Article
Refine
Year of publication
Institute
- Fachbereich Energietechnik (598) (remove)
Has Fulltext
- no (598) (remove)
Language
- English (355)
- German (241)
- Multiple languages (1)
- Dutch (1)
Document Type
- Article (598) (remove)
Keywords
- Earthquake (4)
- Antibias (1)
- Artificial intelligence (1)
- BIM (1)
- Basisisolierung (1)
- Bauwerksüberwachung (1)
- Behaviour factor q (1)
- Bemessung (1)
- Cardiovascular MRI (1)
- Civil engineering (1)
The performance and biomass yield of the perennial energy plant Sida hermaphrodita (hereafter referred to as Sida) as a feedstock for biogas and solid fuel was evaluated throughout one entire growing period at agricultural field conditions. A Sida plant development code was established to allow comparison of the plant growth stages and biomass composition. Four scenarios were evaluated to determine the use of Sida biomass with regard to plant development and harvest time: (i) one harvest for solid fuel only; (ii) one harvest for biogas production only; (iii) one harvest for biogas production, followed by a harvest of the regrown biomass for solid fuel; and (iv) two consecutive harvests for biogas production. To determine Sida's value as a feedstock for combustion, we assessed the caloric value, the ash quality, and melting point with regard to DIN EN ISO norms. The results showed highest total dry biomass yields of max. 25 t ha⁻¹, whereas the highest dry matter of 70% to 80% was obtained at the end of the growing period. Scenario (i) clearly indicated the highest energy recovery, accounting for 439 288 MJ ha⁻¹; the energy recovery of the four scenarios from highest to lowest followed this order: (i) ≫ (iii) ≫ (iv) > (ii). Analysis of the Sida ashes showed a high melting point of >1500 °C, associated with a net calorific value of 16.5–17.2 MJ kg⁻¹. All prerequisites for DIN EN ISO norms were achieved, indicating Sida's advantage as a solid energy carrier without any post-treatment after harvesting. Cell wall analysis of the stems showed a constant lignin content after sampling week 16 (July), whereas cellulose had already reached a plateau in sampling week 4 (April). The results highlight Sida as a promising woody, perennial plant, providing biomass for flexible and multipurpose energy applications.
Stored and cooled, highly-charged ions offer unprecedented capabilities for precision studies in the realm of atomic, nuclear structure and astrophysics[1]. After the successful investigation of the 96Ru(p,7)97Rh reaction cross section in 2009[2], the first measurement of the 124Xe(p,7)125Cs reaction cross section has been performed with decelerated, fully-ionized 124Xe ions in 2016 at the Experimental Storage Ring (ESR) of GSI[3]. Using a Double Sided Silicon Strip Detector, introduced directly into the ultra-high vacuum environment of a storage ring, the 125Cs proton-capture products have been successfully detected. The cross section has been measured at 5 different energies between 5.5AMeV and 8AMeV, on the high energy tail of the Gamow-window for hot, explosive scenarios such as supernovae and X-ray binaries. The elastic scattering on the H2 gas jet target is the major source of background to count the (p,7) events. Monte Carlo simulations show that an additional slit system in the ESR in combination with the energy information of the Si detector will enable background free measurements of the proton-capture products. The corresponding hardware is being prepared and will increase the sensitivity of the method tremendously.
