogous proteins. The specific feasibility of the aptasensor is further demonstrated by detection of the target PfLDH in human serum. Furthermore, the aptasensor can be easily regenerated and thus applied for multiple usages. The robustness, sensitivity, and reusability of the presented aptasensor make it a promising candidate for point-of-care diagnostic systems.
An amperometric bi-enzyme biosensor based on substrate recycling principle for the amplification of the sensor signal has been developed for the detection of adrenaline in blood. Adrenaline can be used as biomarker verifying successful adrenal venous sampling procedure. The adrenaline biosensor has been realized via modification of a galvanic oxygen sensor with a bi-enzyme membrane combining a genetically modified laccase and a pyrroloquinoline quinone-dependent glucose dehydrogenase. The measurement conditions such as pH value and temperature were optimized to enhance the sensor performance. A high sensitivity and a low detection limit of about 0.5–1 nM adrenaline have been achieved in phosphate buffer at pH 7.4, relevant for measurements in blood samples. The sensitivity of the biosensor to other catecholamines such as noradrenaline, dopamine and dobutamine has been studied. Finally, the sensor has been successfully applied for the detection of adrenaline in human blood plasma.
Wireless CAN
(2018)
Das vorgestellte System zu Wireless CAN bietet die Möglichkeit, CAN kabellos zu übertragen. Beide vorgestellten und entwickelten Konzepte funktionieren korrekt und ermöglichen den Auf-bau von kabellosen CAN Schnittstellen. Durch den kleinen Aufbau kann diese Technologie auch für eingebettete Systeme verwendet werden. Zudem bietet dieser Ansatz die Möglichkeit, durch die Entwicklung von geeigneten ICs die Größe des Systems bis auf Bauteilgröße zu reduzieren, um eine noch bessere Integration in eingebettete Systeme zu ermöglichen. Dadurch wird die Technologie attraktiv für Einsatzgebiete, wo die oben aufgelisteten Vorteile zum Tragen kommen können. Diese Einsatzgebiete können sowohl im Automobil als auch im Industriebereich liegen.
Digitalisierung bezeichnet die Nutzung großer Datenmengen, die zu einer umfassenden Vernetzung aller Bereiche der Wirtschaft und Gesellschaft führen wird (BMWi, 2015 und ähnlich Köhler/Wollschläger, 2014: 79). Sie umfasst die Erhebung von analogen Informationen („Big Data“ in einem engen Sinne; z.B. O´Leary, 2013), ihre Speicherung in einem digitaltechnischen System (lokale Speicherung oder „Cloud Computing“ durch die Weiterentwickelung des Internets; z.B. Hashem et al., 2015: 101), die Analyse und Interpretation sowie den Transfer in andere Systeme („Internet der Dinge“ bzw. „Internet of Things“; z.B. Ashton, 2009).
Particularly multiparous elderly women may suffer from vaginal vault prolapse after hysterectomy due to weak support from lax apical ligaments. A decreased amount of estrogen and progesterone in older age is assumed to remodel the collagen thereby reducing tissue stiffness. Sacrocolpopexy is either performed as open or laparoscopic surgery using prosthetic mesh implants to substitute lax ligaments. Y-shaped mesh models (DynaMesh, Gynemesh, and Ultrapro) are implanted in a 3D female pelvic floor finite element model in the extraperitoneal space from the vaginal cuff to the first sacral (S1) bone below promontory. Numerical simulations are conducted during Valsalva maneuver with weakened tissues modeled by reduced tissue stiffness. Tissues are modeled as incompressible, isotropic hyperelastic materials whereas the meshes are modeled either as orthotropic linear elastic or as isotropic hyperlastic materials. The positions of the vaginal cuff and the bladder base are calculated from the pubococcygeal line for female pelvic floor at rest, for prolapse and after repair using the three meshes. Due to mesh mechanics and mesh pore deformation along the loaded direction, the DynaMesh with regular rectangular mesh pores is found to provide better mechanical support to the organs than the Gynemesh and the Ultrapro with irregular hexagonal mesh pores.
Insbesondere ältere, mehrgebährende Frauen leiden häufiger an einem Scheidenvorfall nach einer Hysterektomie aufgrund der schwachen Unterstützung durch laxe apikale Bänder. Es wird angenommen, dass eine verringerte Menge an Östrogen und Progesteron im höheren Alter das Kollagen umformt, wodurch die Gewebesteifigkeit reduziert wird. Die Sakrokolpopexie ist eine offene oder laparoskopische Operation, die mit prothetischen Netzimplantaten durchgeführt wird, um laxe Bänder zu ersetzen. Y-förmige Netzmodelle (DynaMesh, Gynemesh und Ultrapro) werden in einem 3D-Modell des weiblichen Beckenbodens im extraperitonealen Raum vom Vaginalstumpf bis zum Promontorium implantiert. Numerische Simulationen werden während des Valsalva-Manövers mit geschwächtem Gewebe durchgeführt, das durch eine reduzierte Gewebesteifigkeit modelliert wird. Die Gewebe werden als inkompressible, isotrop hyperelastische Materialien modelliert, während die Netze entweder als orthotrope linear elastische oder als isotrope hyperlastische Materialien modelliert werden. Die Positionen des Vaginalstumpfs, der Blase und der Harnröhrenachse werden anhand der Pubococcygeallinie aus der Ruhelage, für den Prolaps und nach der Reparatur unter Verwendung der drei Netze berechnet. Aufgrund der Netzmechanik und der Netzporenverformung bietet das DynaMesh mit regelmäßigen rechteckigen Netzporen eine bessere mechanische Unterstützung und eine Neupositionierung des Scheidengewölbes, der Blase und der Urethraachse als Gynemesh und Ultrapro mit unregelmäßigen hexagonalen Netzporen.
Using the OpenSim software and verified anatomical data, a computer model for the calculation of biomechanical parameters is developed and used to determine the effect of a reattachment of the Supraspinatus muscle with a medial displacement of the muscle attachment point, which may be necessary for a rupture of the supraspinatus tendon. The results include the influence of the operation on basic biomechanical parameters such as the lever arm, as well as the calculated the muscle activations for the supraspinatus and deltoid. In addition, the influence on joint stability is examined by an analysis of the joint reaction force. The study provides a detailed description of the used model, as well as medical findings to a reattachment of the supraspinatus.
Mit der Software OpenSim und überprüften anatomischen Daten wird ein Computermodell zur Berechnung von biomechanischen Parametern entwickelt und genutzt, um den Effekt einer Refixierung des Supraspinatusmuskels mit einer medialen Verschiebung des Muskelansatzpunktes zu ermitteln, wie sie unter anderem nach einem Riss der Supraspinatussehne notwendig sein kann. Die Ergebnisse umfassen hierbei den Einfluss der Operation auf grundlegende biomechanische Parameter wie den Hebelarm sowie die berechneten Muskelaktivierungen für den Supraspinatus und Deltoideus. Zusätzlich wird der Einfluss auf die Gelenkstabilität betrachtet und durch eine Analyse der Gelenkreaktionskraft untersucht. Die Studie bietet eine detaillierte Beschreibung des genutzten Modells, sowie medizinische Erkenntnisse zu einer Refixierung des Supraspinatus.
In this work, a spore-based biosensor is evaluated to monitor the microbicidal efficacy of sterilization processes applying gaseous hydrogen peroxide (H2O2). The sensor is based on interdigitated electrode structures (IDEs) that have been fabricated by means of thin-film technologies. Impedimetric measurements are applied to study the effect of sterilization process on spores of Bacillus atrophaeus. This resilient microorganism is commonly used in industry to proof the sterilization efficiency. The sensor measurements are accompanied by conventional microbiological challenge tests, as well as morphological characterizations with scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The sensor measurements are correlated with the microbiological test routines. In both methods, namely the sensor-based and microbiological one, a tailing effect has been observed. The results are evaluated and discussed in a three-dimensional calibration plot demonstrating the sensor's suitability to enable a rapid process decision in terms of a successfully performed sterilization.