Refine
Year of publication
Document Type
- Article (5586)
- Conference Proceeding (1620)
- Book (1078)
- Part of a Book (548)
- Bachelor Thesis (297)
- Patent (172)
- Report (100)
- Doctoral Thesis (78)
- Other (77)
- Administrative publication (76)
- Part of Periodical (63)
- Lecture (30)
- Master's Thesis (20)
- Contribution to a Periodical (19)
- Review (17)
- Diploma Thesis (15)
- Working Paper (13)
- Course Material (9)
- Talk (7)
- Study Thesis (5)
Language
- German (5012)
- English (4801)
- Russian (14)
- Portuguese (6)
- Multiple languages (5)
- Spanish (3)
- nld (2)
- Italien (1)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Illustration (21)
- Studien- und Prüfungsordnung (21)
- Aachen / Fachhochschule Aachen (20)
- Änderungsordnung (20)
- Blitzschutz (18)
- Corporate Design (17)
- Elektromobilität (17)
- CAD (16)
- Finite-Elemente-Methode (16)
- Fotografie (16)
- civil engineering (14)
Institute
- Fachbereich Medizintechnik und Technomathematik (2052)
- Fachbereich Elektrotechnik und Informationstechnik (1150)
- Fachbereich Wirtschaftswissenschaften (1138)
- Fachbereich Energietechnik (1104)
- Fachbereich Maschinenbau und Mechatronik (866)
- Fachbereich Chemie und Biotechnologie (847)
- Fachbereich Luft- und Raumfahrttechnik (776)
- Fachbereich Bauingenieurwesen (705)
- IfB - Institut für Bioengineering (686)
- INB - Institut für Nano- und Biotechnologien (613)
- Fachbereich Gestaltung (484)
- Solar-Institut Jülich (339)
- Fachbereich Architektur (174)
- FH Aachen (153)
- ECSM European Center for Sustainable Mobility (112)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (74)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (71)
- Nowum-Energy (70)
- Institut fuer Angewandte Polymerchemie (32)
- Sonstiges (24)
- IBB - Institut für Baustoffe und Baukonstruktionen (22)
- Freshman Institute (19)
- Kommission für Forschung und Entwicklung (18)
- Verwaltung (11)
- IaAM - Institut für angewandte Automation und Mechatronik (4)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (3)
- IMP - Institut für Mikrowellen- und Plasmatechnik (3)
- Datenverarbeitungszentrale (1)
- Digitalisierung in Studium & Lehre (1)
Die Erfindung betrifft ein Kaltstartverfahren für eine Mehrzylinder-Kolbenbrennkraftmaschine mit Anlasser und einer Motorsteuerung zur Ansteuerung von Kraftstoffeinspritzeinrichtungen, Zündung und voll variabel elektromagnetisch betätigbaren Gaswechselventilen an den einzelnen Zylindern, bei dem die Kurbelwelle über den Anlasser gedreht wird und zum Start für wenigstens einen Zylinder die dazugehörigen Gaswechselventile, die Kraftstoffeinspritzeinrichtung und die Zündung in einem vorgegebenen Taktzyklus angesteuert werden und zwar in den ersten Arbeitszyklen mit "Spätem Einlaß Öffnen".
Sensitive and rapid detection of cholera toxin subunit B using magnetic frequency mixing detection
(2019)
Cholera is a life-threatening disease caused by the cholera toxin (CT) as produced by some Vibrio cholerae serogroups. In this research we present a method which directly detects the toxin’s B subunit (CTB) in drinking water. For this purpose we performed a magnetic sandwich immunoassay inside a 3D immunofiltration column. We used two different commercially available antibodies to capture CTB and for binding to superparamagnetic beads. ELISA experiments were performed to select the antibody combination. The beads act as labels for the magnetic frequency mixing detection technique. We show that the limit of detection depends on the type of magnetic beads. A nonlinear Hill curve was fitted to the calibration measurements by means of a custom-written python software. We achieved a sensitive and rapid detection of CTB within a broad concentration range from 0.2 ng/ml to more
than 700 ng/ml.
Elektromagnetischer Aktuator zur Betätigung eines Stellgliedes (2), mit wenigstens einem Elektromagneten (4) und einem mit dem Stellglied (2) verbundenen Anker (3), der gegen die Kraft einer Rückstellfeder (6) aus seiner Ruhelage in Richtung auf den Elektromagneten (4) bewegbar ist, mit einer Rückstellfeder (6), die eine nicht lineare, bezogen auf die Ruhelage des Ankers (3) progressiv ansteigende Kennlinie aufweist.
Die qualitative und quantitative Detektion von Zielsubstanzen innerhalb einer wässrigen Probe ist für viele Fragestellungen von Interesse, etwa bei der Detektion von Kontaminationen in Trinkwasser in Krisensituationen. Hierbei ist es nicht nur wichtig, dass Pathogene möglichst sensitiv detektiert werden können, sondern auch, dass die Analyse schnell erfolgt, um Betroffenen im Katastrophenfall zügig sicheres Trinkwasser zu Verfügung stellen zu können. Da bei einem solchen Szenario nicht von einer in der Nähe befindlichen funktionierenden Laborinfrastruktur ausgegangen werden kann, ist es wichtig, dass die Messung direkt vor Ort erfolgen kann. Im Rahmen dieser Arbeit wurde untersucht, ob eine derartige Schnellanalytik mithilfe von superparamagnetischen Beads (MBs) und der magnetischen Frequenzmischtechnik möglich ist. Dabei werden die MBs mit Hilfe von primären Antikörpern an die Zielsubstanz gebunden und mit sekundären Antikörpern an die Poren-Oberfläche eines Polyethylen-Filters fixiert (Sandwich-Immunoassay). So kann die Quantifizierung der Zielsubstanz auf eine magnetische Messung der immobilisierten MB-Marker zurückgeführt werden. Die magnetische Frequenzmischtechnik basiert auf der Anregung der Probe mit Magnetfeldern zweier verschiedener Frequenzen. Die durch die nichtlineare Magnetisierungsform der superparamagnetischen MBs entstehenden Mischfrequenzen werden typischerweise mithilfe einer zweistufigen Lock-in-Detektion analysiert (analoge Demodulation), die in einem Magnetreader als Handheldgerät realisiert wurde. Zusätzlich zu dieser Technik wurde das Prinzip der direkten Digitalisierung des gesamten Antwortsignals mit anschließender Fourier-Analyse der erzeugten Mischfrequenzen experimentell umgesetzt, um die Amplituden und Phasen mehrerer Mischfrequenzen simultan zu erfassen. Eine Möglichkeit zur Sensitivitätssteigerung ist die magnetische Aufkonzentration, indem vor der magnetischen Analyse eine Separation der MBs aus einem größeren Probenvolumen mittels magnetischem Feldgradienten durchgeführt wird. Zur Charakterisierung verschiedener kommerzieller MBs hinsichtlich ihrer magnetischen Separierbarkeit wurde ein Aufbau zur Messung ihrer magnetophoretischen Beweglichkeiten realisiert und ihre Geschwindigkeiten im Gradientenfeld mikroskopisch gemessen.Da eine Probe oftmals nicht nur auf eine einzige Zielsubstanz, sondern simultan auf mehrere verschiedene Pathogene hin untersucht werden soll, wurden verschiedene Ansätze entwickelt und getestet, die einen solchen multiparametrischen magnetischen Immunoassay ermöglichen. Einerseits wurde eine räumliche Separation der Bindungsbereiche für verschiedene Zielsubstanzen realisiert, die sequentiell ausgewertet werden können. Andererseits wurde die Unterscheidung von verschiedenen Zielsubstanzen anhand der Charakteristika der an sie gebundenen, verschieden funktionalisierten MB-Typen untersucht. Für eine solche Unterscheidung wurde zum einen die Anregefrequenz der magnetischen Frequenzmischtechnik während einer Messung variiert. Damit konnte gezeigt werden, dass sich verschiedene MB-Sorten anhand der Phase ihrer Frequenzmischsignale voneinander unterscheiden lassen. Weiterhin wurde gezeigt, dass sich der Signalverlauf einer binären Mischung zweier verschiedener MB-Typen als gradueller Übergang der Verläufe der beiden reinen MB-Lösungen ergibt. Eine weitere Analysemethode für einen multiparametrischen Immunoassay besteht darin, ein zusätzliches einstellbares statisches magnetisches Offsetfeld zu verwenden. Hierfür wurden mehrere Aufbauten auf Basis von Permanent- und Elektromagneten simuliert, konstruiert und charakterisiert. Mithilfe von Simulationen konnte gezeigt werden, dass eine auf diesem Verfahren beruhende Unterscheidung für MBs mit unterschiedlichen magnetischen Partikelmomenten möglich ist. Als direkte Anwendung des hier entwickelten Magnetreaders in Zusammenspiel mit der digitalen Demodulation wurde ein magnetischer Assay gegen die B-Untereinheit des Choleratoxins in Trinkwasser mit einem niedrigen Detektionslimit von 0,2 ng/ml demonstriert.
Herein, fibroin, polylactide (PLA), and carbon are investigated for their suitability as biocompatible and biodegradable materials for amperometric biosensors. For this purpose, screen-printed carbon electrodes on the biodegradable substrates fibroin and PLA are modified with a glucose oxidase membrane and then encapsulated with the biocompatible material Ecoflex. The influence of different curing parameters of the carbon electrodes on the resulting biosensor characteristics is studied. The morphology of the electrodes is investigated by scanning electron microscopy, and the biosensor performance is examined by amperometric measurements of glucose (0.5–10 mM) in phosphate buffer solution, pH 7.4, at an applied potential of 1.2 V versus a Ag/AgCl reference electrode. Instead of Ecoflex, fibroin, PLA, and wound adhesive are tested as alternative encapsulation compounds: a series of swelling tests with different fibroin compositions, PLA, and Ecoflex has been performed before characterizing the most promising candidates by chronoamperometry. Therefore, the carbon electrodes are completely covered with the particular encapsulation material. Chronoamperometric measurements with H2O2 concentrations between 0.5 and 10 mM enable studying the leakage current behavior.
It has been shown that muscle fascicle curvature increases with increasing contraction level and decreasing muscle–tendon complex length. The analyses were done with limited examination windows concerning contraction level, muscle–tendon complex length, and/or intramuscular position of ultrasound imaging. With this study we aimed to investigate the correlation between fascicle arching and contraction, muscle–tendon complex length and their associated architectural parameters in gastrocnemius muscles to develop hypotheses concerning the fundamental mechanism of fascicle curving. Twelve participants were tested in five different positions (90°/105°*, 90°/90°*, 135°/90°*, 170°/90°*, and 170°/75°*; *knee/ankle angle). They performed isometric contractions at four different contraction levels (5%, 25%, 50%, and 75% of maximum voluntary contraction) in each position. Panoramic ultrasound images of gastrocnemius muscles were collected at rest and during constant contraction. Aponeuroses and fascicles were tracked in all ultrasound images and the parameters fascicle curvature, muscle–tendon complex strain, contraction level, pennation angle, fascicle length, fascicle strain, intramuscular position, sex and age group were analyzed by linear mixed effect models. Mean fascicle curvature of the medial gastrocnemius increased with contraction level (+5 m−1 from 0% to 100%; p = 0.006). Muscle–tendon complex length had no significant impact on mean fascicle curvature. Mean pennation angle (2.2 m−1 per 10°; p < 0.001), inverse mean fascicle length (20 m−1 per cm−1; p = 0.003), and mean fascicle strain (−0.07 m−1 per +10%; p = 0.004) correlated with mean fascicle curvature. Evidence has also been found for intermuscular, intramuscular, and sex-specific intramuscular differences of fascicle curving. Pennation angle and the inverse fascicle length show the highest predictive capacities for fascicle curving. Due to the strong correlations between pennation angle and fascicle curvature and the intramuscular pattern of curving we suggest for future studies to examine correlations between fascicle curvature and intramuscular fluid pressure.
Quantitative evaluation of health management designs for fuel cell systems in transport vehicles
(2022)
Focusing on transport vehicles, mainly with regard to aviation applications, this paper presents compilation and subsequent quantitative evaluation of methods aimed at building an optimum integrated health management solution for fuel cell systems. The methods are divided into two different main types and compiled in a related scheme. Furthermore, different methods are analysed and evaluated based on parameters specific to the aviation context of this study. Finally, the most suitable method for use in fuel cell health management systems is identified and its performance and suitability is quantified.
In addition to electromobility and alternative drive systems, a focus is set on electrically driven compressors (EDC), with a high potential for increasing the efficiency of internal combustion engines (ICE) and fuel cells [01]. The primary objective is to increase the ICE torque, provided independently of the ICE speed by compressing the intake air and consequently the ICE filling level supported by the compressor. For operation independent from the ICE speed, the EDC compressor is decoupled from the turbine by using an electric compressor motor (CM) instead of the turbine. ICE performances can be increased by the use of EDC where individual compressor parameters are adapted to the respective application area [02] [03]. This task contains great challenges, increased by demands with regard to pollutant reduction while maintaining constant performance and reduced fuel consumption. The FH-Aachen is equipped with an EDC test bench which enables EDC-investigations in various configurations and operating modes. Characteristic properties of different compressors can be determined, which build the basis for a comparison methodology. Subject of this project is the development of a comparison methodology for EDC with an associated evaluation method and a defined overall evaluation method. For the application of this comparison methodology, corresponding series of measurements are carried out on the EDC test bench using an appropriate test device.
Having well-defined control strategies for fuel cells, that can efficiently detect errors and take corrective action is critically important for safety in all applications, and especially so in aviation. The algorithms not only ensure operator safety by monitoring the fuel cell and connected components, but also contribute to extending the health of the fuel cell, its durability and safe operation over its lifetime. While sensors are used to provide peripheral data surrounding the fuel cell, the internal states of the fuel cell cannot be directly measured. To overcome this restriction, Kalman Filter has been implemented as an internal state observer.
Other safety conditions are evaluated using real-time data from every connected sensor and corrective actions automatically take place to ensure safety. The algorithms discussed in this paper have been validated thorough Model-in-the-Loop (MiL) tests as well as practical validation at a dedicated test bench.
The industrial revolution IR4.0 era have driven many states of the art technologies to be introduced especially in the automotive industry. The rapid development of automotive industries in Europe have created wide industry gap between European Union (EU) and developing countries such as in South-East Asia (SEA). Indulging this situation, FH Joanneum, Austria together with European partners from FH Aachen, Germany and Politecnico Di Torino, Italy is taking initiative to close the gap utilizing the Erasmus+ United grant from EU. A consortium was founded to engage with automotive technology transfer using the European ramework to Malaysian, Indonesian and Thailand Higher Education Institutions (HEI) as well as automotive industries. This could be achieved by establishing Engineering Knowledge Transfer Unit (EKTU) in respective SEA institutions guided by the industry partners in their respective countries. This EKTU could offer updated, innovative, and high-quality training courses to increase graduate’s employability in higher education institutions and strengthen relations between HEI and the wider economic and social environment by addressing Universityindustry cooperation which is the regional priority for Asia. It is expected that, the Capacity Building Initiative would improve the quality of higher education and enhancing its relevance for the labor market and society in the SEA partners. The outcome of this project would greatly benefit the partners in strong and complementary partnership targeting the automotive industry and enhanced larger scale international cooperation between the European and SEA partners. It would also prepare the SEA HEI in sustainable partnership with Automotive industry in the region as a mean of income generation in the future.