The longitudinal voltage of cable tubes with a screening mesh caused by partial lightning currents
(1989)
The proposed Den Haag Zuidwest district heating system of the city of The Hague consists of a deep doublet in a Jurassic sandstone layer that is designed for a production temperature of 75 °C and a reinjection temperature of 40 °C at a flow rate of 150 m3 h−1. The prediction of reservoir temperature and production behavior is crucial for success of the proposed geothermal doublet. This work presents the results of a study of the important geothermal and geohydrological issues for the doublet design. In the first phase of the study, the influences of the three-dimensional (3D) structures of anticlines and synclines on the temperature field were examined. A comprehensive petrophysical investigation was performed to build a large scale 3D-model of the reservoir. Several bottomhole temperatures (BHTs), as well as petrophysical logs were used to calibrate the model using thermal conductivity measurements on 50 samples from boreholes in different lithological units in the study area. Profiles and cross sections extracted from the calculated temperature field were used to study the temperature in the surrounding areas of the planned doublet. In the second phase of the project, a detailed 3D numerical reservoir model was set up, with the aim of predicting the evolution of the producer and injector temperatures, and the extent of the cooled area around the injector. The temperature model from the first phase provided the boundary conditions for the reservoir model. Hydraulic parameters for the target horizons, such as porosity and permeability, were taken from data available from the nearby exploration wells. The simulation results are encouraging as no significant thermal breakthrough is predicted. For the originally planned location of the producer, the extracted water temperature is predicted to be around 79 °C, with an almost negligible cooling in the first 50 years of production. When the producer is located shallower parts of the reservoir, the yield water temperatures is lower, starting at ≈76 °C and decreasing to ≈74 °C after 50 years of operation. This comparatively larger decrease in temperature with time is caused by the structural feature of the reservoir, namely a higher dip causes the cooler water to easily move downward. In view of the poor reservoir data, the reservoir simulation model is constructed to allow iterative updates using data assimilation during planned drilling, testing, and production phases. Measurements during an 8 h pumping test carried out in late 2010 suggest that a flow rate of 150 m3 h−1 is achievable. Fluid temperatures of 76.5 °C were measured, which is very close to the predicted value.
Cryopumps without liquid nitrogen shielding are used to provide a vacuum of 10−6 torr in the spectrometer. The vacuum system is subdivided in three sections that can be separated by valves.
The first section (scattering chamber) has a volume of 60 l, two rotation transmissions with 35 cm dia and a sliding seal that allows a rotation of 160° without deteriorating the vacuum. The second section includes the vacuum chambers inside the magnets with 6 × 80 cm cross-section and a length of 1200 cm. The third section (detector box) has a volume of 4300 l and contains a moveable detector system. The gas inside the detector with a pressure of 760 torr is separated from the vacuum by a 15 μm mylar foil with an area of 300 cm2. The detector box can be valved off by a valve with the dimension of 10 × 100 cm.
The layout of system is given. The instrumentation and the interlock system are described. First experiences with this system are presented.
With proven impact of statistical fracture analysis on fracture classifications, it is desirable to minimize the manual work and to maximize repeatability of this approach. We address this with an algorithm that reduces the manual effort to segmentation, fragment identification and reduction. The fracture edge detection and heat map generation are performed automatically. With the same input, the algorithm always delivers the same output. The tool transforms one intact template consecutively onto each fractured specimen by linear least square optimization, detects the fragment edges in the template and then superimposes them to generate a fracture probability heat map.
We hypothesized that the algorithm runs faster than the manual evaluation and with low (< 5 mm) deviation. We tested the hypothesis in 10 fractured proximal humeri and found that it performs with good accuracy (2.5 mm ± 2.4 mm averaged Euclidean distance) and speed (23 times faster). When applied to a distal humerus, a tibia plateau, and a scaphoid fracture, the run times were low (1–2 min), and the detected edges correct by visual judgement. In the geometrically complex acetabulum, at a run time of 78 min some outliers were considered acceptable. An automatically generated fracture probability heat map based on 50 proximal humerus fractures matches the areas of high risk of fracture reported in medical literature.
Such automation of the fracture analysis method is advantageous and could be extended to reduce the manual effort even further.
The adsorption of fluor-carbon complexes on GaAs(110) studied by electron energy loss spectroscopy
(1986)
Die PIA GmbH prüft seit fast 8 Jahren die Standsicherheit von Behältern für Kleinkläranlagen. Diese bestehen in der Regel aus Kunststoff oder Beton und müssen über ihre gesamte Lebensdauer den Beanspruchungen aus Handhabung, Einbau und Betrieb standhalten. Die Standsicherheit kann nach EN 12566 wahlweise durch einen rechnerischen Nachweis oder durch einen praktischen Nachweis wie die Bruchlastprüfung oder die Prüfung in der Grube erfolgen.
