Refine
Year of publication
- 2016 (154) (remove)
Document Type
- Article (78)
- Conference Proceeding (65)
- Part of a Book (7)
- Book (2)
- Doctoral Thesis (1)
- Report (1)
Language
- English (154) (remove)
Keywords
- Technical Operations Research (2)
- Additive Manufacturing (1)
- Annulus Fibrosus (1)
- Assessment (1)
- Asymptotic efficiency (1)
- Bacillus atrophaeus (1)
- Balance (1)
- Balanced hypergraph (1)
- Building Systems (1)
- Business Simulations (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Censored data (1)
- Co-managed care (1)
- Collaborative robot (1)
- Computational biomechanics (1)
- Controller Parameter (1)
- DNA biosensor (1)
- Disc Degeneration (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (43)
- IfB - Institut für Bioengineering (29)
- Fachbereich Chemie und Biotechnologie (26)
- Fachbereich Elektrotechnik und Informationstechnik (26)
- Fachbereich Luft- und Raumfahrttechnik (21)
- Fachbereich Bauingenieurwesen (13)
- INB - Institut für Nano- und Biotechnologien (13)
- Fachbereich Maschinenbau und Mechatronik (12)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (11)
- Fachbereich Energietechnik (10)
- Institut fuer Angewandte Polymerchemie (5)
- ECSM European Center for Sustainable Mobility (4)
- Fachbereich Wirtschaftswissenschaften (3)
- Nowum-Energy (3)
- Fachbereich Architektur (2)
- Fachbereich Gestaltung (1)
- Solar-Institut Jülich (1)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (1)
Application of the optical flow method to velocity determination in hydraulic structure models
(2016)
The aim of this work was to perform a detailed investigation of the use of Selective Laser Melting (SLM) technology to process eutectic silver-copper alloy Ag 28 wt. % Cu (also called AgCu28). The processing occurred with a Realizer SLM 50 desktop machine. The powder analysis (SEM-topography, EDX, particle distribution) was reported as well as the absorption rates for the near-infrared (NIR) spectrum. Microscope imaging showed the surface topography of the manufactured parts. Furthermore, microsections were conducted for the analysis of porosity. The Design of Experiments approach used the response surface method in order to model the statistical relationship between laser power, spot distance and pulse time.
Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study
(2016)
Background
Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH.
Methods
In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2–14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling.
Results
Image quality was satisfactory in the majority of cases (93.3%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion.
Conclusion
RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort.