Article
Refine
Year of publication
- 2018 (124) (remove)
Document Type
- Article (124) (remove)
Keywords
- Bahadur efficiency (1)
- Booster Stations (1)
- Buffering Capacity (1)
- Chance Constraint (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- EBSCO Discovery Service (1)
- Engineering Application (1)
- Equivalence test (1)
- Forschungsprozess (1)
- Goodness-of-fit tests for uniformity (1)
- IBM Watson Explorer (1)
- Integrated empirical distribution (survival) function (1)
- Kernel density estimator (1)
- Lab-on-Chip (1)
- Length of confidence intervals (1)
- Literaturanalyse (1)
- MINLP (1)
- Numerical inversion of Laplace transforms (1)
- Pitman efficiency (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (46)
- IfB - Institut für Bioengineering (22)
- INB - Institut für Nano- und Biotechnologien (19)
- Fachbereich Elektrotechnik und Informationstechnik (13)
- Fachbereich Maschinenbau und Mechatronik (13)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Wirtschaftswissenschaften (12)
- Fachbereich Energietechnik (9)
- Fachbereich Bauingenieurwesen (7)
- Fachbereich Luft- und Raumfahrttechnik (7)
- Fachbereich Architektur (3)
- ECSM European Center for Sustainable Mobility (2)
- Institut fuer Angewandte Polymerchemie (2)
- Nowum-Energy (2)
- Fachbereich Gestaltung (1)
- Solar-Institut Jülich (1)
The Carologistics team participates in the RoboCup Logistics League for the seventh year. The RCLL requires precise vision,
manipulation and path planning, as well as complex high-level decision
making and multi-robot coordination. We outline our approach with an
emphasis on recent modifications to those components.
The team members in 2018 are David Bosen, Christoph Gollok, Mostafa
Gomaa, Daniel Habering, Till Hofmann, Nicolas Limpert, Sebastian Schönitz,
Morian Sonnet, Carsten Stoffels, and Tarik Viehmann.
This paper is based on the last year’s team description.
The porosity of surgical meshes makes them flexible for large elastic deformation and establishes the healing conditions of good tissue in growth. The biomechanic modeling of orthotropic and compressible materials requires new materials models and simulstaneoaus fit of deformation in the load direction as well as trannsversely to to load. This nonlinear modeling can be achieved by an optical deformation measurement. At the same time the full field deformation measurement allows the dermination of the change of porosity with deformation. Also the socalled effective porosity, which has been defined to asses the tisssue interatcion with the mesh implants, can be determined from the global deformation of the surgical meshes.
Wireless CAN
(2018)
In modernen elektronischen und mechatronischen Systemen, z. B. im industriellen oder automobil Bereich, kommunizieren eingebettete Steuergeräte und Sensoren vielfach über Bussysteme wie CAN oder LIN. Die Kommunikation findet in der Regel drahtgebunden statt, so dass der Kabelbaum für die Kommunikation sehr groß werden kann. Daher ist es naheliegend, Leitungen und dazugehörige Stecker, z. B. für nicht-sicherheitskritische Komfortsysteme, einzusparen und diese durch gerichtete Funkstrecken für kurze Entfernungen zu ersetzen. Somit könnten Komponenten wie ECUs oder Sensoren kabel- und steckerlos in ein Bussystem integriert werden. Zudem ist eine einfache galvanische und mechanische Trennung zu erreichen. Funkübertragung wird bei diesen Bussystemen derzeit nicht eingesetzt, da insbesondere die Echtzeitfähigkeit und die Robustheit der vorhandenen Funksysteme nicht den Anforderungen der Anwendungen entspricht. Zudem sind bestehende Funksysteme wie WLAN oder Bluetooth im Vergleich zur konventionellen Verkabelung teuer und es besteht hierbei die Möglichkeit, dass sie ausspioniert werden können und so sensible Daten entwendet werden können. In dieser Arbeit wird eine alternative Realisierung zu den bestehenden Funksystemen vorgestellt, die aus wenigen Komponenten aufzubauen ist. Es ist eine protokolllose, echtzeitfähige Übertragung möglich und somit die transparente Integration in ein Bussystem wie CAN.