Eine seismische Anregung verursacht in einem Flüssigkeitstank einen kombinierten Spannungszustand, was zu einem Stabilitätsversagen der häufig sehr dünnwandigen Konstruktionen führen kann. Für die Durchführung von Stabilitätsnachweisen stehen verschiedene Verfahren zur Verfügung. Üblicherweise werden aus Gründen der Einfachheit spannungsbasierte Verfahren angewendet. Diese sind für Einheitslastfälle experimentell abgesichert, wobei eine Übertragung auf kombinierte Spannungszustände wie im Erdbebenfall nur begrenzt möglich ist. Alternativ kann ein globales, numerisches Konzept, das LBA/MNA-Verfahren, angewendet werden. Das Verfahren kombiniert eine materiell nichtlineare Berechnung (MNA) mit einer linearen Beulanalyse (LBA) und erfasst die Interaktion verschiedener gleichzeitig auftretender Beanspruchungen implizit im Nachweis. Dieser Beitrag demonstriert die Anwendung der Verfahren am Beispiel verschiedener Tankgeometrien mit Höhe/Radius-Verhältnissen zwischen 1 ≤ H/R ≤ 2 und Radius/Tankwand-Verhältnissen zwischen 500 ≤ R/t ≤ 1000 und diskutiert zusätzlich die Defizite der spannungsbasierten Nachweisverfahren.
Speicher statt Kohle. Integration thermischer Stromspeicher in vorhandene Kraftwerksstandorte
(2019)
Solares Kochen
(1990)
Simulation and measurement of melting effects on metal sheets caused by direct lightning strikes
(1991)
Simulating the electromagnetic‐thermal treatment of thin aluminium layers for adhesion improvement
(2015)
A composite layer material used in packaging industry is made from joining layers of different materials using an adhesive. An important processing step in the production of aluminium-containing composites is the surface treatment and consequent coating of adhesive material on the aluminium surface. To increase adhesion strength between aluminium layer and the adhesive material, the foil is heat treated. For efficient heating, induction heating was considered as state-of-the-art treatment process. Due to the complexity of the heating process and the unpredictable nature of the heating source, the control of the process is not yet optimised. In this work, a finite element analysis of the process was established and various process parameters were studied. The process was simplified and modelled in 3D. The numerical model contains an air domain, an aluminium layer and a copper coil fitted with a magnetic field concentrating material. The effect of changing the speed of the aluminium foil (or rolling speed) was studied with the change of the coil current. Statistical analysis was used for generating a general control equation of coil current with changing rolling speed.
Shielding effectiveness of reinforced concrete cable ducts carrying partial lightning currents
(1998)
SHEMAT-Suite: An open-source code for simulating flow, heat and species transport in porous media
(2020)
SHEMAT-Suite is a finite-difference open-source code for simulating coupled flow, heat and species transport in porous media. The code, written in Fortran-95, originates from geoscientific research in the fields of geothermics and hydrogeology. It comprises: (1) a versatile handling of input and output, (2) a modular framework for subsurface parameter modeling, (3) a multi-level OpenMP parallelization, (4) parameter estimation and data assimilation by stochastic approaches (Monte Carlo, Ensemble Kalman filter) and by deterministic Bayesian approaches based on automatic differentiation for calculating exact (truncation error-free) derivatives of the forward code.
Semi-insulating GaAs layers grown by molecular-beam epitaxy / P. Kordos ; A. Förster ; J. Betko ...
(1995)
Mit finanzieller Unterstützung der Deutschen Gesellschaft für Mauerwerks- und Wohnungsbau e.V. (DGfM) und des Deutschen Instituts für Bautechnik in Berlin (DIBt) wurden zwei aufeinander aufbauende Forschungsvorhaben zur Verbesserung der seismischen Nachweise von Mauerwerksbauten in deutschen Erdbebengebieten durchgeführt. Zunächst wurde das seismische Verhalten von drei modernen unbewehrten Mauerwerksgebäuden in der Region Emilia Romagna in Italien während der Erdbebenserie im Jahr 2012 in Kooperation mit der Universität Pavia eingehend untersucht. Aufbauend auf den Erkenntnissen dieser Untersuchungen wurde ein verbessertes seismisches Bemessungskonzept für unbewehrte Mauerwerksbauten erarbeitet. Der Beitrag stellt die wesentlichen Ergebnisse dieser Forschungsarbeiten und deren Eingang in die Normung vor.