The integration of sensors is one of the major tasks in embedded, control and “internet of things” (IoT) applications. For the integration mainly digital interfaces are used, starting from rather simple pulse-width modulation (PWM) interface to more complex interfaces like CAN (Controller Area Network). Even though these interfaces are tethered by definition, a wireless realization is highly welcome in many applications to reduce cable and connector cost, increase the flexibility and realize new emerging applications like wireless control systems. Currently used wireless solutions like Bluetooth, WirelessHART or IO-Link Wireless use dedicated communication standards and corresponding higher protocol layers to realize the wireless communication. Due to the complexity of the communication and the protocol handling, additional latency and jitter are introduced to the data communication that can meet the requirements for many applications. Even though tunnelling of other bus data like CAN data is generally also possible the latency and jitter prevent the tunnelling from being transparent for the bus system. Therefore a new basic technology based on dual-mode radio is used to realize a wireless communication on the physical layer only, enabling a reliable and real-time data transfer. As this system operates on the physical layer it is independent of any higher layers of the OSI (open systems interconnection) model. Hence it can be used for several different communication systems to replace the tethered physical layer. A prototype is developed and tested for real-time wireless PWM, SENT (single-edge nibble transmission) and CAN data transfer with very low latency and jitter.
In this work, a cell-based biosensor to evaluate the sterilization efficacy of hydrogen peroxide vapor sterilization processes is characterized. The transducer of the biosensor is based on interdigitated gold electrodes fabricated on an inert glass substrate. Impedance spectroscopy is applied to evaluate the sensor behavior and the alteration of test microorganisms due to the sterilization process. These alterations are related to changes in relative permittivity and electrical conductivity of the bacterial spores. Sensor measurements are conducted with and without bacterial spores (Bacillus atrophaeus), as well as after an industrial sterilization protocol. Equivalent two-dimensional numerical models based on finite element method of the periodic finger structures of the interdigitated gold electrodes are designed and validated using COMSOL® Multiphysics software by the application of known dielectric properties. The validated models are used to compute the electrical properties at different sensor states (blank, loaded with spores, and after sterilization). As a final result, we will derive and tabulate the frequency-dependent electrical parameters of the spore layer using a novel model that combines experimental data with numerical optimization techniques.
In this article, we present an overview on the thermocatalytic reaction of hydrogen peroxide (H₂O₂) gas on a manganese (IV) oxide (MnO₂) catalytic structure. The principle of operation and manufacturing techniques are introduced for a calorimetric H₂O₂ gas sensor based on porous MnO₂. Results from surface analyses by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) of the catalytic material provide indication of the H₂O₂ dissociation reaction schemes. The correlation between theory and the experiments is documented in numerical models of the catalytic reaction. The aim of the numerical models is to provide further information on the reaction kinetics and performance enhancement of the porous MnO₂ catalyst.
Wind is closely associated with the discussion of fairness in ski jumping. To counter-act its influence on the jump length, the International Ski Federation (FIS) has introduced a wind compensation approach. We applied three differently accurate computer models of the flight phase with wind (M1, M2, and M3) to study the jump length effects of various wind scenarios. The previously used model M1 is accurate for wind blowing in direction of the flight path, but inaccuracies are to be expected for wind directions deviating from the tangent to the flight path. M2 considers the change of airflow direction, but it does not consider the associated change in the angle of attack of the skis which additionally modifies drag and lift area time functions. M3 predicts the length effect for all wind directions within the plane of the flight trajectory without any mathematical simplification. Prediction errors of M3 are determined only by the quality of the input data: wind velocity, drag and lift area functions, take-off velocity, and weight. For comparing the three models, drag and lift area functions of an optimized reference jump were used. Results obtained with M2, which is much easier to handle than M3, did not deviate noticeably when compared to predictions of the reference model M3. Therefore, we suggest to use M2 in future applications. A comparison of M2 predictions with the FIS wind compensation system showed substantial discrepancies, for instance: in the first flight phase, tailwind can increase jump length, and headwind can decrease it; this is opposite of what had been anticipated before and is not considered in the current wind compensation system in ski jumping.